Installation manual
© Hills Industries 2009  Page 32 
Feature 21    Zone Area Select - Zones 9-16 
Feature 21 is used to select the area(s) that zones 9-16 reside in. A zone may reside in any combination of the eight areas. 
If a burglary zone resides in more than one area, it will only be active when all areas are armed. A zone that resides in 
more than one area will be reported to its lowest area. Feature 21 has 8 segments. Segment 1 corresponds to zone 9 and 
Segment 8 corresponds to zone 16. 
  Area 1  Area 2  Area 3  Area 4  Area 5  Area 6  Area 7  Area 8 
Segment 1 – Zone 9  (1)  2  3  4  5  6  7  8 
Segment 2 – Zone 10  (1)  2  3  4  5  6  7  8 
Segment 3 – Zone 11  (1)  2  3  4  5  6  7  8 
Segment 4 – Zone 12  (1)  2  3  4  5  6  7  8 
Segment 5 – Zone 13  (1)  2  3  4  5  6  7  8 
Segment 6 – Zone 14  (1)  2  3  4  5  6  7  8 
Segment 7 – Zone 15  (1)  2  3  4  5  6  7  8 
Segment 8 – Zone 16  (1)  2  3  4  5  6  7  8 
Feature 22 new    System Options new 
Feature 22 is used to enable various system option and reporting options. 
Segment 1   
(1) 
On if siren sounds for ‘Telephone Line Cut’ when armed 
2 
On if siren sounds for ‘Telephone Line Cut’ when disarmed 
3 
On if siren blast at arming – (A siren chirp when any area is armed) 
4 
On if siren blast at exit expiration – (A siren chirp when any area exit delay expires) 
5 
On if siren blast at closing kiss-off – (A siren chirp when any area sends a closing report) 
(6) 
On if siren limited to once per zone 
7 
On if siren sounds for any Tamper 
(8) 
On if siren blasts 1 time for key-switch and wireless arming; 2 times for disarming 
(when using NX-148E in master mode on a multi-area system, siren blasts on all area disarm) 
Segment 2   
1 
On if siren driver should be a voltage output. Off = speaker output. 
2 
On if sirens should sound on expander trouble 
3 
On if Communicator limited to once per zone 
4 
On if First to Open Last to Close Reports 
5 
On if Battery Missing Test is performed every 12 seconds 
(6) 
On if Strobe flashes for 3 seconds for key-switch and wireless arming, 6 seconds for disarming 
7 
On if Manual Communicator Test performed during []-[44] test function 
(8) 
On if Box Tamper Pins on the control panel are enabled 
Segment 3   
(1) 
On if Box Tamper reporting enabled 
(2) 
On if AC Fail reporting enabled 
(3) 
On if Low Battery reporting enabled 
(4) 
On if Aux Power Over-current reporting enabled 
(5) 
On if Siren Supervision reporting enabled 
(6) 
On if Telephone Line Cut reporting enabled 
7 
Reserved 
(8) 
On if Expander Trouble reporting enabled 










