Installation manual
© Hills Industries 2009  Page 33 
Segment 4   
(1) 
On if Fail To Communicate report enabled 
2 
On if Log Full report enabled 
(3) 
On if Auto-test report enabled 
(4) 
On if Start/End programming report enabled 
(5) 
On if End Download report enabled 
(6) 
On if Sensor Low Battery report enabled 
(7) 
On if Sensor Missing report enabled 
8 
On if Expander Module (number) to be reported via the Contact I.D. report 
Segment 5 new 
(1) 
On enable Lost Clock service light 
2 
On enables Zone Doubling 
3 new 
On disables all hardwired zones on the main board. 
Must cycle power on/off to disable or re-enable hardwire zones. 
4 
On will enable all Dual End of Line (DEOL) resistors on all zones 
5 
On will prevent force armed zones to report bypass 
6 
On enables Silent Exit option 
7 new 
Reserved 
8 
On will Auto Partial Arm Area 1 
Segment 6 new 
1 new 
Enable Two Wire Smoke 
2 new 
Reserved 
3 new 
Enable Zone Inactivity Time In Hours. Default is off = days. 
4 new 
Reserved 
5 new 
Enable DC Operation 
6 new 
Reserved 
7 new 
Enable Steady (Temporal) Siren. Default is off = Evacuation Siren for fire events. 
8 new 
Reserved 
Segment 7 new 
1 new 
Reserved 
2 new 
Reserved 
3 new 
Reserved 
4 new 
Reserved 
5 new 
Reserved 
6 new 
Reserved 
7 new 
Reserved 
8 new 
Reserved 
System Option Descriptions 
Auto Partial Arm Area One 
If enabled, area one will auto partial arm at the auto-arm time. If this option is enabled, area one cannot be auto-armed in 
the full mode (see F 22 – Seg 5 – Op 8). 
Battery Testing 
The Hills Reliance can test for the presence of the battery every 12 seconds (see F 22 – Seg 2 – Op 5). 
The Hills Reliance will also test the battery condition at disarm, once per 24 hour cycle. 
Box Tamper 
If enabled, the Hills Reliance will use the N/C Box Tamper pins provided on the main board (see F 22 – Seg 2 – Op 8). 
Dual End Of Line (Zone Tamper) 
If enabled, the Hills Reliance will monitor all zones except types 17 and 28 for Dual End Of Line. A short or open circuit on a 
DEOL will set zone tamper alarms. Refer to the terminal wiring diagram for more detail (see F 22 – Seg 5 – Op 4). 
To reset tamper condition press []-[7] on code pad. 