Installation manual
© Hills Industries 2009  Page 38 
Auxiliary Output Logic Selection new 
Data  Logic 
0  Event A or Event B 
1  Event A and Event B 
2 Not Event A or Event B 
3 Not Event A and Event B 
4  Event A or Not Event B 
5  Event A and Not Event B 
6 Not Event A or Not Event B 
7 Not Event A and Not Event B 
Auxiliary Output Event Selection 
Data  Event  Data  Event 
0 
Burglary Alarm 
28 
Expander Trouble 
1 
Fire Alarm 
29 
Dynamic Battery Test Time 
2 
24 Hour Alarm 
30 
Open Period 
3 
Trouble Alarm 
31 
Closed Period 
4 
Tamper Alarm 
32 
Listen-In 
5 
Yelping Siren 
33 
Line Seizure 
6 
Steady Siren 
34 
Reserved 
7 
Any Siren 
35 
Fail To Communicate 
8 
Any Bypass 
36 
Telephone Line Fault 
9 
AC Fail 
37 
Program Mode 
10 
Low Battery 
38 
Download In Process 
11 
Duress 
39 
Smoke Reset (only for Reliance 8) 
12 
Aux 1 Code Pad Zone 
40 
Short Circuit 
13 
Aux 2 Code Pad Zone 
41 
Box Tamper 
14 
Panic Code Pad Zone 
42 
Siren Tamper 
15 
Code Pad Tamper 
43 
Any Open 
16 
Auto-test 
44 
Any Short 
17 
Alarm Memory 
45 
Any Fault (open/short on non-fire zone) 
18 
Entry 
46 
Any Alarm 
19 
Exit 
47 
Beeping Code Pad 
20 
Entry or Exit 
48 
Code Entry (see note below) 
21 
Armed State 
49 
ITI Keyfob Light Key (function 1) 
22 
Disarmed State 
50 
ITI Keyfob * Key (function 2) 
23 
Ready  
51 
Strobe 
24 
Not Ready 
52 new 
True (always on) 
25 
Fire 
53 new 
False (always off) 
26 
Fire Trouble 
54 new 
Door Unlocked 
27 
Chime  
55 new 
Access Alarm (e.g. see F68-Seg4-Op4) 