Installation manual
© Hills Industries 2009  Page 39 
Note: When event 48 is programmed, it is possible to program a user code's authorization to select which output(s) a 
particular code will activate. When LED 8 is on for an authorization, then LEDs 1- 4 correspond to that code activating 
outputs 1 - 4 respectively. Refer to the code pad programming section in this manual. 
Feature 32    Auto-Test Control 
Segments 1-4  1  168  03  00 
Segment 1 
Program a ’0’ if the intervals are in hours. ‘1 - 8’ if in days. 
1 = SUN, 2=MON, 3=TUE, 4=WED, 5=THU, 6=FRI, 7 = SAT and 8 = DAILY 
Segment 2  Program the Auto-test hourly interval from 1-255 hours, if Segment 1 is set to 0 
Segment 3  Program the Auto-test report hour in 24 hour format, ignored if Segment 1 is set to 0 
Segment 4  Program the Auto-test report time, number of minutes after the hour 
Feature 33 new    Opening Time / Auto Disarm Time 
Segments 1-2 
Hours – 08  Minutes – 00 
Feature 33 determines the start of the Open Window (in 24 hour format) and the end of the Close Window. This is the time 
when the panel would normally be disarmed. If Auto Disarm is programmed then this is the time the panel will disarm the 
selected areas on those days programmed in Feature 35. 
At this time it also enables codes with ‘Arm Only After Close Window’ authority to arm and disarm the panel. 
Note: Opening time must be earlier than closing time for Aux. outputs, or Code Authorization to function properly. 
Feature 34    Closing Time / Auto-Arm Time 
Segments 1-2 
Hours – 20  Minutes – 00 
Feature 34 determines the end of the Open Window (in 24 hour format) and the start of the Close Window. This is the time 
when the panel would normally be armed. If Auto-Arm is programmed then this is the time the panel will arm the selected 
areas. At this time, the Code Pad will beep for 50s before the panel arms. Stop/Delay the auto-arm for 45 minutes by 
entering a valid code on the Code Pad. See Feature 36. 
At this time it also prevents codes with ‘Arm Only After Close Window’ authority from disarming the panel. 
Note: Closing time must be later
 than opening time for Aux. outputs, or Code Authorization to function properly. 
Feature 35    Days Open / ‘Arm Only After Close Window’ Authority 
Feature 35 selects which days of the week each area is open. Segment 1 is for area 1, and Segment 8 is for area 8. 
Together with F33 and F34, this determines the normal operating hours of the site also known as the Open Window, when 
each area would normally be disarmed. The period outside of this time and selected days is known as the Close Window 
when each area would normally be armed. If a day is not selected then that entire day will be in the Close Window. If Auto-
Arm is programmed, the panel will attempt to arm specified areas during the Close Window. Also see F33, 34 and 36. 
Also on these selected days, user codes with ‘Arm Only After Close Window’ authority will be able to arm and disarm during 
the Close Window. On days not selected here, codes with ‘Arm Only After Close Window’ authority will not disarm. Note 
that Feature 36 can re-arm an area even after a user disarms that area if it is during the Close Window. 
Segments 1-8  Areas 1 – 8 
(1) 
‘Arm only after close window’ will arm/disarm on Sunday, and Area is open on Sunday 
(2) 
‘Arm only after close window’ will arm/disarm on Monday, and Area is open on Monday 
(3) 
‘Arm only after close window’ will arm/disarm on Tuesday, and Area is open on Tuesday 
(4) 
‘Arm only after close window’ will arm/disarm on Wednesday, and Area is open on Wednesday 
(5) 
‘Arm only after close window’ will arm/disarm on Thursday, and Area is open on Thursday 
(6) 
‘Arm only after close window’ will arm/disarm on Friday, and Area is open on Friday 
(7) 
‘Arm only after close window’ will arm/disarm on Saturday, and Area is open on Saturday 
(8) 
Reserved 