Installation manual
© Hills Industries 2009  Page 43 
Feature 48    Area 5 – Option and Report Selections 
Feature 48 is used to enable certain options that can be accessed or are visible to the user from the code pad of the 
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 5. 
If the option selection feature for any area is left blank, that area will use Feature 16 for the option selection. Refer 
to Feature 39 in this section for options table. 
Feature 49 new    Area 5 – Entry / Exit Timers 
  Entry Time 1  Exit Time 1  Entry Time 2  Exit Time 2 
Segments 1-6  30  60  30  60 
Reserved new  Reserved new 
Feature 49 sets the primary and secondary entry / exit times for area 5. If all segments in this feature are set to ‘0’, the 
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds 
Feature 50 new    Area 6 – Account Code 
Segments 1-6  10  10  10  10  Reserved new  Reserved new 
Feature 50 contains the account code sent when area 6 is reported. If Feature 50 is left as default (all ‘10’s), then the 
system account code (Feature 5) will be used. 
Feature 51    Area 6 – Option and Report Selections 
Feature 51 is used to enable certain options that can be accessed or are visible to the user from the code pad of the 
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 6. 
If the option selection feature for any area is left blank, that area will use Feature 16 for the option selection. Refer 
to Feature 39 in this section for options table. 
Feature 52 new    Area 6 – Entry / Exit Timers 
  Entry Time 1  Exit Time 1  Entry Time 2  Exit Time 2 
Segments 1-6  30  60  30  60 
Reserved new  Reserved new 
Feature 52 sets the primary and secondary entry / exit times for area 6. If all segments in this feature are set to ‘0’, the 
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds 
Feature 53 new    Area 7 – Account Code 
Segments 1-6  10  10  10  10  Reserved new  Reserved new 
Feature 53 contains the account code sent when area 7 is reported. If Feature 53 is left as default (all ‘10’s), then the 
system account code (Feature 5) will be used. 
Feature 54    Area 7 – Option and Report Selections 
Feature 54 is used to enable certain options that can be accessed or are visible to the user from the code pad of the 
system. In addition, certain communicator reports are enabled. Each of these options can be enabled by area 7. 
If the option selection feature for any area is left blank, that area will use Feature 16 for the option selection. Refer 
to Feature 39 in this section for options table. 
Feature 55 new    Area 7 – Entry / Exit Timers 
  Entry Time 1  Exit Time 1  Entry Time 2  Exit Time 2 
Segments 1-6  30  60  30  60 
Reserved new  Reserved new 
Feature 55 sets the primary and secondary entry / exit times for area 7. If all segments in this Feature are set to ‘0’, the 
entry / exit time for this area will follow area 1 (Feature 17). Valid entries are 10-255 seconds. 