Installation manual
© Hills Industries 2009  Page 54 
Feature 155 new    Days of the Week for Auto Disarm Areas 1 - 8 
Feature 36 selects which days of the week each area will auto disarm at the Opening Time. Segment 1 is for area 1, and 
Segment 8 is for area 8. 
Use this feature with caution, ensure you have programmed the Open Window correctly (Feature 33, 34, 35).
Segments 1-8  Areas 1 – 8 
1 
Auto Disarming on Sunday 
2 
Auto Disarming on Monday 
3 
Auto Disarming on Tuesday 
4 
Auto Disarming on Wednesday 
5 
Auto Disarming on Thursday 
6 
Auto Disarming on Friday 
7 
Auto Disarming on Saturday 
8 
Reserved 
Feature 162 new    EOL Resistor Value Select 
Segment 1 
0 
Feature 162 is used to select the value of resistor that is used as the End Of Line monitoring for the zones. Only applies to 
hardwire zones on main panel (address 0). Note that this feature does not work when the panel has zone doubling 
enabled and does not apply to zone expanders. 
Data  EOL Resistor Value 
0 3K3 
1 1K5 
2 2K2 
3 3K9 
4 4K7 
5 5K6 
6 6K8 