Installation manual
© Hills Industries 2009  Page 56 
Appendix 2: Reporting Fixed Codes in Contact I.D. 
The table below lists the CID event codes sent for the following reports (if enabled). The number in brackets following the 
event is the number that will be reported as the zone number if extended Contact I.D. is enabled in the system options. 
Otherwise zone ‘0’ will always be reported. If there are no parentheses, the zone will be reported as ‘0’. 
Report 
Contact I.D. 
Event 
Manual Test 
Auto test Open (user number) 
Close (user number) 
Cancel (user number) 
Download Complete 
Start Program 
End Program 
Ground Fault 
Ground Fault Restore 
Recent Close (user number) 
Exit Error (user number) 
Event Log Full 
Fail To Communicate 
Expander Trouble 
Expander Restore 
Telephone Fault 
Telephone Restore 
Siren Tamper 
Siren Restore 
Aux Power Over Current 
Aux Power Restore 
Low Battery 
Low Battery Restore 
AC Fail 
AC Restore 
Box Tamper 
Box Tamper Restore 
Code Pad Tamper 
Code Pad Panic 
Duress 
Code Pad Fire 
Code Pad Medical 
RF Sensor Lost (zone number) 
RF Sensor Restore (zone number) 
Sensor Low Battery (zone number) 
Sensor Battery Restore (zone number) 
Zone Trouble (zone number) 
Zone Trouble Restore (zone number) 
Zone Tamper (zone number) 
Zone Tamper Restore (zone number) 
Zone Bypass (zone number) 
Bypass Restore (zone number) 
Zone Inactivity 
Late To Close 
Forced Door 
601 
602 
401 
406 
412 
627 
628 
310 
310 
401 
457 
605 
354 
333 
333 
351 
351 
321 
321 
312 
312 
309 
309 
301 
301 
137 
137 
137 
120 
121 
110 
100 
381 
381 
384 
384 
380 
380 
137 
137 
570 
570 
391
 new 
454 new 
423 new 