Installation manual
© Hills Industries 2009  Page 58 
NX-408E / NX-416E / NX-448E Wireless Receiver Address Settings 
Module 
Number 
Reported 
Switch 1  Switch 2  Switch 3  Switch 4 
1
st
 32 ON  OFF  ON  OFF 
2
nd
 33 OFF ON  ON  OFF 
3
rd
 34 ON  ON  ON  OFF 
4
th
 35 OFF OFF OFF OFF 
5
th
 36 ON  OFF OFF OFF 
6
th
 37 OFF ON  OFF OFF 
7
th
 38 ON  ON  OFF OFF 
8
th
 39 OFF OFF ON  OFF 
NX-507E / NX-508E Relay / Output Expanders 
Module 
Number 
Reported 
Switch 1  Switch 2  Switch 3  Switch 4 
1
st
 24 ON  ON  OFF 
2
nd
 25 OFF OFF ON 
3
rd
 26 ON  OFF  ON 
4
th
 27 OFF ON  ON 
5
th
 28 ON  ON  ON 
6
th
 29 OFF OFF OFF 
7
th
 30 ON  OFF OFF 
8
th
 31 OFF ON  OFF 
When 
set to 
OFF 
disables 
tamper 
feature 
Max no. of 
NX-507E / NX-508E 
modules supported 
Reliance 8 = 3 
Reliance 12\128 = 8 
NX-320 Remote Power Supply 
Module 
Number 
Reported 
Switch 1  Switch 2  Switch 3 
1
st
 84 OFF OFF OFF 
2
nd
 85 ON  OFF OFF 
3
rd
 86 OFF ON  OFF 
4
th
 87 ON  ON  OFF 
5
th
 88 OFF OFF ON 
6
th
 89 ON  OFF  ON 
7
th
 90 OFF ON  ON 
8
th
 91 ON  ON  ON 
Recommendation 
It is highly advised to disconnect all power (incl backup battery) from the panel before connecting new expander modules, 
on power up the control panel will enrol modules. Next enter program mode and default the new module: 
[] 8 [Program Code] [Module Number] # 9 1 0 # [Exit] [Exit] [Wait 10 seconds] the module is now ready to be 
used/programmed. 