Specifications

LCD KEYPAD  17 
 [new user code] 
       
Prompts for a user number. Repeat steps 3 and 4 
if another user code needs to be programmed. 
 Keypad will beep 3 times if code is rejected. 
 # while display is prompting 
for a user number. 
       
Exits and saves data. 
7m. ASSIGNING AUTHORITY LEVEL 
 You must have authority to the partition you wish to add or remove from another person’s authority. 
ACTION    RESULT 
   
       
Prompts “Please Enter Your Code". 
 [master code] 
       
Prompts for a user number. 
 [user code] 
2-digit ID if NX-4, NX-4V2, NX-6, 
NX-6V2, NX-8, NX-8V2, NX-8-CF 
3-digit ID if NX-8E, NX-8E-CF (use 
leading zeros!! (i.e.  for user 7)
       
Prompts through the following list of attributes. 
Outputs used?   
If NO…    If YES… 
Master code?    Output 4 enable? 
Sched arm only?    Output 3 enable? 
Arm only?    Output 2 enable? 
Reserved    Output 1 enable? 
  Open / Close Rprt?
 Bypass enable?   
 Arm / Disarm?   
 [partition number] 
       
 Default allows access to ALL partitions. 
The first keypress will remove access to the 
partition. To reestablish access, press the partition 
number again. 
  
       
Saves data. Prompts for next user code. Return to 
step 3 to program another user code. 
 # 
       
Exits this mode. 
NOTE TO INSTALLER: Any master arm/disarm code can add or change a user code if the master 
code has access to the same partitions as the code being added/changed. Consequently, when 
programming the user codes for a partitioned system, leave at least one code access to all 
partitions or you will not be able to add new users (can be "go to program code" if enabled in 
location 43 of the control panel). If you desire the end user to be able to add new codes, you must 
remove the partition authority from all blank codes. 