User's Manual

Install the FiberJACK ONT
Zhone 2800 Series FiberJACK ONT Hardware Installation Guide
39
Installation precautions
WARNING! Installing electrical wires, especially for the AC
installations, may be hazardous and could lead to serious injury
or possibly death. Disconnect power before conducting the
installation. Take all proper precautions or have a qualified
electrician perform the tasks for installing electrical wiring.
Maximum operating temperature should not exceed the range of 0° C to 40° C
(32° F to
104° F).
Ensure that proper cable grades are used for all system and network
connections. For best results, use the cables and connectors recommended in
this document.
Connect the system to the power supply circuit as described in this document.
Before making fiber connections, be sure that the optical cable fiber tips and
components are clean and free of dust and debris. Follow established cleaning
procedures if required.
Resilient, Bend-Insensitive Fiber Optic Cabling such as the Corning 4.8mm
ClearCurve™ ZBL Drop Cable must be run to the box. This type of fiber has
<0.1dB loss for a 5mm radius loop.
Note: Sharp bends in non-bend-insensitive fiber cables create
undesirable optical attenuation or loss. A minimum bend radius of 30
mm (1.2 in) is recommended for stripped fiber so
non-bend-insensitve fiber is not sufficient for use with the Zhone
2800 Series FiberJACK ONT.