Providing power to the wallbox
Zhone 2800 Series FiberJACK ONT Hardware Installation Guide
49
Pull the second smaller diameter heat-shrink tubing down over the end of
the other molded tubing, then apply appropriate heat to shrink the smaller
diameter piece of tubing over the end of the larger diameter piece to
present a fully-insulated AC Power pigtail connection.
This connection can be pushed into the wallbox and a wallbox cover
added if the FiberJACK ONT will be installed at a later time.
Note: The AC powered ONTs have an ONT Power Pigtail with a
male connector designed to connect to the female AC Power
Pigtail connector.
Providing power for DC powered ONTs
The DC powered FiberJACK ONT may be powered from a PoE source, or
from a 2-wire DC feed.
Provide power from a Power over Ethernet source
When powering from a PoE source, run a CAT5 or CAT6 cable from the
DC power source into the wallbox.
If the PoE cable is not terminated, follow local practices to attach an
RJ-45 connector. See RJ-45 DC Power over Ethernet connection on page
52 for pinout information.
The terminated PoE cable fiber needs to extend 6" (150mm) from the
wall.
When powering from a 2-wire DC source, run a low-voltage 2-wire cable
from the DC power source into the wallbox. See 2 pin DC connection on
page 52 for information.