High Definition Intelligent Auto Tracking IP Speed Dome Camera User Manual -0-
Content Chapter 1 Precautions....................................................................... 2 Chapter 2 Structure ........................................................................... 4 Chapter 3 Features ........................................................................... 5 Chapter 4 Installation Guide .............................................................. 7 Chapter5 Network Setup .................................................................
Chapter 1 Precautions ● Please read this manual carefully before installation Note: This device is powered with AC24V. Please make sure the correct the power supply before connection. Inappropriate power supply may cause severe damage. ● Handle with care In transportation and storage process, we need to prevent stress, such as severe vibration, and immersion to avoid any damage to the product.
clean the dome body. When cleaning up dirt, use dry cloth. If dirt is uneasy to remove, swab with a neutral detergent. If there is sticky dust on the lens, please use the special lens paper. ●Working Environment Speed Dome Environmental temperature -40℃~+60℃ Moisture <95%(Non-condensing) Atmospheric pressure 86~106KPa Power AC/DC 24V/3.
Chapter 2 Structure Wall mount ceiling mount Wall amount bracket Pendent mount bracket Protective cover Protective cover Dome body Dome body Gauge cover Gauge cover -4-
Chapter 3 Features 3.1 Features 1. Built-in Decoder ● 1.3M HD IP Speed Dome(18x)support 720P 25/30fps output. ● 1.3M HD IP Speed Dome(30x)support 720P 25/30fps output. ● 2M HD IP Speed Dome(20x)support 1080P 25/30fps output.
3.2 Function Instruction ● Focus/Rotate Auto Match Speed Dome can auto adjust pan and tilt rotation speed depending on the focus distance. ● Preset Position Setting and Calling Preset function means the speed dome can memory current pan/tilt angel, focus, zoom, ect. When need, it can be called upon directly. Our speed dome support up to 220 preset positions. ● Auto Scan Users can set the left and right boundaries by control keyboard. Then speed dome can scan between it. It can set up to 8 groups scan path.
Chapter 4 Installation Guide 4.1 Preparation 1. Tools: Please prepare the necessary tools according to specific situations 2. Check installation space and address Check the space is enough to install the speed dome. The wall must be thick enough to install the expansion screws and can bear 4 times the weight of the dome camera itself. 3. Please well keep the whole package After open the package, please well keep them in case need to return to manufacturer if any problem.
1)Wall mount picture: 2)Ceiling mount picture ★Note: Ceiling mount can’t be installed outdoor without waterproof protection; otherwise, the speed dome will be damaged by water leaking. If any special requirement, please refer to ceiling mount outdoor installation manual as attachment. 4.2.
B A Clamp mark A Clamp mark B 4-M4X20 Captive screws -9-
Wall mount high speed dome camera dimension: Specific installation steps: Step1: Drill a whole on the wall (1) As shown on the left, to the underside of the mounting holes of the wall bracket as a template to draw drill position on the wall and drill. (2) Put 4 screws into the hole.
Rotate 90 degree Threading Raising Locking Step 3: Cable connection (see specific external line diagram) Step 4: Fix high speed dome on the wall Put the cables (including power, video cable, RS 485 and ground line) through the bracket. Then fix the speed dome base and the bracket with 4 screws and lock with ¢8 plain cushion and nut. Note: Do not let bracket suppress cable. Screw the nuts tight to avoid high speed dome camera drop.
fingers dirty transparent cover surface. 4.2.2 Ceiling mount high speed dome installation Ceiling dome drawing: Ø45 Drill on the wall Step 1 :Draw the drill location and drill on the wall. Put the cables (including power, video cable, RS 485 and ground line) through the wall and leave it here. Put expansion bolt of M8 into the hole.
socket, fix the 3 M6 X16 hexagon screw. Threading Rotate 90 degree Locking Raising Step 3: Cable connection (please refer to external connection drawing) Step4: install high speed dome camera with bracket Put the cables (including power, video cable, RS 485 and ground line) through the bracket. Then fix the speed dome base and the bracket with 4 M8 screws and lock with ¢8 plain cushion and nut. Note: do not let the bracket suppress the cable.
Step5: Tear off the protection film Peel off the protective film transparent ball cap. Note: to prevent foreign objects such as fingers dirty transparent dome surface. Note: The outdoor installation ceiling bracket is easy to cause the water leaking, for waterproofing measures, please see Annex. 4.3 External cable diagram The speed dome adopted 900mm lead wire, including: power, control (Internet), audio input, audio output, video, alarm input, alarm output and RS485 cables, and RS485 is reversed cable.
Power Cable:AC/DC24V; RS485:485AB is reversed cable; Audio Cable: Audio input and output can connect mic and speaker; Alarm Cable:Connect external alarm devices; Video line to Monitor Monitor Power line, connect AC24V Alarm input、 Output interface RS 485 line, Reserve Cable base Audio input、 Output interface Note:please refer to labels on the cables - 15 -
Chapter5 Network Setup ● Operation Requirement This system is advised to operate in the Windows XP operating system. In order to use and operate the system better, Please make sure below items setup or install correctly after this system installation. 1.Monitor resolution setup to: 1024x768 or more, color setup to Color (32 bit). Please refer to the Windows user manual or online help. 2.Please confirm install the fonts the system need in the operating system.
2. “Security-Local Internet-Custom setting”, take relative ActiveX controls and plug-ins setting to “Enable” 3.If you use Windows XP, that would add IP address of Network Video in “trust sites” (as figure 5.3): “trust sites”, input IP address, such as: http://192.168.1.2,and canceling “Require server verification (http:) for all sites in this zone”. Click “Add”, “close”. Fig. 5.3 【Notice】:After finished downloading of ActiveX, returning the security setting to “default level” 【Suggestion 2】:Use IE8 1.
Fig. 5.5 3.Modify permission setting- Enable local directory path when uploading files to a server as figure 5.6. Fig. 5.6 【Notice】:It is suggested that the setting above mentioned should be return to safe level for your IE’s safety. ● System Log-on Ensure the PC and network video equipment’s IP address in the same network segment: etc. PC is 192.168.1.1, and network video equipment is 192.168.1.2. Open IE, inputting the IP address in address bar. Then click “go to”, it’ll show up as figure 5.7 meantime.
Fig. 5.7 Input the User Name and password in the logon window on the right: Admin/1111 (correct case). It’ll link the picture after clicking “logon”. (As figure 5.8) Fig. 5.8 【Notice】: If video cannot display correctly, it is suggested to install ActiveX as < IE Setting> for one more time.
● Device Control It is used to control PTZ and lens, ex. PTZ direction, focus, zoom and contact closure such as light, power and rain brush output as figure5.9 Fig.5.9 Choose different protocol type and set device address to control different devices. Protocol(Fig 5.10): [Protocol]: Contains the following Protocols: PTZ_PELCO_D, PTZ_PELCO_P, PTZ_TC615_P, DOME_PELCO_D DOME_PELCO_P. [Protocol state]: Automatic identification.
Fig.5.10 Fig.5.11 The lens Control and subsidiary control switch (Figure 5.11): [Zoom]: Control the camera lens zoom, optical zoom and electronic zoom. [Focus]: camera electronic focusing, use Auto Focus ineffective. [Iris]: manually control iris switch. Fig.5.12 Fig.5.13 PTZ control (Figure 5.12): [SPEED]: manually adjust the rotation speed of the PTZ, adjustable from 0 to 100.
● Common parameter settings Click [General setting] to enter the General setting interface, as shown in Figure 5.14 Fig.5.14 Common settings [Channel Num]: the channel selection of the multi-channel network video equipment, such as: 4-channel network video server has 4 channels. [Set video cover area]: Check to set the video occluded region, including with the mouse to take effect after the area you want to block as shown in Figure 5.
Fig.5.15 Fig.5.16 Showing frame-rate and bit-stream information: select this option will display in the upper left corner of the interface, line of peach red font of frame rate and stream information in Figure 5.17 Fig.5.17 [Local storage path]: Click Browse, choose its path to be stored [Local video format]: Contains two kinds of local video format: H.
Video Param (Figure 5.18) Fig.5.18 [Video Quality: You can choose the video quality grade: best, better, good, average, poor. Frame Rate: PAL standard, 1, 5, 10, 15, 25 frame rate are optional. Stream types: type "pure video" or "audio video” can be selected. Prefer Mode: “frame rate" and "quality" can be selected [Rate]: the bitrate size can be adjusted from 32 to 8192Kbps. Resolution: 4CIF, VGA, 720P, 960P, 1080p, etc.
Audio parameters (Figure 5.19) Fig.5.
Video encryption (Figure 5.20) [Encryption Type]: Contains None and AES, [Encryption password]: password required [Password Confirm]: same as above Fig. 5.
PTZ Setting (Figure 5.21) Fig. 5.21 [COM]: Use the serial number selection Baudrate: 300, 2400, 4800, 9600, 19200, 38400, 115200 common baud rate optional Check digit: no test, odd test, even test optional. Data bits: 7, 8 optional Stop bits: 1, 2 optional. Work mode: protocol mode, transparent channel optional 【Channel number: Select the channel number [COM]: Select the serial number Device type: PTZ_PELCO_D, PTZ_PELCO_P, PTZ_TC615_P, DOME_PELCO_D, DOME_PELCO_P optional Address: selectable from 0 to 255.
Dome setting (Figure 5.22) Fig.5.22 [Channel number]: Select an available channel.
OSD (Figure 5.23) Fig.5.23 Channel name: superimposed channel name can be set in English and Chinese, can be set up to 32 English characters or 16 Chinese characters set up; does not support null character. Superimposing type: you can choose not superimposed, date, time, channel name, date, time + channel name. [Position]: 0 to 15 of 16 locations to choose from. Channel name position: 0 to 15 of 16 locations to choose from. [Custom coordinate]: click in video form.
Additional characters superimposed (Figure 5.24) Fig.5.24 Input additional characters need to superimpose in the box, by tick-defined coordinate, you can self-define the position of the additional characters.
OSD color (Figure 5.25) OSD type: channel name, date, additional character overlay. OSD color: white, black, red, green, and blue. Fig. 5.25 Alarm settings The motion alarm (Figure 5.26), check the "enable" box. Fig. 5.
[Channel Num]: select an existing alarm channel number in the view of the area, you can use the mouse to select the motion alarm area, otherwise defaulted full-screen; you can also drag the scroll bar to set up the sensitivity. Arming: You can select Monday, Tuesday ... Sunday, and check the check box to set up the arming period. [Link type]: optional linkage output, check the checkbox below, you can choose the alarm output channel. Loss alarm (Figure 5.27), check the "enable" box. Fig. 5.
Port alarm (Figure 5.28), check the "enable" box. In port: Select the alarm input port number. Mode set: optional closed-circuit alarm, open circuit alarm. Out port: Select the alarm output port number. Mode set: optional closed-circuit alarm, open circuit alarm. Arming: You can select Monday, Tuesday ... Sunday, and check the check box to set up the arming period. [Link type]: optional link out, check the checkbox below, you can choose the alarm output channel. Fig. 5.
Cover alarm (Figure 5.29), check the "enable" box. Fig. 5.29 【Channel number】: Select the alarm channel number. Arming: You can select Monday, Tuesday ... Sunday, and check the check box to set up the arming period.. 【Link type】Optional link to PTZ. [Link channel]: select an existing linkage alarm channel. [Link PTZ Type]: optional no link, preset position, pattern tour etc. [Number]: If you set the linkage PTZ preset, cruise path etc. set up the corresponding Alarm Server (Figure 5.
Fig.5.30 Email Alarm (Figure 5.31), check the "Email Alarm Enable” box. Fig. 5.31 [SMTP server]: Set the e-mail address of the SMTP server. [SMTP port]: Set the mail SMTP server port number.
Email account: Set up e-mail login user name. [Email password: set up the email login password. Email mode: set up a email SMTP server login mode, optional off, plain, cram-md5, digest-md5, gssapi, external, login, ntlm. [Main e-mail Address]: set up the primary address to send, also can be set up the rest of the three email addresses. [The mail subject]: Set the theme sent. Network parameters Wire setting (Figure 5.
WEB PORT (Figure 5.33) Set up WEB PORT,see Figure 5.33 Fig.5.33 Registration Center (Figure 5.34) Fig.5.
User name / password: the default value is QQ / QQQQ. [Server name]: The default value is NVSS-80, fill in the domain name registered on the DNS server. [IP1]: domain name server IP address. Port: fill in the default value 6004. [UPnP]: Select “UPnP enable”, it will support UPnP port mapping and router supports UPnP function to establish the mapping between IP and port. DDNS (5.35), check the "DDNS Enable" box. How to use: Login www.3322.org, register users. And add XXX.3322.
Select "PPPOE Enable", fill out the required information, then click “Set”. Fig.5.36 External storage SATA(see picture 5.37) Fig.5.37 【device no.
【status】:display device status 【usage】:select what the disk is used for Also you may choose part number, disk space and free space USB/SD(see picture 5.38) Fig.5.38 【device no.】:select device number 【status】:display device status 【usage】:select what the disk is used for Also it shows disk space and free space and initializes the disk. NFS(see picture 5.38) 【device no.
Fig.5.39 Record policy(see picture5.40) Fig.5.
【record status】:select suitable record status 【date selection】:set date of existing record or if select timing record you can set recording period through that. 【disconnect record】 :set if record or not in disconnection condition. Pre-recorded alarm(see picture 5.41),activated by checking of “pre-recorded alarm” Fig.5.41 【channel number】:select channel number 【alarm pre-record time】:selectable 5、10、15 second 【alarm post-record time】:selectable 10、15、30、60 second Storage policy(see picture 5.
Fig.5.42 Snapshot settings(see picture 5.
Fig.5.43 Smart analysis Parameter settings: basic parameter(see picture 5.44),check “enable” Fig.5.
【object color】:selectable red, green, yellow, blue, purple, cyan, black and white 【alarm color】:selectable red, green, yellow, blue, purple, cyan, black and white 【track length】:set track length 【detective sensitivity】:selectable high, medium and low Parameter settings: Event settings(see picture 5.45),check “enable” to activate. Fig.5.
It can display the corresponding rule number and rule name, and click “reset” can delete all alarm information. You can see details in alarm information by display of alarm information. Fig.5.46 Parameter settings:alarm settings(see picture 5.47) Fig.5.
【rule ID】:selectable 1~8 rule ID,and display rule name and event. 【schedule settings】:select Monday, Tuesday…..to Sunday, check it and set time period of schedule. 【link type】:enable to link to PTZ 【link channel】:select available linked alarm channel 【link PTZ type】:select to ignore linkage, preset, track and cruiser path 【number】: If linked PTZ type is set for preset, track and cruiser path, put number here. Advanced option Version information(see picture 5.48) Fig.5.
System information(see picture 5.49) Fig.5.49 PU settings(see picture 5.50) Fig.5.
SIP settings(picture 5.51) Fig.5.51 Access platform (picture 5.52) Fig.5.
User management(see picture 5.53) Fig.5.53 【add user】 :enter user name such as “guest” and password. And then select “authority” and click “add” to add a new user 【delete user】:select targeted user and click “delete” to delete this user 【change password】:Select the user you want to modify in the " User selection", enter the new password, click on "Change Password".
Update (see picture 5.54) Fig.5.54 You can update 2 kinds of program including .bin and .box files. Note: .bin file cannot be worked until twice updating.
Log management(see picture5.55) Fig.5.
Chapter 6 Menu Settings Call #95 preset to open menu of speed dome.
Language This speed dome provide 2 optional language including English and Chinese. You can Call #95 preset to open menu of speed dome, and move your mouse to “language settings”, press “aperture on” to enter settings and move joystick to switch English/Chinese, then press “aperture on” to confirm.
Display settings Call #95 preset to open menu and move joystick, select “display” settings”, then press “aperture on” to enter ”display settings” sub-menu, waving the joystick to move the pointer to targeted menu.
MAIN MENU ------------------------------------------Language:English DOME SETTINGS ------------------------------------------Auto Flip :ON Auto Stop Time :30Sec Menu OFF Time :5Min Tilt Angle Set :-5 Speed Level :Auto Back Exit Exit A:Auto Flip Open auto flip function B: Auto Stop Time The dome will stop PTZ move after a certain period when the stop code is not received by dome.
IDLE ACTION ------------------------------------------Time :30Sec Action :None DOME SETTINGS ------------------------------------------Auto Flip :ON Auto Stop Time :30Sec Menu OFF Time :5Min Tilt Angle Set :-5 Speed Level :Auto Back Exit A1 B1 Back Exit A1:Time Move the cursor to the "Time", Press iris on to setup "Time”, select "ON/OFF” through moving the joystick.
be North through moving the joystick. Press iris on to confirm. Camera settings 2MP camera settings: CAMERA SETTINGS ------------------------------------------Focus Mode :Auto Digital Zoom :OFF Backlight :OFF Image Freeze :OFF Zoom Speed :Middle Day Night :Auto Camera Reset :OFF Back Exit MAIN MENU ------------------------------------------Language:English Exit A B C D E F G H A.
H. Advance CAMERA SETTINGS ------------------------------------------Focus Mode :Auto Digital Zoom :OFF Backlight :OFF Image Freeze :OFF Zoom Speed :Middle Day Night :Auto Camera Reset :OFF Back Exit ADVANCED ------------------------------------------ A1 B1 C1 D1 Back Exit A1.
Move the cursor to "exposure mode", press the stop on entering the exposure mode set, rocker bottom can be set to "auto/priority/aperture priority/shutter priority/manual brightness" When the shutter priority exposure mode State, move the cursor to "shutter priority" by IRIS on entering setup mode, rocker set the shutter speed value. When aperture priority exposure mode State, move the cursor to "Aperture priority" by IRIS on entering setup mode, joystick up or down to set the aperture value.
ADVANCED ------------------------------------------ SPECIAL SETTINGS ------------------------------------------Wide Dynamic :OFF High Sensitivity :OFF Slow Exposure :OFF Image Denoise :OFF Mirror Image :OFF Aperture Setting : 00 Ir Correct : OFF Back Exit Back Exit A2 B2 C2 D2 E2 F2 G2 A2.
A. focus mode Move the cursor to "focus mode", press IRIS open to enter focus mode setting, rocker arm upper and lower automatically, select manual mode. B. Digital Zoom Move the cursor to "Digital Zoom" and click set aperture opening into the spotlight type, rocker arm up or down close, spot light, integrated and low light settings. C. Backlight compensation Switch settings. When the image brightness of the screen low, open the brightness of the backlight compensation to improve webcam. D.
value.Move the cursor to "b gain" by IRIS on entering the b gain settings mode, rocker sets b gain value。 ADVANCED ------------------------------------------ WB SETTINGS ------------------------------------------WB Mode :Auto Red Gain :210 Blue Gain :210 Back Exit Back Exit B1.
C1 Special setting ADVANCED ------------------------------------------ SPECIAL SETTINGS ------------------------------------------Wide Dynamic :OFF Digital Zoom :OFF Image Freeze :OFF Focus Limit :30cm Back Exit Back Exit A2 B2 C2 D2 A2. move the cursor to the "dynamic", set the aperture opening into a wide dynamic, rocker arm up and down to select parameters, can be set to "off/open". B2.
E1.Others ADVANCED ------------------------------------------ OTHER SETTINGS ------------------------------------------Defog Mode :OFF Defog Level :064 Elec-Stabilization :OFF Back Exit Back Exit A2 B2 C2 A2. Move the cursor to "through the fog mode", press the stop on entering through the fog mode setting, rocker arm up and down to select parameters, can be set to "1~5-level and closed". B2.
Switch settings. When the image brightness of the screen low, open the brightness of the backlight compensation to improve webcam. D. Zoom speed Move the cursor to "zoom speed", according to the aperture opening into the zoom speed setting mode, joystick up or down to select the camera's zoom speed to be set to "low", "medium", "high speed". E.
ADVANCED ------------------------------------------ WB SETTINGS ------------------------------------------WB Mode :Auto Red Gain :210 Blue Gain :210 Back Exit Back Exit A1 B1 C1 B1.
C1.Special settings ADVANCED ------------------------------------------ SPECIAL SETTINGS ------------------------------------------Wide Dynamic :OFF Sharpness :Auto Aperture_H :15 Aperture_V :15 Focus Limit : 30cm Back Exit Back Exit A2 B2 C2 D2 E2 A2. move the cursor to the "wide dynamic", set the aperture opening into a wide dynamic, rocker arm up and down to select parameters, can be set to "off/open". B2.
A:Preset positions PRESET ------------------------------------------Preset Number :001 Title Set :PRESET01 Call Delete MOTION ------------------------------------------ Back Exit Back Exit A1. preset number Move the cursor to "preset", press the stop on entering setup mode, preset, rocker, preset up and down Settings. Ball machine supports a total of 220 preset positions, 1-64%. B1.
B: Automatic scanning SCAN ------------------------------------------Scan Number :1 Title Set :SCAN1 Start Scan Speed :20 MOTION ------------------------------------------ Back Exit A1 B1 C1 D1 E1 F1 Back Exit A1. scan group Move the cursor to "scan group number" setting mode press the IRIS on entering the scan group number, rocker arm to scan up and down group Settings. Supports 8 ball leads the Group scan path. B1.
appears on the screen "press IRIS open to confirm ...".Users can operate on the dome, reaches the desired position and press the aperture opened to store the current path to the location to scan the right border. F1.
path. D1. edit sequence Move the cursor to "Edit series", press the stop on entering the cruise series Edit submenu. E1. Delete Move the cursor to "delete", press the aperture on delete cruises group cruise path.
D:Pattern PATTERN ------------------------------------------Pattern Number :001 Title Set :PATTERN 1 Start Delete MOTION ------------------------------------------ Back Exit A1 B1 C1 D1 E1 Back Exit A1. mode path group Move the cursor to "mode path group number" in Aperture opening into the path group setting mode, rocker mode path group, setting up or down.Ball machine total supporting 8 pattern path. B1.
E1. Delete Move the cursor to "delete", by IRIS on path group deletes the corresponding mode number mode path. E:Zones ZONES ------------------------------------------—Zone is not set— Zone Number : 1 Title Set :ZONE 1 Delete MOTION ------------------------------------------ Back Exit A1 B1 C1 D1 E1 F1 Back Exit A1. region indicate state information. B1.
border setting mode, appears on the screen "press IRIS open to confirm ...".Users can operate on the dome, reaches the desired position and press IRIS open-storing the current location for the area indicates that left border. E1. Set right margin Move the cursor to "set right", press the stop key to enter the area indicates that open borders to set mode, appears on the screen "press IRIS open to confirm ...".
C1. end time Set during the current session, the end time of a specified function is executed under. D1. linkage function Sets the current function performed within the time period, can be set to: no action, preset, scan, 1-8, cent, mode path 1-4 the cruise path.
Chapter 7 Specifications Power AC24V±10% Consumption Max 29.2w Manual speed 0.1°~180°(stepless) Preset precision ±0.
Chapter 8 symptom Power action, Simple Problem-solving Methods Possible causes on Solutions no Power supply is damaged or Replace the power supply not enough power No images, Power cable fault Machine is not self Line problems checking Corrected Troubleshoot line Ping the IP pathway is normal for the Self action Network parameters are not device to ensure that fall within IP and properly, set correctly, no networking control devices on the same network segment Network plugin settings are References
Chapter 9 After-sales Service The HD Network IR speed dome products, the company offers one-year warranty.
Appendix I Lightning and Surge Outdoor Dome Camera need to consider lightening, anti-surge, on the premise of ensuring electrical safety, may take the following measures: Signal transmission lines and high voltage equipment or high voltage cables must be at least 50 meters distance between; Try to choose outdoor wiring along the eaves line; For open field must be sealed steel tubes buried cabling, grounding and steel pipe, the absolute prohibition of the use of overhead wiring; In areas of
Appendix II Hoisting Construction Guide B as e m ade from s ilica gel for waterproof PVC plas tic pipe Speed dom e line acros s ins ide of PVC plas tic pipe Pendent mount bracket outdoor waterproof construction scheme I B as e m ade from s ilica gel for waterproof Speed dom e line acros s ins ide of pole Pendent mount bracket outdoor waterproof construction scheme II - 81 -
C us tom er hom em ade bent pipe bracket Speed dom e line acros s ins ide of pole Pendent mount bracket outdoor waterproofconstruction scheme III C us tom er hom em ade bent pipe bracket Speed dom e line acros s ins ide of pole Pendent mount bracket outdoor waterproofconstruction scheme IV - 82 -