Connecting to a Voltage Source 
The back panel of the modem provides a 2-position screw terminal power interface 
connector. For your convenience, the DC voltage of the input power is non-polarized. To 
meet your specific application, the modems can be powered from the following power 
sources: 
y  Model DSP19.2 (with AC-DC power converter): 90 to 265 Volts AC, 50 to 60 Hz, 
single phase or 100 to 400 VDC. The output of the converter is a 12 VDC source 
that will power the modem. 
y  Model DSP19.2-LV (DC version): 10 to 60 Volts DC. The model DSP19.2-LV 
comes with a power cord for making this connection. 
Figure 2-2 on page 10 shows the connection to the Model DSP19.2FP’s power interface 
shows the connection to the Model DSP19.2-LV’s power interface. 
WARNING: 
Before you connect a voltage source, observe the following power supply 
voltage guidelines. Otherwise, you will void your warranty if the wrong voltage 
is applied. 
y  Be sure the voltage source is within the permitted ranges shown 
above. Otherwise, your modem and any attached devices may be 
damaged. 
y  Customer-supplied cables must be suitable for the site 
environmental conditions. 
y  Screw terminals on the power interface accept 24 to 16 AWG. 
However, surge protection is effective only if there is a solidly 
earthed ground connection greater than 18 AWG. 
y  Be sure the power source is not controlled by a wall switch, which 
can be inadvertently turned off, shutting off power to the modem. 