User`s manual
Specifications 
28             User’s Manual - DSP19.2 Fast Poll Modem 
RS-232 (DTE) Interface 
Table B-2. RS-232 (DTE) Interface 
Signal Name  Modem Input/Output  DB-9 Pin  Description 
DCD Output  1 Data Carrier Detected 
RXD  Output  2  Receive Data 
TXD Input  3 Transmit Data 
SG 
⎯ 
5  Signal Ground 
DSR Output  6 Data Set Ready 
(Modem Ready) 
RTS  Input  7  Request To Send 
CTS  Output  8  Clear To Send 
RS-485 (DTE) Interface 
Table B-3. RS-485 (DTE) Interface 
RJ-11 Pin Number…  Corresponds to Signal Name  Modem Input or Output 
1 Not Used  NA 
2  RxD+  Output 
3 RxD-  Output 
4  TxD+  Input 
5 TxD-  Input 
6  Not Used  NA 
Environmental Specifications 
Operating temperature: 
-40 to + 85
o
 C 
Storage temperature: 
-40 to +125
o
 C 
Operating humidity: 
5 to 95 %, non-condensing 
Line isolation: 
 3750 V RMS 
Surge protection: 
Leased line up to 15K VA 