Installation manual
Maxsys and MX Series Software Administrator’s Guide 111
Emboss Element Properties
Use the following information to define the properties of an Emboss Element.
Emboss throughput is dependent upon module assignment per emboss 
element. Emboss module throughput is dependant on the number, location, 
font, and make-up of characters to be embossed. Multiple modules may be 
used in a system to increase system throughput by dividing lines up among 
modules. The slowest module will determine system throughput.
Advanced Tab Properties
Perform Operation 
String
These three fields are related inasmuch as the program 
performs the defined operation string using the selected Data 
Field on the selected module.
For example: If there are four modules and each module has 
a different foil type, and the operation string calls for the use 
of foil type A (which is loaded on module 3), you should 
select the options accordingly. Operation parameters are 
defined in the Data Setup.
Perform Operation 
Data Field
Perform Operation 
on Module
Clear Perform 
Operations Fields
Click Clear to remove all information from the Perform 
Operations fields.
Preceding 
Operations
Click Add/Modify to open the dialog from which you can 
select the operation(s) to occur before this operation. Use the 
arrows to move the operations from one column to the other.
Settings Tab Properties
Name The name of the Emboss Element
Side The side of the card (Front or Back) on which the operation is 
to occur
X The horizontal coordinate at which the operation is to occur. 
Click the icon to use Data Field information for the X 
coordinate.
• For Maxsys – From 0.135 inch (3.43 mm) to 3.200 inches 
(81.28 mm), measured from the left edge of card to the 
center line of the character 
• For MX Series – From 0.10 inch (2.54 mm) to 3.275 inches 
(83.19 mm), measured from the left edge of card to the 
center line of the character 
Click the icon to select Data Field information for this 
op
eration.