Installation manual
Maxsys and MX Series Software Administrator’s Guide 273
4. Se
t the data contrast.
5. Op
tionally select ICAO Specification
6. Optionally perform the confusion analysis
A. Set Confu
sion threshold
B. E
nter Confusion Data List
Filter Tab
This tab is used to define the settings that are used to convert RGB color images to 
grayscale and to modify or enhance an image for best results on products.
It is important to note that the changes made in this procedure will affect every 
image lased by the system. Ensure that the best possible image quality is being 
used and that there is a high degree of similarity (level, contrast, etc.) among all 
pictures. Verify settings with extreme image examples.
All effects from filter setting can be seen on the display if the menu item 
View | Bitmap View Type | Filtered is set in the menu.
Color to Grayscale 
Conversion Method
Select from predefined methods. Note: Previous versions 
of ConCAD used the Y-Channel from YCbCr (CCIR 601)
method as the default.
Filter Window This window contains the filters that will be applied 
during the conversion process. 
Note: The filters will occur in the order listed. 
• Select a filter from the New list and then click Add
to add the filter to the list.
• Use the arrow buttons to move the selected filter 
up or down in the list.
• To remove a filter from the list, select the filter and 
then click Remove.
• To edit the properties of a filter, select the filter and 
then click Edit or double-click on the filter in the list.
• To preview the changes being made to the image 
select the Preview checkbox.
Filter Types Resize for Laser -
 This filter may only be used one time on 
the list and will use the DPI value found on a different 
tab for the element. In general, it is only necessary to 
use the Resize for Laser filter if the Unsharp Mask filter is 
used. In this case, the Resize should occur just before the 
Unsharp Mask.