User guide

Application 73
© 2012 Datacom Systems Inc
SOLUTION: The SS-1204BT-BT-S taps the link, accepts the input from the workgroup switch and
server switch, replicates the traffic to multiple ports for analysis and utilizes the factory default
LINK PROTECT settings. With the factory default LINK PROTECT settings, if one side of the
network traffic is interrupted for longer than 10 seconds, the tap will enter bypass mode and the
other side of the network will also drop "LINK" with the integrated tap. See the SET LINK
PROTECT section for additional information. The SS-1204BT-BT-S has a built in tap on ports
1 and 2 which make copies of the traffic flowing through the unit.
CONFIGURATION: The IP address (default 192.168.1.1), Subnet Mask and Default Gateway is set
during the 'Initial Configuration' for your Local Area Network settings and will not be covered in this
section, see the 'IP Address Configuration with TELNET ' section for those steps. Use the syntax
below in the Command Line Interface (CLI) to setup Tap and Any-to-Any ports (syntax is shown
with either user > or Superuser # prompts):
For Configuration, open TELNET on your Management PC and open a hostname connection with
the SS-1204BT-BT-SMANAGEMENT RJ45 port. Settings are found in the 'Initial Configuration',
'MANAGEMENT Port Configuration (RJ45)', 'TELNET ' section.
Enter Username (default: Administrator) and Enter key. Enter Password (default: admin) and Enter
key. Default prompt is the > symbol. Enter superuser mode, type su and Enter key. Enter
Password (default: password) and Enter key. Default prompt is the # symbol. Use the following
syntax to set the input/output for Any-to-Any ports as well as the output for Tap ports.