User guide

Introduction
96-30052-001 Rev. A4 DataDirect Networks StorageScaler 8460 User Guide | 12
At the rear, the chassis assembly contains two power and cooling modules, two I/O modules,
two 5V regulators, and two LEDs (Figure 4). Refer to Section 3.1.2 "Enclosure Status LEDs"
for description of the color and status of the LEDs.
1.3 I/O Module
The two I/O modules are hot-swappable and provide a redundant path to the disks (Figure 5).
Each I/O module provides five 4-wide SAS data links. These modules communicate inter-IO
information using Ethernet through the baseboard.
There are LEDs mounted on the I/O module to indicate the status of the module. Refer to
Section 3.1.4 "I/O Module LEDs" for description of the color and status of the LEDs.
Figure 4. SS8460 Rear View
I/O Module B
PCM B
PCM A
5V Regulator B
Locate and System Fault LEDs
I/O Module A
5V Regulator A
Figure 5. An I/O Module
Power LED
Mini SAS HD
Link Fault LED
Link Established LED
Locate Beacon LED
Module OK LED
(DO NOT USE)
Host/Expansion Ports
Fault LED