Installation manual

  IQ3 Data Logger Dash Installation Manual  
36
Warnings 
The IQ3 provides the ability to program up to four individual warning channels. The face of the 
dash contains four warning lights. Each warning light is associated with a single warning 
channel. To program each individual warning channel. 
1.  Select the “Warnings” tab.  
2.   Next, left click on the warning light you would like to program. This action will open the 
Warning Light text box. 
Warning Parameter  Description 
Warning Channel  Sensor input to be used to trigger warning. 
Low Warning Limit  Sensor value to trigger warning when below this value. 
High Warning Limit  Sensor value to trigger warning when above this value. 
Channel Tag  Text to be displayed above warning channel value when warning is 
activated. 5 chars max. 
Channel Value is Inside Warning Limit 
Window 
Triggers warning when sensor value is between Low and High 
Warning limits. 
Channel Value is Outside Warning Limit 
Window 
Triggers warning when sensor value is below Low Warning Limit 
and above High Warning Limit. 
Warning Input 1 AND Warning Input 2 
Conditions Are Met 
Requires that warning 1 and warning 2 conditions are met to 
activate warning. 
Warning Input 1 OR Warning Input 2 
Conditions Are Met 
Requires that warning 1 or warning 2 conditions are met to 
activate warning. 
Warning Tag  Text displayed to the left of warning channel value(s) when 
warning is activated. 5 chars max. 
On Delay Time  Time is seconds to delay before warning is activated. 
Turn On External Warning  Turns on external warning when warning channel is activated. 
The following section provides an example warning setup. 