7.0 Configuration 
Initial device settings can be configured using the i50B Programmer utility (Windows only). This is 
available on the Datalink web page at http://www.datalinksystemsinc.com/download.html. 
Download and install the programmer, then run it using the shortcut on the Start menu in the All 
Programs/DataNet folder. Figure 3 shows the Programmer window. 
Figure 3 – i50B Programmer 
7.1 Connecting a PC to the i50 
The i50 is normally programmed through the Program connector on the front panel. See section 4.3 
for information on making a cable to connect from a PC serial port to the RJ-45 connector. Using this 
connector allows the programmer to reboot the device without removing power. This can be useful if 
the device is installed in a hidden location where it is difficult to access the power connector. In this 
case a programming cable could be left installed in the vehicle, allowing quick programming changes 
in the future. 
Firmware versions 3.95 or newer also allow programming through the COM ports on the back panel. 
The i50 will automatically scan each port during boot up to detect programming signals. 