Specifications
i50 Manual (5.10) 
Page 54 
© 2015 Datalink Systems, Inc. 
www.datalinksystemsinc.com 
14.0 Firmware Updates 
The i50 firmware can be updated by connecting a programming cable to the RJ-45 Prog connector 
on the front panel, and using the Rabbit Field Utility (RFU) program. Programming cables may be 
purchased from Datalink Systems, or made up using the pin outs defined in section 4.3. The RFU 
program is available at http://www.datalinksystemsinc.com/download.html. Figure 9 shows the 
program’s main screen. 
Figure 9 – Rabbit Field Utility 
Use the Setup menu to access the File locations screen, as shown in Figure 10. Ensure the locations 
point to the files supplied with the RFU program. 
Figure 10 – RFU file locations 
Use the Setup menu to access the communications options. Select the options as shown in Figure 
11, replacing the Serial Port setting with the correct port. Uncheck the Enable Processor Verification 
option if you have problems connecting, and check the Use USB to Serial Converter option if 
appropriate. If problems persist, try setting the Stop Bits to 1. 