15.0 Programming Settings from DataGate 
The DataGate server can send and receive individual i50 settings using the Remote Config button on 
the Asset Properties window (Modems tab). Each setting is referenced by ID, with integer and string 
values in separate lists. Many of these settings are crucial to the correct operation of the device, so 
take care when making changes. These changes can also be made by an administrator via the 
WebGate interface. 
15.1 Integer Values 
ID 
Name 
Description 
Default 
0 
I_UPDATE 
Update clock using GPS (1=Yes 0=No) 
1 
1 
I_ALARMSTATE 
Alarm state. Bits 7-5 are response state. Bits 4-1 are alarm state. Bit 0 indicates 
geofence on 
0 
2 
I_IP1 
Cellular IP address (also uses I_IP2-I_IP4). Range=0-255 
- 
3 
I_IP2 
“ 
- 
4 
I_IP3 
" 
- 
5 
I_IP4 
" 
- 
6 
I_PORTA 
PORTA (Program/COM1/WiFi) Port Setting. See note at bottom for values 
0 
7 
I_PORTB 
PORTB (COM2) Port Setting. See note at bottom for values 
0 
8 
I_PORTC 
PORTC (GPRS) Port Setting. See note at bottom for values 
0 
9 
I_PORTD 
PORTD (Iridium) Port Setting. See note at bottom for values 
0 
10 
I_PORTF 
PORTF (COM3) Port Setting. See note at bottom for values 
0 
11 
I_SATSPEED 
PDT COM Speed. See note at bottom for values 
7 
12 
I_EVENTS 
System Events (Firmware >= 4.77). Bit 2=Errors. Bit 1=Power Down. Bit 
0=Power Up 
7 
13 
I_ID1 
Unit ID (also uses I_ID2 and I_ID3). Range=0-255 
255 
14 
I_ID2 
" 
255 
15 
I_ID3 
" 
255 
16 
I_INPUT1 
Input 1 Setting. See note at bottom for values 
0 
17 
I_INPUT2 
Input 2 Setting. See note at bottom for values 
0 
18 
I_INPUT3 
Input 3 Setting. See note at bottom for values 
0 
19 
I_INPUT4 
Input 4 Setting. See note at bottom for values 
0 
20 
I_USEINPUT1 
Send events when Input 1 changes. Bit 0=Low. Bit 1=High 
0 
21 
I_USEINPUT2 
Send events when Input 2 changes. Bit 0=Low. Bit 1=High 
0 
22 
I_USEINPUT3 
Send events when Input 3 changes. Bit 0=Low. Bit 1=High 
0 
23 
I_USEINPUT4 
Send events when Input 4 changes. Bit 0=Low. Bit 1=High 
0 
24 
I_INPOLARITY1 
Input 1 polarity (0=Active Low 1=Active High) 
0 
25 
I_INPOLARITY2 
Input 2 polarity (0=Active Low 1=Active High) 
0 
26 
I_INPOLARITT3 
Input 3 polarity (0=Active Low 1=Active High) 
0 
27 
I_INPOLARITY4 
Input 4 polarity (0=Active Low 1=Active High) 
0 
28 
I_USEIGN 
Send events when IGN changes. Bit 0=Low. Bit 1=High 
0 
29 
I_OUTPUT1 
Output 1 Setting. See note at bottom for values 
32 
30 
I_OUTPUT2 
Output 2 Setting. See note at bottom for values 
32 
31 
I_OUTPUT3 
Output 3 Setting. See note at bottom for values 
32 
32 
I_OUTPOLARITY1 
Output 1 polarity (0=Low 1=High) 
1 
33 
I_OUTPOLARITY2 
Output 2 polarity (0=Low 1=High) 
1 
34 
I_OUTPOLARITY3 
Output 3 polarity (0=Low 1=High) 
1 