Magellan® 9500/9500Ω 9504/9504Ω with SmartSentry® Product Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents Chapter 1. Introduction .................................................................................... 1-1 Manual Overview ........................................................................................................1-1 How to Use This Manual .........................................................................................1-2 Scanner and Scanner/Scale Nomenclature ......................................................................1-4 Connectors .................
Viewing Angle ..................................................................................................... 2-28 Placing and Installing the Remote Scale Display ...................................................... 2-29 Changing Weighing Modes .................................................................................... 2-32 Set-Up & Installation ................................................................................................. 2-33 EAS Considerations .........................
Shift Test (Metric) ............................................................................................... 5-12 Increasing- Load Test (Phase 2) ............................................................................ 5-13 Blanking Test ..................................................................................................... 5-14 Decreasing-Load Test .......................................................................................... 5-15 Return to Zero Test ...................
EAS Deactivation Duration — Retry ....................................................................... 6-57 EAS Deactivation Duration — Manual ..................................................................... 6-58 Interface Related Features ......................................................................................... 6-59 Interface Type .................................................................................................... 6-59 Maximum Host-Transmitted Message Length ........
UPC-A Enable ......................................................................................................... 6-121 UPC-A Number System Character Transmission .................................................... 6-122 UPC-A Check Character Transmission .................................................................. 6-123 Expand UPC-A to EAN-13 ................................................................................... 6-124 UPC/EAN AIM ID .................................................
RSS-14 Check Character Transmission ................................................................. 6-176 RSS-14/EAN-128 Emulation ............................................................................... 6-177 RSS-14 2D Component Enable ............................................................................ 6-178 RSS-14 AIM ID ................................................................................................. 6-179 RSS-14 Label ID .................................................
I 2 of 5 Check Character Transmission ................................................................. 6-224 I 2 of 5 AIM ID ................................................................................................. 6-225 I 2 of 5 Label ID ............................................................................................... 6-226 I 2 of 5 Length Control ...................................................................................... 6-227 I 2 of 5 Maximum Label Length ...............
Standard Standard Standard Standard Standard Standard Standard 2 2 2 2 2 2 2 of of of of of of of 5 5 5 5 5 5 5 Label ID .................................................................................... 6-273 Length Control ........................................................................... 6-274 Maximum Label Length ............................................................... 6-275 Minimum Label Length ................................................................ 6-276 Fixed Length 1 .
DATALOGIC SCANNING, INC. MAGELLAN® END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
6.2 ing to Datalogic's standard assistance practices. Datalogic does not warrant that the product will meet End User's requirements or that use of the product will be uninterrupted or error free, or that Datalogic's remedial efforts will correct any nonconformance.
Chapter 1 Introduction This Product Reference Guide contains comprehensive instructions on how to install the scanner or scanner/scale (either model may be termed “scanner” for the purpose of simplicity in this manual), how to program it using special programming feature bar code labels, and advanced user information as described in the following overview.
Chapter 6, Programming, details procedures and provides custom bar- codes for setting programmable scanner and scanner/scale features. This chapter is organized by the categories: General Features, Interface Related Features and Symbology Related Features. Appendix A, LED/Beeper Indications & Controls, lists the various functions and indications of the scanner/scale control panel features.
Manual Overview Manual Conventions ‘NOTE’ blocks contain information that is helpful and recommended. They provide information that is critical to operations and/or procedures described in this manual. LEGAL NOTE ‘LEGAL NOTE’ blocks indicate procedures or activities which may be regulated under law by governmental agencies. It is your responsibility to ensure compliance with the regulations that govern installation of weighing devices.
Scanner and Scanner/Scale Nomenclature Controls, indicators and other nomenclature are shown in Figure 1-1. Figure 1-1.
Scanner and Scanner/Scale Nomenclature Connectors The appearance of the connector panel will vary depending upon the factory options purchased with your model. Reference Figure 1-2. Figure 1-2. Connector Panel 0.00 POS Terminal POS TERMINAL Remote Display Aux.
Physical Parameters This chapter provides specifications for performance, environmental and electrical parameters. Reference the second chapter of this manual, Site Preparation and Installation, for physical measurements of all models and some accessories. Scanning The scanner has a scan zone between the two windows where the scanner projects laser light in order to scan items.
Physical Parameters Weighing Specifications for scale capacity, settling time, minimum and maximum static weight, zeroing, and warm-up time are given below. For more information regarding the topic: Proper Weighing Technique, refer to the Operation and Maintenance chapter of this manual. Rated Weight Capacity The scale’s operational weight capacity is: • 30.00 pounds, displayed in 0.01 increments OR • 15.000 kilograms1, displayed in 0.005 increments.
Warm-Up Time There are two pertinent warm-up times that apply to the scanner or scanner/scale: The two warm-up periods can be performed concurrently, thereby reducing the total required warm-up time to 60 minutes. NOTE Thermal Equilibrium When the unit is moved from a cooler temperature (such as a storage area) to a warmer environment (such as a checkstand location), 60 minutes must be allowed to acclimate the unit to ambient conditions prior to calibration or operation.
Physical Parameters Figure 1-3.
Electrical Specifications Before installation, always verify that the site’s electrical service meets the scanner/scale’s requirements. The scanner has been engineered for compatibility with most international electrical systems operating in ranges from 100 to 240VAC at 50-60 Hz. Verify that the power source will supply “clean” electrical power to the equipment; that is, it must be free of excess electrical noise. Check the IEC power cord shipped with the scanner/scale.
Laser and Product Safety Laser and Product Safety Laser safety requirements are based on IEC Standard Publication 60825-1 (2001) and CDRH 21CFR, Chapter 1, Subchapter J and (CDRH) Laser Product Performance Standard, User information [1040.10(h)1]: • User Maintenance. No user maintenance of the system other than cleaning of the scan windows is required. • Radiant Energy. The scanner is an IEC Class 1 and CDRH IIa laser product. The system uses two embedded Class 3B Visible Laser Diodes (VLDs).
Safety precautions to be taken: No adjustments or alteration of the scanner or scanner/scale housing are to be attempted by the user. CAUTION WARNING The failure of the facet wheel motor while the unit is continuing to emit a laser beam causes the emission levels to exceed those for inherently safe operation. The unit has safeguards to prevent this occurrence.
Labeling Labeling Regulatory, reference and safety labeling is shown in Figure 1-4. Figure 1-4. Labeling III N max = 3000 Max 15 kg Min 0.1 kg e = 0.005 kg Max 30 lbs Min 0.2 lb e = 0.01 lb Or... Located on EAS Single-Antenna models n max= 3000 III emin= .01 lb NTEP: 02 - 043 AM - 5454 IEC CLASS 1 LASER PRODUCT CAPACITE 15.000 x .005 kg CAPACITY 30.00 x .01 lb +10°c to +40°c 6-0928 Class IIa Laser Product. Avoid long term viewing of direct laser light. Appareil à laser de classe IIa.
Agency Compliances The scanner and scanner/scale meets or exceeds the requirements for its device type as set forth by the following agencies and regulations: COUNTRY COMPLIANCE COMMENTS Electrical United States UL 60950 TÜV NRTL/UL Canada CAN/CSA C22.2 No.
Bar Codes Supported Bar Codes Supported The scanner can read/decode the following bar code types (symbologies): • UPC Versions A & E • UPC Supplementals and Add-ons (2 & 5 digit supplimentals, Coupon code and Code 128) • Plural Stage Dual UPC Bar Codes for Japan ( 2 label read) • Reduced Space Symbology (RSS) RSS-14, RSS expanded, RSS Stacked • EAN-8 & 13 • JAN-8 & 13 • UCC/EAN-128 • Code 39 • Code 39 full ASCII • Code 128 (including conversion to Code 39) • Code 93 • Interleaved 2 o
NOTES 1-16 Magellan® 9500
Chapter 2 Site Preparation and Installation This chapter provides a reference for preparing most checkstands to receive the scanner or scanner/scale. Included are physical parameters and instructions for checkstand preparation, power and ventilation considerations, cable routing information and unit installation. Site Preparation lists all procedures necessary to prepare the checkstand.
Figure 2-1. 9500 Models Model 9501 Model 9502 Pre-Installation Considerations It should be noted that the scope of this manual does not encompass all factors related to worker safety and checkstand design. It does, however, offer a list of considerations that may be helpful in ensuring greater safety and productivity. Careful planning using these general guidelines should result in a more efficient, comfortable work environment. The U.S.
Checkstand Design Checkstand Design 1. Select a design which allows load-sharing by several muscle groups (for example designs which allow the cashier to use both hands for scanning and bagging). 2. Select checkstands which deliver products to the cashier on an input belt and do not require the unloading of items from a cart. These designs put less stress on the cashiers’ shoulders and back. 3. Minimize the distance between the input and take-away conveyors (i.e.
Scanner Installation 1. Mount the horizontal surface of the scanner flush with the countertop to encourage slide scanning rather than lifting. 2. Position the centerline of the scanner read area 8 - 10 inches (20.3 25.4 cm) from the edge of the checkstand (cashier side). Scanner Maintenance 1. Keep scanner windows clean. This will improve productivity and reduce rescans. 2. Replace scanner glass when excessive scratches are evident.
Site Preparation Overview Develop a smooth fluid motion during scanning, sharing work equally between hands. Use the entire hand for grasping and lifting items. Since the scanner reads labels on all four sides plus the top and bottom, there is no need to turn a bar code toward either of the scanner windows. Develop efficient scanning motions, not necessarily faster hand movements. Simply slide the item across the scanner’s horizontal window with as little orientation motion as necessary.
Recommended Power Installation: Since the typical grocery envi- ronment includes conveyor belts and electric motors, care should be taken to ensure that the scanner has a supply of “clean” power (power without excessive electrical noise). A wiring diagram shows the recommended wiring that will provide the scanner with a “clean” source of power. Refer to Figure 2-4.
Ventilation and Spacing Vertical Clearance: Provision must be made to allow adequate space above the scanner bonnet for removal and replacement of the All Weighs™ Platter (the L-shaped platter). Optimal clearance permits the platter to be grasped at its top vertical edge and lifted for removal without obstruction (such as a fixed keyboard mount or any type of enclosure).
• A source of air that provides adequate cooling by convective air flow. DO NOT place the scanner in a close-fitting, fully enclosed checkstand. Provide a MINIMUM of 16 square inches (103.2 square centimeters) of air intake from below the installation for sufficient convective cooling. NOTE If motors, conveyor belts, or other heat producing equipment are located near the scanner, forced air ventilation may be required. In most installations, a 30 cfm (.
Service Access Service Access The scanner and scanner/scale have been engineered to allow performance of all routine service and maintenance (such as “zeroing” and calibration) without removing the scanner from the checkstand. Additionally all cable connections made at the scanner can be connected and removed while the unit is sitting on the countertop. The installer should provide service access to all remaining cable connectors as well as the AC/DC Power Supply (if installed).
Power Installation Reference the wiring diagram in Figure 2-4 for the recommended fusing arrangement. Grounding The AC/DC Power Supply should have an AC outlet with a clean earth ground. If you are not sure how to verify the amount of electrical noise (interference) on the power line, ask a qualified electrician to measure the input line voltage. Figure 2-4.
Checkstand Preparation Checkstand Preparation Reference Figure 2-5. When performing a first time installation into a new checkstand, verify before cutting that room will be allowed for cabling, the AC/DC Power Supply, and the Sensormatic® Controller Box. When making the opening, take extra care to accurately cut to the correct dimensions. Mounting may require installation of support(s), countertop routing, or other such devices.
Liquid Spills and Moisture Select a checkstand design which allows fluids to flow through, and directs liquids away from any electronic equipment or storage areas. Counter Cutout The most important consideration when planning the counter opening for the scanner is the operator’s comfortable reaching distance. The ideal, ergonomically sound installation allows items to be directed within easy reach, and a scanning area requiring no lifting or special orientation of items.
Counter Cutout 3. Install the AC/DC Power Supply, the Remote Scale Display cable and the interface cable(s) observing the following: Interface cables (and display cable, if applicable) should be routed away from all highly inductive electrical devices, like motors and conveyor belts, and even away from the unit’s power cable if possible. Cables should be easy to remove in the event that replacement is required. A little planning now will save a lot of frustration later. 4.
Figure 2-6. Typical Checkstand Design & Cutout Location Remote Display Conveyor POS Terminal & Printer Optional Item Diverter Deadplate 6.3" (16.
Counter Cutout Refer to Figure 2-7 for dimensional information. Figure 2-8 and Figure 2-9 provide counter cutout details for model 850x/950x interchangeability and minimum required counter cutout (for new 950x installations) respectively. Figure 2-7. Dimensions Window 7.0" (17.78cm) 8.0" (20.32cm) 8.6" (21.84cm) 13.5" (34.29cm) 6.5" (16.51cm) 17.76" (45.11cm) 11.5" (29.21cm) SCANNER 11.1" (28.19cm) PLATTER 11.9" (30.23cm) 28.9 lb. (13.1kg) 22.2 lb. (10.
Figure 2-8. Cutout Dimensions: Recommended for 8500/9500 Interchangeability 20.125" (51.12cm) 18.625" (47.30cm) Max. Radius = 0.25" (0.64cm) 4x Rail 0.75" (1.9cm) 11.625" (29.53cm) 3.0" ± .03" (7.62 ± .76mm) (Center Line) Rail 0.75" (1.9cm) If leveling feet are needed, use the placement shown here, represented with plus signs (+). 3.0" ± .03" (7.62 ± .76mm) 0.37" ± .030" (0.94 ± 0.07 cm) 0.37" ± .03" (0.94 ± 0.07 cm) 20.125" ±0.06" (51.2 ±0.15 cm) 0.375" ± 0.03" (.95 ±.08 cm) 0.75" (1.9 cm) 1.
Counter Cutout Figure 2-9. Cutout Dimensions: Minimum Required Counter Cutout 20.09 ± 0.06" (51.03 ± 0.15cm) 17.88 ± 0.06" (45.26 ± 0.015cm) Max. Radius = 0.25" (0.64cm) 4x Rail 1.22" (3.1cm) 11.562" (29.367cm) 3.0" ± .03" (7.62 ± .76mm) (Center Line) Rail 1.0" (2.54cm) If leveling feet are needed, use the placement shown here, represented with plus signs (+). 3.0" ± .03" (7.62 ± .76mm) .50" ± .030" (1.27 ±0.07 cm) 0.61" ± .03" (1.55 ±0.07 cm) 20.09" ± 0.06" (51.03 ± 0.15cm) 0.375" ± 0.03" (.
Checkstand Mounting There are a number of things to take into account when installing the unit into a checkstand. Key factors are ergonomic/worker safety, loading capacity and stability. Consider the scanner or scanner/scale’s weight when calculating the robustness of construction needed to support it as well as maximum capacity of weighed and scanned items. NOTE If you choose to rout a countertop with a thickness of 0.75” (1.
Installation Overview The following text describes each of these steps. Unpacking To unpack the unit: • Inspect the package for signs of damage that may have occurred during shipping. If damage is found, report it to your carrier immediately. • Lift out the accessory box containing the AC/DC Power Supply, optional Remote Scale Display and cable (if present), and the Quick Reference Guide. • Remove the Quick Reference Guide and familiarize yourself with the unit’s controls and features.
Figure 2-10. Remove Protective Vinyl Protective vinyl MUST be removed from the platter before use. • Proceed to the Operational Verification instructions below. Operational Verification Follow these steps to ensure that your unit has arrived undamaged and is fully functional before installing it in the counter and connecting it to your POS system. 1. Connect the scanner and the EAS antenna to the EAS Controller Box (see Figure 2-20 and Figure 2-21) and power-on the controller box. 2.
Installation Overview When power is applied to the unit, the normal indicator sequence is: • The scanner indicator (top-most, green LED) will be lit (dim) steadily. • The EAS indicator (bottom-most, tri-color LED) will flash ON/ OFF during power-up. Additionally, the 7-segment display will flash the number ‘9’. indicating the EAS system is being initialized. • If the Selftest detects a problem, the 7-segment display will display a number code.
Scanner: Pass UPC/EAN bar code labels in front of the scanner’s win- dows. Since the interface cable is not yet connected to the POS terminal, the scanner may be limited to reading only one or two labels (see the note that follows). The scanner indicates when each label has been successfully read by flashing the green scanner light and emitting a good read tone (beep). NOTE When not connected to the host, the scanner may be limited to reading only one or two labels.
Installation Overview Scale: If the Yellow (middle, scale) LED is not lit, press the Scale Zero Push Button momentarily. If the scale is operating correctly, the yellow LED will illuminate and remain on steady, and the display will show a reading of 0.00 lb (0.000 kg for metric). If the display is blank or a is displayed, it may be necessary to calibrate -0the scale before continuing. Refer to Chapter 5, Calibration, for calibration procedures. Remote Scale Display: Check to verify that 0.00 lb (0.
Diagnostic Modes Two diagnostic modes are available which allow you to initiate scanner or scale diagnostic tests, as well as verify the scanner’s ability to read bar codes. Scanner Diagnostic Mode While in Scanner Diagnostic Mode, continuous scanning of labels is allowed, permitting the user to scan an unlimited number of bar codes while troubleshooting problems. Under normal operation, the scanner stores label data, awaiting the signal which transmits it to the host.
Installation Overview Scale Diagnostic Mode To enter Scale Diagnostic Mode, press the Scale Zero Push Button for approximately four seconds. Six rapid tones will be sounded, indicating the unit is leaving normal operation and entering Scale Diagnostic Mode. The Remote Display will flash a ‘1’ across the display while the dignostic routine is being run. When diagnostics are completed successfully, the display will indicate that the unit has passed the diagnostic test by displaying PASS .
Figure 2-11.
Remote Scale Display Placement/Installation Figure 2-12 provides physical dimensions for the AC/DC Adapter (part number 8-0582). Figure 2-12. Physical Measurements: AC/DC Adapter 2.3" (5.8 cm) 3.1" (7.8 cm ) 1" 5.5 ) m c (14 Remote Scale Display Placement/Installation When installing the optional Remote Scale Display, consider both the customer’s viewing angle and the amount of daily ambient light conditions anticipated at this installation site.
Viewing Angle The optimum viewing angle is directly facing the customer. To ensure that the display is easily readable for the majority of your customers, the display should be approximately 48 to 60” (122 to 152 cm) from the floor. Check with local Weights and Measures authorities regarding proper positioning of scale displays used in retail trade. NOTE Figure 2-13. Remote Scale Display 0.
Remote Scale Display Placement/Installation NOTE The connector at the Remote Scale Display end is secured with a rubber band during shipping to prevent damage to the “locking tabs” (see Figure 2-15). After routing the cable, remove this rubber band before the cable end connecting to the Remote Scale Display head. Failure to remove the band will keep the connector from latching properly when it is connected to Remote Scale Display port.
Figure 2-14. Physical Measurements: Remote Display (Short Base) 5.8" 14.7 cm 0.00 Minimum 5.5" (14.0 cm) Maximum 11.75" (29.8 cm) lb 3.0" 7.6 cm " 95 m 0.4 c 2. 3.375" 0.953 cm 5" 1. cm 8 3. 4.5" 31.6 cm 6. Cut the stalk to fit your installation (if required). 7. Route the cable through the base/stalk so that you can plug the connector into the display head. 8. Remove the rubber band from the connector and attach the connector to the display head. 9. Slip the display head onto the stalk/base. 10.
Remote Scale Display Placement/Installation 11. Install mounting screws or bolts to complete the installation of the Remote Scale Display. Take care not to pinch or pierce the interface cable while securing the Remote Scale Display to the checkstand. Figure 2-15. Remote Scale Display Components Mounting Example 11.5" (29cm) 36" (91cm) Cable Connector 48 - 60" (122 - 152cm) Cable end after rubberband is removed.
Figure 2-16. Remote Scale Short Base Display Mounting Template 4 1/2" (11.4 cm) 1 1/2" (3.8 cm) 3 3/8" (8.57 cm) 3/4" (1.9 cm) FRONT Changing Weighing Modes Your scanner/scale has been programmed for weighing in either pounds or kilograms depending upon the initial operating environment that was specified when you ordered your scanner/scale. If you need to change from pounds to kilograms or vice-versa, call technical support.
Set-Up & Installation Set-Up & Installation These setup and installation procedures assume that you have already prepared your checkstand to receive the scanner or scanner/scale. If you have not already made the counter cutout and routed power and interface cables, do so now as described in the previous instructions.
Swapping Position: EAS Single-Antenna ONLY The EAS Antenna must be located in the position needed for your installation. Reference Figure 2-18 and. Locate it as described below: 1. Remove the platter (see Figure 2-22). 2. If the unit is a model containing a scale, and the scale assembly is determined to be in the position the EAS Single-Antenna should be with regard to product flow, proceed to the next step. Otherwise, skip to step 7. 3.
Set-Up & Installation 4. Disconnect the Load Cell harness. 5. Move the Load Cell/Spider Assembly into position on the opposite side of the scanner cavity and re-install the original screws. Torque the screws evenly to 50 in-lb. Figure 2-19. Locating the EAS Single-Antenna (Left-to-Right) Product Flow EAS Antenna Load Cell/Spider Assembly Load Cell Harness (bend for left-hand scale installation) 6. Route the Load Cell harness, re-bending it as indicated on the harness, and reconnect. 7.
Set-up 1. Place the scanner on the checkstand next to the counter cutout. 2. Make all connections to peripheral devices, such as the Remote Scale Display (see Figure 2-15) and EAS Controller Box (see Figure 2-20). Power on the EAS Controller Box. Figure 2-20. EAS Controller Box Connections To EAS Antenna To Power ON/OFF Switch To Scanner 3. Route the cables up through the cutout and connect the scanner and scale interface cable(s), EAS cable and Remote Scale Display cable (optional) to the scanner.
Set-Up & Installation Figure 2-21. Connecting Cables to the Scanner/Scale 0.00 POS Terminal POS TERMINAL Remote Display Aux.
Installation 1. Make sure that all cables are firmly attached (except that the AC/ DC power supply should not be connected to the AC outlet yet). Reference Figure 2-5, Figure 2-20, and Figure 2-21. 2. Remove the All Weighs™ Platter to gain access to the lift handles. Grasp the platter as shown in Figure 2-22 and gently lift it from the scanner. If the top edge of the platter is blocked, you may find it easier to grasp the platter vertical bezel as shown in Figure 2-22b. Figure 2-22.
Set-Up & Installation 3. Hook the fingers of both hands into the lift handles. The first is located along the inside of the front scanner wall, and the second is behind the scanner hood, as shown in Figure 2-23. DO NOT attempt to lift the unit using the EAS Antenna, plastic edges, scale frame, or any features other than the lift handles. CAUTION 4. Lower the unit into the counter opening, ensuring that none of the cables are pinched, pierced or crimped. 5.
Figure 2-23.
System Power-Up Recap System Power-Up Recap The System Power-Up procedure may vary depending upon the requirements of your POS system. It is generally a good practice to power-down (switch off ) all equipment prior to connecting cables. Check with your System Supervisor and/or refer to your POS terminal manual for proper power-down and power-up procedures and interface requirements when connecting any peripheral device.
6. Power-up the scanner or scanner/scale by connecting the power cord to an AC power outlet. Wait for the unit to complete the Self test routine (10 seconds maximum). Successful scanner power-up is signified by any or all of the following: - Facet wheel shows movement - Lasers turn on - Status LED(s) turn on - Speaker sounds tone(s) - Remote display shows message - A single red dot is visible on the 7-segment display 7. Power-up the POS terminal.
Chapter 3 Operation and Maintenance The information contained in this chapter describes how to operate and maintain the scanner, scale and EAS system. Topics include “how to’s” on scanning, EAS tag deactivation, weighing, re-zeroing the scale, removing the top cover and cleaning the upper and lower windows. Scanning Items To scan items using the scanner, slide or push them through the scan zone as shown in Figure 3-1.
Figure 3-1. Scan Zone Vertical Window Scan Zone Note that eyes... Horizontal Window Scan Zone ...indicate what the scanner "sees." Top Down Scan Zone Checker Side Scan Zone Proper Scanning Technique The scanner was designed to provide the ultimate in ergonomic enhancements for Point-Of-Sale (POS) scanning. To take advantage of these advancements: Practice the techniques below to improve scanning efficiency: 3-2 • Move the product across the horizontal window (See Figure 3-1).
Deactivating Security Labels Sensormatic® Ultra-Max®, Ultra-Strip® II and III EAS (Electronic Article Surveillance) tags can be detected and deactivated by the system. This is accomplished by means of a ScanMax deactivation antenna mounted under the scanner platter (single-antenna models) or both behind the vertical window and under the scanner platter (dual-antenna models). EAS tags should be brought within five inches of the antenna(s) to be deactivated.
EAS Deactivation Indicators The scanner can be programmed to beep in acknowledgement of deactivation or upon deactivation failure. Additionally, the tri-color indicator (the bottom-most LED) displays deactivation status. (For more information about Beeper and LED indications, see the LED/Beeper Indications & Controls chapter of this manual. Also reference the programming chapter for their configurable features.) By general default, LED indications are: • Green means the system is ready (standing by).
Proper Weighing Technique 1. The L-shaped All-Weighs™ platter allows you to place items anywhere on its surface, including leaning against its vertical section, to be weighed accurately. The raised “Produce Rail” also provides a convenient way to ensure items do not rest on the counter or other non-weighing surfaces. (Reference Figure 3-2.) It is important that items rest entirely on the platter for their full weight to be accurately recorded. NOTE Figure 3-2.
Operational Controls The function of scanner and scale controls and indicators is listed in Appendix A, LED/Beeper Indications & Controls. Turn to that appendix for full details. Operational Modes The scanner or scanner/scale features a number of modes that are important to both the user and the system support personnel. These modes can be combined into three groups: pre-operational, operational, and additional functions.
Operational Modes Error Reporting If a fatal error is detected during Selftest or operation, the unit will not advance to Normal Operation Mode. Selftest diagnostics will cause the unit to sound a long, low tone and/or display an error message on the 7segment display indicating where the failure occurred. These messages are coded to assist the repair technician in identifying the failed component. If the error is with the EAS deactivation system, the bottom-most LED will flash red.
• When the scanner or scanner/scale completes its Selftest successfully, it emits a tone (when configured to do so) and enters Operating Mode. Operating Mode Operating Mode includes Normal Operation (scanning, EAS deactivation and weighing) and Sleep Mode. These two modes are most commonly observed by the user/operator. Normal Operation This condition is indicated by the scanner green LED and the EAS deactivation LED both being on dim and steady.
Additional Functions Sleep Mode After the scanner has been left idle for a preset period of time, the laser and/or motor automatically turns off (goes to sleep). This state is called Sleep Mode, and is indicated by a “slow” blink of the green light (blinking at a 2-second rate). To wake up the unit, press anywhere on the weigh platter (scanner/scale models only), press the Volume Selection switch or wave your hand in front of the vertical window.
Pressing and holding the Volume/Tone Push Button for approximately eight seconds initiates a reset, which is sounded by a rapid number of beeps. If the motor had been spinning, the lamps will blink while the motor spins down. At that point, the motor will spin back up and the scanner will continue to run the Selftest diagnostics. For more information, see the topic, Power-Up/Selftest & Pre-Operation earlier in this chapter. Scale Adjustments The scale allows two user adjustments: zeroing and calibration.
Additional Functions Calibrating the Scale The second adjustment, calibration, defines and sets a standard reference weight range against which all product weights are compared. If your scale is set for weighing in pounds, this range is 0 - 30 pounds, and, if your scale is set for weighing in kilograms, the range is 0 - 15 kilograms.
Operational Maintenance The scanner or scanner/scale will provide dependable service for many years. The following maintenance procedures will keep your scanner or scanner/scale operating at peak performance. Cleaning the Weigh Platter and Scan Windows. Clean the exterior surfaces of the horizontal and vertical scan windows at least twice daily with a nonabrasive, mild, water-based glass cleaner and paper towels or lint-free cleaning tissues.
Operational Maintenance Vertical Scan Window Replacement The Vertical Scan Window enclosed in the All Weighs™ Platter is a replaceable part. Follow these instructions to remove and replace the window: To remove the Vertical Scan Window: 1. Grasp the platter as shown in Figure 3-3 and gently lift it from the scanner. Figure 3-3. Platter Removal a OR b Obstruction Vertical Bezel 2.
3. The vertical scan window is held in place by two tabs each on its top and bottom edges. To remove it, carefully push out on the top as shown in Figure 3-4 and lift it out. Carefully dispose of any damaged glass. Figure 3-4. Vertical Scan Window Removal/Replacement Vertical Scan Window 4. Fully seat the new vertical scan window into the window channel within its bottom retention tabs.
Operational Maintenance Horizontal Scan Window Replacement (WRG) Wear Resistant Glass (WRG) horizontal scan windows are replaceable and can be removed and replaced following the instructions below. Sapphire glass does not require replacement, so it is permanently fastened in place. Do not attempt to remove Sapphire glass from the platter. NOTE 1. Remove the All Weighs™ Platter from the scanner as shown in Figure 3-3. 2.
Figure 3-5.
Chapter 4 Problem Isolation In the event of a suspected functional problem, use the troubleshooting references provided in this chapter. This useful information will help you to identify and resolve the cause of the problem. The scanner/scale has a number of features that indicate when a scanner, EAS deactivation system, or scale problem occurs.
Operational Tests These are the tests that run continually during Normal Operation and Sleep Mode. Firmware checks all subsystems, accessory connections and the POS interface to verify everything is operating normally. If a problem is detected at any time, a long, low tone is sounded, an error code is shown on the 7-segment display, and operation may be halted. If you press the Volume/Tone Push Button at that time, a series of tones will be sounded that matches the error code displayed.
Error Codes Error Codes If an error is detected, the scanner will sound a long low tone (for one second) and alternately flash its LEDs, indicating a failure. Following the long low tone, an error code will appear on the 7-segment display (refer to Figure 4-1). Pressing the Volume/Tone Push button will cause the scanner to sound a series of beeps corresponding to that error code. The table on the following page describes what these codes mean and what action should be taken for each.
Error Code Probable Cause Corrective Action Configuration No POS interface has been selected (Null interface). See the topic, Interface Type, in Chapter 6 to select the required interface using programming bar codes. 1 Configuration Error See Chapter 6, Programming, for details about configuring the scanner using programming bar codes. 2 Interface Board Unplug unit and call technical support personnel. 3 Motor Unplug unit and call technical support personnel.
Scale Error Reporting Figure 4-1. 7-Segment LED Display 7-Segment Display Scale Error Reporting Scale diagnostics uses the Remote Scale Display and the Zero Status lamp to communicate specific scale failures. The following chart shows the Remote Display messages, the Scale Status lamp indication, the problem that the scale is experiencing and what action should be taken. When troubleshooting, always remember to check all cable connections first before proceeding with other problem isolation steps.
Remote Display Scale Status Lamp Problem Description Action Required E__3 Flash, pause, 3 blinks, long pause, repeat sequence. Scale communication lost. Internal scanner/scale problem. Call technical support personnel; report error. E__4 Flash, pause, 4 blinks, long pause, repeat sequence. Scale module failure. Call technical support personnel; report error. E__5 Flash, pause, 5 blinks, long pause, repeat sequence. Internal software fault. Call technical support personnel; report error.
Flowcharts Figure 4-2. Problem Isolation: Start For units using an AC/DC adapter, verify that... 1. AC power cord is connected to a functional AC outlet. 2. IEC connectors are firmly connected. 3. DC power cord is firmly connected to scanner. If your unit is a model which receives Power Off the Terminal POT), verify that the I/F cable is securely connected at both ends.
Figure 4-3. Problem Isolation: Selftest SELFTEST START Does the 7-segment display show 0 ? Does the 7-segment display show 1. ? NO Section 6 to enable the default configuration file. Restart the unit. NO YES No interface selected (Null Interface). Select an interface. Go to EAS System flowchart Does the 7-segment display show 9. ? Scan the Factory YES Defaults bar code in NO Does the 7-segment display show 2. or 3. ? NO YES Does the 7-segment display show 4. or 5.
Flowcharts Figure 4-4. Problem Isolation: Poor/No Reading Have you verified that all scan windows are clean and scratch-free? POOR/NO READING START Enter Scanner Diagnostic Mode by holding the Volume/Tone Push Button for 4 seconds (until first 3, and then 6 rapid tones are sounded) then release. Scan a known-good bar code. A good read is signified by one flash of the Green LED and a single beep1.
Figure 4-5. Problem Isolation: No Transmit to POS NO TRANSMIT TO POS START Check the interface (I/F) cable connections. If possible, retest the system using a knowngood I/F cable. Does the scanner pass the data to the POS ? YES NO Verify programmable parameters using the information and programming bar codes provided in Section 6. Check interface and I/F options, inactive symbologies and other configurable features.
Flowcharts Figure 4-6. Problem Isolation: Scale If this is a new installation, make sure any foam packing pieces have been removed from the scale cavity before proceeding. Lift off the platter to verify, then set the platter back into position. SCALE START View the Remote Display and/or the Yellow scale status LED for the scale error code. Reference the topic, Scale Error Reporting in Section 4 for more information. YES DONE YES -0shown on YES - Check for debris under platter.
Figure 4-7. Problem Isolation: Remote Display REMOTE DISPLAY START Is the unit configured for a Remote Display ? NO Scanner-scale models that include a Remote Display when shipped from the factory, are configured for use with the display. If you're unsure of the settings for your unit, contact Tech Support. Use the programming bar codes in Section 6 to enable operation using a Remote Display.
Flowcharts Figure 4-8. Problem Isolation: EAS System Before proceeding, verify the EAS Antenna(s) and EAS Control Box have been correctly installed (ref. Chapter 2). Ensure operator has been trained in proper EAS system use (ref. Chapter 3). NO EAS DEACTIVATION START Check all EAS cable connections. Verify programmable parameters using the information and programming bar codes provided in Section 6. Check EAS options, and other configurable features.
NOTES 4-14 Magellan® 9500
Chapter 5 Calibration A number of situations require the scale to be calibrated. They are: • at initial installation of the scanner/scale • if the scale cannot be re-zeroed • if you change the weight measure from pounds to kilograms or viceversa • if diagnostics indicate a calibration error • the weigh module has been replaced Follow the procedures on the following pages to ensure that the scanner/ scale will meet Weights and Measurement requirements.
Description of Calibration Sequence The Calibration Sequence sets the scale to an accurate reference point for weighing. This process involves the use of a Field Standard Weight Set (31.5-pounds) for calibration in pounds, (18.5-kilograms) for Metric. Once calibration has been successfully completed, the scanner/scale uses the certified weight as a reference for subsequent weighing activities. These verification procedures follow the U.S.
Motion Test Motion Test This test verifies that the scale will not ‘zero’ when the weighing surface of the scanner/scale is in motion. 1. Verify that the Yellow LED1 is on and the Remote Display reads 0.00 pounds or 0.000 kilograms. 2. Press lightly on the weigh platter of the scanner/scale with one hand and at the same time press and release the Zero Push Button on the operator’s panel. The Yellow LED should turn Off and the Remote Display should not display 0.00 pounds or 0.000 kilograms. 3.
Preparing the Scanner/Scale for Calibration 1. Assure that the scanner/scale is stable, secure and properly installed. (Refer to Chapter 2, Site Preparation and Installation for instructions on the proper installation of the scanner/scale). 2. Power-up the scanner/scale. 3. Allow the unit to reach temperature equilibrium for at least one hour. If the scanner/scale is already at room temperature, allow at least 15 minutes for acclimatization. 4.
Calibrating the Scale (Pounds & Kilograms) Figure 5-1. Calibration Access Cover Calibration Cover Calibration Switch 4. Press and release the Calibration Switch to place the scanner/scale in Calibration Mode. The scanner/scale will sound a tone indicating it is in Calibration Mode. If the motor was spinning when you initiated Calibration Mode, the motor will stop and the Yellow LED will begin flashing indicating the scale is in Calibration Mode. The display will show the message “ESCL” (empty scale). 5.
8. The Yellow LED will extinguish for approximately 10 seconds and the Remote Display will alternately display and until the scale is ready to proceed. 9. If the calibration was successful, the speaker sounds a single tone, the Scale Status LED begins blinking again, and “End-” appears in the Remote Display. 10.
Calibration Verification (U.S. Pounds) Calibration Verification (U.S. Pounds) Once you have completed the calibration sequence, you may be required to perform these step-by-step verification procedures. These procedures follow the National Institute of Standards and Technology Handbook-44 guidelines for grocery scale installations. You may be required by state or local law to have these procedures performed by a certified technician or verified by a proper official.
Shift Test The Shift Test checks to ensure that items placed anywhere on the weighing surface of the scanner/scale are weighed properly. Refer to Figure 5-2 when performing this test. 1. Place and remove in succession, a fifteen-pound load on the center of each of the four quadrants (A, B, C, and D in Figure 5-2) of the scanner/scale’s weigh platter. Verify that a reading of between 14.99 and 15.01 lb registers under load and that the display returns to 0.00 between each load. 2.
Calibration Verification (U.S. Pounds) Increasing- Load Test (Phase 2) After completing the Shift Test, you must complete the Increasing Load Test using 20.0, 25.0 and 30.0 pounds of weight. NOTE The upper limit of the scale is configurable according to POS interface type and may not necessarily be set at 30 pounds, which is the standard setting. For this test, continue to place weights in five pound increments only up to the upper weight limit set for your scale. 1.
Decreasing-Load Test This test ensures that the scanner/scale responds properly when a heavy object is followed by a significantly smaller object. 1. Place a 30.0-pound load on the scale and verify that the display shows between 29.99 and 30.01 pounds. If the upper weight limit for your scale is not set at 30 pounds, begin by placing weight equaling your upper limit setting. NOTE 2. Remove weights to leave 20 pounds on the scale. Check that the display shows between 19.99 and 20.01. 3. Remove another 15.
Calibration Verification (Kilograms) Calibration Verification (Kilograms) Once you have completed the calibration sequence, you may be required to perform these step-by-step verification procedures. These procedures follow the National Institute of Standards and Technology Handbook-44 guidelines for grocery scale installations. You may be required by state or local law to have these procedures performed by a certified technician or verified by a proper official.
8. Place an additional 200 grams on the center of the weighing surface and check that the display reads 1.000 kg. 9. Increase the weight on the scale to 7.50 kg on the center of the weighing surface and check that the display reads between 7.495 and 7.505 kg. 10. Remove the weights and verify that the display reads 0.000 kg. You have completed the Increasing-Load Test (Phase 1).
Calibration Verification (Kilograms) Figure 5-3. European Shift Test (Metric) A B CENTER A C B TER CEN C D D Increasing- Load Test (Phase 2) After completing the Shift Test, you must complete the Increasing Load Test using 10.00, 12.50 and 15 kilograms of weight. NOTE The upper limit of the scale is configurable according to POS interface type and may not necessarily be set at 15 kilograms, which is the standard setting. For this test, continue to place weights in 2.
Blanking Test This test ensures that the scanner/scale will indicate its weighing capability has been exceeded if a weight greater than 0.82 over its maximum upper weight limit is placed upon the unit. 1. Place weights that total the upper limit plus 0.82 kilograms on the weigh platter. For example: If the upper limit is set at 15 kilograms, place weights equaling 15.82 kilograms. 2. Verify that the display shows a dash and three hyphens ( _ - - -). This is the overweight indication.
Calibration Verification (Kilograms) Decreasing-Load Test This test ensures that the scanner/scale responds properly when a heavy object is followed by a significantly smaller object. 1. Place weights that total 15.8 kilograms. If the upper weight limit for your scale is not set at 15 kilograms, begin by placing weight equaling your upper limit setting plus 0.8 kilograms. NOTE 2. Remove weights to leave 10 kilograms on the scale and verify that the display shows between 9.990 and 10.010 kilograms. 3.
NOTES 5-16 Magellan® 9500
Chapter 6 Programming Introduction to Label Programming The programming bar code labels contained in this manual will allow you to customize and configure features and settings for your scanner (scanner/scale). To ensure full compatibility and proper function, use only the programming bar codes in this manual and other product-specific publications to program scanner features.
Integrating the Scanner With Your Host System Your scanner MUST be equipped with the correct hardware (interface board, cable, etc.) to properly communicate with your host system. Contact your dealer for information if you have questions about your scanner’s hardware compatibility. You may also want to contact the dealer or your system administrator if you have no record of how your scanner was pre-programmed at the factory.
Integrating the Scanner With Your Host Sys- • CAUTION Interface Related Features — are the mandatory settings necessary to allow communication with your host terminal. Examples of these settings are: RS-232 baud rate and parity. It is possible, via programming bar codes, to change the interface type (for example: from RS-232 to IBM Port 17).
Programming Overview The scanner’s programmable feature settings can be modified to accommodate your system’s unique requirements. These settings can be communicated to the scanner in one of three ways: 1. Commands can be sent directly from the host. A limited set of host commands are available. Refer to Appendix D for more details or contact Tech Support. 2. The easiest, most comprehensive way to program the scanner is to use the Configurator Express™ On-Screen Programmining Kit.
Programming Overview What Is Programming Mode? Programming Mode is a state in which the scanner must be placed in order to accept commands via programming bar code labels. When programming using the bar code labels in this manual, the scanner is typically placed in Programming Mode by scanning the SWITCH label. While in the Programming Mode, the scanner only recognizes ONLY the special programming bar codes contained in this programming guide.
Programming Session A typical programming session is conducted as follows: 1. Scan the SWITCH bar code to place the scanner in Programming Mode. Depending upon its current programming, the scanner may emit a beep or beeps, indicating it has read the bar code and the scanner (top) green LED will flash on and off slowly while the scanner remains in Programming Mode. Normal scanning functions are disabled. 2. Scan the programming bar code(s) that is (are) specially encoded to make the desired changes.
Programming Overview NOTE It is recommended that programming sessions be limited to one feature at a time. Should you make a mistake in the programming sequence, it can be difficult to discover where an error has been made if several features are programmed at once. Additionally, it can be confusing to determine which features may or may not have been successfully set following such a session. 3. Scan the SWITCH bar code to save any new settings and exit Programming Mode.
Programming Sequence To modify a scanner feature (item), the programming bar codes contained in this manual must be scanned in a given sequence depending upon the feature being programmed (as shown in Table 6-1). There are three possible programming sequences: NOTE If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session.
Programming Overview Table 6-1. Programming Sequence SET A ITEM TAG ITEM VALUE END/RESET 1 2 3 SWITCH ENABLE NEW FEATURE SWITCH 1 2 345 6 0 B SWITCH C ENABLE NEW FEATURE USING THE FOLLOWING SETTINGS...
LED and Beeper Indicators The scanner provides a set of indicators that verify/announce the various scanner functions. If You Make a Mistake... If, during a programming session, you find that you are unsure of the scanner’s settings or wish to reset the scanner’s configuration, use the Return to Factory Settings label below to return the scanner’s configuration to the factory settings. Scanning this label will also reset any changes made during previous programming sessions.
If You Make a Mistake... Test Mode Use this feature to place the scanner into a testing, or “demo” mode. This special mode disables the scanner interface, meaning that bar code data is not sent out to the host via the scanner interface. This allows the bar code to be scanned continuously without requiring a response from the POS terminal. To return the scanner to normal function, scan the TEST MODE = DISABLE bar code below.
General Scanner and Scale Features Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession). To set the Double Read Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
General Scanner and Scale Features Double Read Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Laser Timeout The laser timeout feature sets the time for switching the visible laser diodes (VLDs) off if the scanner is idle. Using this feature can prolong the life of the VLDs. To set the Laser Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner and Scale Features Laser Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Motor Timeout The Motor Timeout feature sets the time for automatically switching the motor off when the scanner is not in use. Laser safety requires that the laser switch off before the motor. If you set the motor timeout shorter than the laser timeout, the motor and the laser will both shut off when the motor timeout expires. NOTE To set the Motor Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
General Scanner and Scale Features Motor Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Motor Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner and Scale Features Green LED Idle State This feature specifies the state of the green scanner LED when the scanner is idle and ready to read a label. Options are: • Off • On dim To set the LED Idle State: 1. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 2. Complete the programming sequence by scanning the SWITCH bar code.
Scanner Button Options Configure the scanner volume button to one of the following modes of operation: • Enable all functions: Volume, tone, diagnostics and reset. • Enable only volume, tone and reset. • Enable reset only. • Disable all button functions To set the desired Scanner Button Option: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
General Scanner and Scale Features Scanner Button Options — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Power-up Beep Control Specifies the type of audible indication that is made when entering scanner-active mode on power-up. Choices are: • No beep • One beep • Three beeps To set the Power-up Beep: 1. Scan the SWITCH bar code. 2. Scan your selection from the three bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner and Scale Features Power-up Beep Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Good Read Beep Control This feature enables/disables scanner beep upon successfully decoding of a label. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the two bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner and Scale Features Good Read Beep Frequency Adjusts the scanner’s good read beep to sound at low, medium, or high frequency (controls the beeper’s pitch/tone). • Low = 660 Hz • Medium = 860 Hz • High = 1050 Hz To set the Good Read Beep Frequency: 1. Scan the SWITCH bar code. 2. Scan your selection from the three bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Good Read Beep Frequency — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner and Scale Features Good Read Beep Length Specifies the duration of a good read beep. To set the good read beep length: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GOOD READ BEEP LENGTH. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired good read beep length setting.
Good Read Beep Volume Selects the beeper volume upon a good read beep. There are five selectable volumes, with each volume increment adding approximately five decibels to the previous level: • 0 = Lowest Volume • 1 = Medium-Low Volume • 2 = Medium Volume • 3 = Medium-High Volume • 4 =Highest Volume To set the Good Read Beep Volume: 1. Scan the SWITCH bar code. 2. Scan your selected volume bar code from this or the following pages.
General Scanner and Scale Features Good Read Beep Volume — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Good Read Beep Volume — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner and Scale Features Good Read When to Indicate This feature specifies when the scanner will provide indication (beep and/ or flash its green LED) upon successfully reading a bar code. • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read = Indicate after CTS goes inactive, then active The “Indicate after CTS goes inactive...” mode applies to RS-232 STD and RS232 WN interfaces only.
Good Read When to Indicate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner and Scale Features Scale Enable Use this feature to enable or disable scale operation. Recalibration/recertification may be required when adding scale functionality. Consult your local Weights and Measures authority. NOTE If this feature is enabled the scanner will expect that it is to function as a scanner-scale, and will indicate an error if it is not a scale-equipped unit. See Error Codes in Chapter 4 for more information. To set this feature: 1. Scan the SWITCH bar code. 2.
Scale Country Mode When a weight is presented, the scanner/scale will apply the country-specific weighing rules specified via this feature. Scale Country Mode applies only when a scale is enabled. RS-232 SASI scale interface supports only U.S.A. mode. NOTE SCALE COUNTRY MODE = U.S.A. SCALE COUNTRY MODE = U.K.
General Scanner and Scale Features Scale Country Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale Enforced Zero Return This feature enables/disables the enforced zero return of the scale.
General Scanner and Scale Features Scale Enforced Zero Return — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale Interface Type Use this feature to select the scale interface type. Choices are: • No Scale Interface • RS-232 — SASI • RS-232 — ICL To set the Scale Interface Type: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner and Scale Features Scale Interface Type — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale Motion Level Filter In environments where checkstands generate excessive vibration, the scale can be set to filter a certain amount of the motion with regard to its operation. This filter is generally used only in applications where scale error E_1 (too much motion at power-up) has occurred. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
General Scanner and Scale Features Scale Motion Level Filter — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale LED Enable This feature enables/disables Scale LED (Yellow LED) operation. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the two bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner and Scale Features Remote Display — Enable/Disable The scanner-scale can be configured to operate with or without a Remote Display. Recalibration/recertification may be required when adding a Remote Display. Consult your local Weights and Measures authority. NOTE If this feature is enabled the scanner-scale will expect that it is connected to a Remote Display, and will indicate an error if one is not. See Error Codes in Chapter 4 for more information.
Aux Port Mode Selects the usage for the scanner’s optional auxilliary port. The choices listed below are mutually exclusive (only one option can be active at a time). • Disabled — Port is inactive • External Handheld Input — Supports Datalogic® handheld scanners (QuickScan 1000, QuickScan 6000, PowerScan) as well as other models such as the Symbol® HotShot. Call your dealer for more information about supported devices. Cable pinout information for the Aux Port is provided in Appendix B of this manual.
General Scanner and Scale Features Aux Port Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Laser Failure Mode This configuration item selects whether the scanner should continue operating if only one laser is functional. (The scanner has two lasers: One for the horizontal window, and one for the vertical window.) Options for this feature are: • Single Laser Failure OK — The scanner can still operate even if one laser is no longer functional. In this mode the scanner will read only from the window associated with the operational laser.
General Scanner and Scale Features Productivity Index Reporting (PIR)/Cashier Training (CT) When PIR/CT is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read. CT allows the scanner to provide feedback to the cashier on how to scan in a more ergonomic fashion. This value-added feature is a factory-programmed option.
EAS Features EAS Mode This controls the mode of operation for interfacing with the Sensormatic® ScanMax ProTM EAS device. Choices are: • Disabled = EAS deactivation turned off. • Coupled Mode = EAS tag is deactivated only upon successful scanning of an item’s barcode or via manual push button. • Decoupled Mode = EAS deactivation is performed independently of barcode scanning.
EAS Features EAS Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAS Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAS Features EAS Beep Duration Sets the duration of the EAS successful deactivation beep, specified in 10ms increments. The beep only occurs if EAS mode is not disabled. To set the EAS Beep Duration: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAS BEEP DURATION below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
EAS Retry Count This feature sets the number of times the deactivation sequence (defined by the feature, “EAS Deactivation Duration — Retry ”) is restarted after a failed deactivation attempt. To set the EAS Retry Count: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAS RETRY COUNT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
EAS Features Manual EAS Deactivation Push Button This feature is for use in Coupled Mode1. When it is enabled, EAS deactivation can be manually initiated by placing the item with the EAS tag downstream2 of the horizontal scan window and pushing the Manual EAS Deactivation Push Button. The scanner emits a clicking sound while in deactivation state. NOTE Duration of deactivation state is determined by the feature, EAS Deactivation Duration — Manual.
Manual EAS Deactivation Push Button — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAS Features Manual EAS Deactivation Push Button — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAS Deactivation Duration — Coupled Specifies the amount of time EAS deactivation is operative once the function has been initiated following a bar code read. This setting pertains only to units configured for EAS Coupled Mode. Reference the EAS Mode description for more information about Coupled and Decoupled EAS operation. NOTE To set the EAS Deactivation Duration — Coupled: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAS DEACTIVATION DURATION — COUPLED below.
EAS Features EAS Deactivation Duration — Retry Specifies the amount of time EAS deactivation is operative once the function has been initiated following EAS tag detection (prior to bar code read).. This setting pertains only to units configured for EAS Coupled Mode. Reference the “EAS Mode ” description for more information about Coupled and Decoupled EAS operation. Also reference “EAS Retry Count .” NOTE To set the EAS Deactivation Duration — Retry: 1. Scan the SWITCH bar code. 2.
EAS Deactivation Duration — Manual Specifies the amount of time EAS deactivation is operative upon pushing the Manual EAS Deactivation Push Button. This setting pertains only to units configured for EAS Coupled Mode. Reference the “EAS Mode ” description for more information about Coupled and Decoupled EAS operation. Also reference “EAS Retry Count .” NOTE To set the EAS Deactivation Duration — Manual: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAS DEACTIVATION DURATION — MANUAL below.
Interface Related Features Interface Related Features Interface Type Specifies the current scanner interface. Selections are: INTERFACE TYPE INTERFACE IDENTIFICATION NUMBERa RS-232 Standard 05 RS-232 Wincor-Nixdorf 12 RS-232 Single Cable 20 IBM USB 45 IBM Port 17 04 NOT USER-SELECTABLE Null Interface Indicated by 7-segment FRU display flashing 0 at start-up a.
Interface Type — continued To select the desired interface: CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features RS-232 Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
RS-232 Wincor-Nixdorf Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features RS-232 Single Cable Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
IBM Port 17 Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED. Single cable installations require connection at the POS Terminal (host) port.
Interface Related Features IBM USB Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Maximum Host-Transmitted Message Length Specifies the maximum number of data characters allowed in messages transmitted to the host. To set the Maximum Host-Transmitted Message Length: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MAXIMUM HOST-TRANSMITTED MESSAGE LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Interface Related Features Number of Host Transmission Buffers Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted.
Global Prefix This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the prefix that is added to beginning of label transmission. To specify the Global Prefix Character(s): 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GLOBAL PREFIX below. You’ll need to cover any unused bar codes to ensure the scanner reads only the bar code you intend to scan. 3.
Interface Related Features Global Prefix — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Global Suffix This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the suffix that is added to end of a label transmission. Three standard options are available below. Contact your dealer for other alternate settings for this feature. • No Global Suffix • CR — Carriage Return • CR LF — Carriage Return, Line Feed To set the Global Suffix: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. 3.
Interface Related Features Global Suffix — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM Features IBM Interface Options IBM interfaces offer specific control over interaction with certain devices. The IBM USB interface provides its own set of options. Refer to the feature, IBM USB Interface Options, in this chapter. NOTE Options for this feature are as follows: • FULL host interface support — Accepts scanner and scale configuration host commands. • Ignore host interface configuration of scanner and scale — Ignores all scanner and scale configuration host commands.
IBM Features IBM Scale Address This feature applies to IBM Port 17 ONLY. NOTE Specifies IBM scale address for IBM Port 17. The following three addresses are available: • 6A • 6B • 6E To set the IBM Scale Address: 1. Scan the SWITCH bar code. 2. Scan the bar code below or from the following page that represents the desired scale address designation. 3. Complete the programming sequence by scanning the SWITCH bar code.
IBM Scale Address — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM Features IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM Port 5B; Code 93 and Codabar for IBM Port 9B; Code 128, Code 93 and Codabar for IBM-USB. When enabled, this feature has no effect on IBM Port 17. NOTE To enable/disable the IBM Transmit Labels in Code 39 Format feature: 1.
IBM USB Interface Options The IBM-USB interface offers specific control over interaction with certain devices. Options for this feature are as follows: • FULL host interface support — Accepts scanner and scale configuration host commands. • Compatible with Magellan SL host interface support — Uses Magellan SL host interface support. • Ignore host interface configuration of scanner and scale — Ignores all scanner and scale configuration host commands. This feature applies only to the IBM USB interface.
IBM Features IBM USB Interface Options — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM USB Scanner Device Type The IBM-USB protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB POS, you may need to change this setting to enable all scanners to communicate. Options are: • Table Top Scanner • Handheld Scanner To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
RS-232 Features RS-232 Features RS-232 Baud Rate This feature selects the baud rate required for sending and receiving data. Single cable interfaces are limited to Baud Rate selections up to 19200. They cannot communicate at Baud Rates of 38400 and up. NOTE To specify the RS-232 Baud Rate: 1. Scan the SWITCH bar code. 2. Scan the desired baud rate from the bar codes below and on the immediately following pages.
RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Number of Data Bits Specifies number of data bits required for sending and receiving data. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired Data Bit setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Number of Stop Bits Specifies number of stop bits required for sending and receiving data. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired Stop Bit setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Parity Specifies parity required for sending and receiving data. Options for this setting are: • RS-232 PARITY = NONE • RS-232 PARITY = EVEN • RS-232 PARITY = ODD To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below or on the following pages representing the desired Parity setting. You’ll need to cover any unused bar codes, as well as facing pages to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Parity — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Hardware Control Enables/disables use of the RS-232 CTS signal for flow control and/or scan control. Options are: • Disable — The scanner transmits to the host regardless of any activity on the CTS line. • Enable CTS Flow Control — The CTS signal controls transmission of data to the host. • Enable CTS Scan Control — The CTS line must be active for scanner to read and transmit data.
RS-232 Hardware Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Intercharacter Delay Specifies delay between the end of one character and the beginning of the next in 10-millisecond increments. To set the RS-232 Intercharacter Delay: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 INTERCHARACTER DELAY. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Software Flow Control Enables/disables RS-232 Flow Control using XON/ XOFF characters. . This item will be ignored when the feature, RS-232 NAK Character, is enabled NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Host Echo When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary.
RS-232 Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host. • 0 - 100 = Time in 10-millisecond increments. To set the Host Echo Quiet Interval: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 HOST ECHO QUIET INTERVAL.
RS-232 Features RS-232 Ignore Host Commands When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active, transmit labels, and transmit scale information. For normal operation of the interface, disable this feature. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
RS-232 TTL Specifies whether RS-232 interface provides TTL levels on the output pins TxD and RTS. Choices are: • Normal RS-232 levels • TTL levels To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 TTL Invert Enables/disables inversion of TTL. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Beep on ASCII BEL Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex). • Disable • Enable To enable/disable this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Beep After Weigh Enables/disables the ability of the scanner to beep after weight data is transmitted to the host. Scale interfaces that support this item are: RS-232 ICL, RS-232 SASI, and RS-232 Single Cable. To enable/disable the Beep After Weigh feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Beep on Not on File Select for the host to beep (or not) when a not-on-file condition is detected by the host. This feature is also applicable to single cable RS-232.
RS-232 Features RS-232 ACK NAK Enable This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
RS-232 ACK NAK Enable — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 ACK Character This feature specifies which ASCII character will be used as an ACK character. NOTE DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits. To specify the RS-232 ACK Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 ACK CHARACTER below.
RS-232 NAK Character This feature specifies which ASCII character will be used as a NAK character. NOTE DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits. To specify the RS-232 NAK Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 NAK CHARACTER below.
RS-232 Features RS-232 Retry on ACK NAK Timeout This option specifies the action scanner performs on expiration of the RS232 ACK NAK Timeout Value. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 ACK NAK Timeout Value This item specifies the time the scanner will wait for an ACK character from the host following a label transmission. • 0 = Infinite timeout • 1 - 75 = Timeout in 200-millisecond increments To set the ACK NAK Timeout Value: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 ACK NAK TIMEOUT VALUE. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Features RS-232 ACK NAK Retry Count This feature sets the number of times for the scanner to retry a label transmission under a retry condition. To set the RS-232 ACK NAK Retry Count: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 ACK NAK RETRY COUNT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. • Ignore Errors (recommended setting) • Assume ACK (risk of lost label data) • Assume NAK (risk of duplicate label) To select the option for RS-232 ACK NAK Error Handling: 1. Scan the SWITCH bar code. 2.
RS-232 Features RS-232 ACK NAK Error Handling — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Label ID Control This feature specifies whether or not Label IDs are transmitted to the host and if so, whether to attach them as a prefix or suffix.
RS-232 Features RS-232 Label ID Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 Options The RS-232 Single Cable interface shares some configuration options with other RS-232 interfaces.
Single Cable RS-232 Options Single Cable RS-232 Scanner Only Protocol This sets the type of interface protocol that will be used in Single Cable RS-232. Options are: • Scanner/scale RS-232 protocol • Scanner only RS-232 protocol To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired option. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Single Cable RS-232 RTS CTS Selection Specifies how RTS and CTS are used to control the data flow. RTS is controlled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scanner looks at CTS, as the configuration values state, to determine when to send label data.
Single Cable RS-232 Options Single Cable RS-232 RTS CTS Selection — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 RTS CTS Selection — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 Options Single Cable RS-232 Use BCC Enables/disables the ability of the scanner to use BCC. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 Use ACK/NAK Enables/disables the ability of the scanner to use ACK/NAK. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 Options Single Cable RS-232 Use STX Enables/disables the ability of the scanner to use STX. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Set Single Cable RS-232 STX Character This feature selects the STX character. To specify the STX Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET SINGLE CABLE RS-232 STX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character.
Single Cable RS-232 Options Single Cable RS-232 Use ETX Enables/disables the ability of the scanner to use ETX. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Set Single Cable RS-232 ETX Character Allows selection of the ETX character. To specify the ETX Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET SINGLE CABLE RS-232 ETX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character.
Symbology Programming Symbology Programming If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session. (Selecting an interface type resets ALL other configuration items — including symbology programming — to the factory default for that interface type.) NOTE UPC-A Enable Enables/disables the ability of the scanner to decode UPC-A labels. To set this feature: 1. Scan the SWITCH bar code. 2.
UPC-A Number System Character Transmission Enables/disables transmission of a UPC-A number system character. This feature MUST be enabled for IBM interfaces for proper function. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
UPC-A Enable UPC-A Check Character Transmission Enables/disables transmission of a UPC-A check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Expand UPC-A to EAN-13 Enables/disables expansion of UPC-A labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Enable UPC/EAN AIM ID This feature enables/disables transmission of the UPC/EAN AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Label ID This feature specifies a UPC-A label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
UPC-A Enable UPC-A 2-Digit Supplemental Label ID This feature specifies a UPC-A 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 2-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-A 5-Digit Supplemental Label ID This feature specifies a UPC-A 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 5-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-A Enable UPC-A 128 Supplemental Label ID This feature specifies a UPC-A 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 128 SUPPLEMENTAL LABEL ID below.
UPC-E Enable Enables/disables the ability of the scanner to decode UPC-E labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Enable UPC-E Number System Character Transmission Enables/disables transmission of a UPC-E number system character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
UPC-E Check Character Transmission Enables/disables transmission of a UPC-E check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Enable Expand UPC-E to UPC-A Enables/disables expansion of UPC-E labels to UPC-A. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Expand UPC-E to EAN-13 Enables/disables expansion of UPC-E labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Enable UPC-E Label ID This feature specifies a UPC-E label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
UPC-E 2-Digit Supplemental Label ID This feature specifies a UPC-E 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 2-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-E Enable UPC-E 5-Digit Supplemental Label ID This feature specifies a UPC-E 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 5-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-E 128 Supplemental Label ID This feature specifies a UPC-E 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 128 SUPPLEMENTAL LABEL ID below.
EAN-13 Enable EAN-13 Enable Enables/disables the ability of the scanner to decode EAN/JAN-13 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 First Character Transmission Enables/disables transmission of EAN/JAN-13 first character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 Enable EAN-13 Check Character Transmission Enables/disables transmission of an EAN/JAN-13 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 ISBN Conversion Enable Enables/disables conversion of EAN/JAN-13 labels starting with 978 to Bookland ISBN labels. If any add-on information is present on the label prior to the conversion to ISBN, the add-on data will be discarded. Only the base label will be converted. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
EAN-13 Enable EAN 13 Label ID This feature specifies an EAN 13 label ID to be added to bar code data. To set this feature: The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN 13 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan.
EAN-13 2-Digit Supplemental Label ID This feature specifies an EAN-13 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 2-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-13 Enable EAN-13 5-Digit Supplemental Label ID This feature specifies an EAN-13 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 5-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-13 128 Supplemental Label ID This feature specifies an EAN-13 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 128 SUPPLEMENTAL LABEL ID = DISABLE below.
EAN-13 Enable Bookland AIM ID This feature enables/disables transmission of the Bookland AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Bookland Label ID This feature specifies a Bookland label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET BOOKLAND LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
EAN-8 Enable EAN-8 Enable Enables/disables the ability of the scanner to decode EAN/JAN-8 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Check Character Transmission Enables/disables transmission of an EAN/JAN-8 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Enable Expand EAN-8 to EAN-13 Enables/disables expansion of EAN/JAN-8 labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN 8 Label ID This feature specifies an EAN 8 label ID to be added to bar code data. To set this feature: The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN 8 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
EAN-8 Enable EAN-8 2-Digit Supplemental Label ID This feature specifies an EAN-8 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 2-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-8 5-Digit Supplemental Label ID This feature specifies an EAN-8 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 5-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-8 Enable EAN-8 128 Supplemental Label ID This feature specifies an EAN-8 128 Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 128 SUPPLEMENTAL LABEL ID below.
EAN-8 Decoding Levels Decoding levels allow the decoder to be set to perform at one of four selectable levels: • Very Conservative — Slower scan time, virtually eleminates misreads. The most secure setting. • Slightly More Aggressive — Faster scanning, more aggressive, yet minimizes misreads. • Moderately Aggressive — Even faster scanning, even more aggressive. • Very Aggressive — Fastest scan speed, most aggressive.
EAN-8 Enable EAN-8 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options Other UPC/EAN Options The following pages contain other selectable features for UPC/EAN symbologies: • UPC/EAN Reconstruction • Price Weight Check • Enable EAN Two Label • Addons • UPC-A and EAN-13 Decoding Levels Product Reference Guide 6-159
UPC/EAN Reconstruction Enables/disables the ability of the scanner to decode a class of UPC/EAN labels with voids. The label voids may be caused by printing defects or physical damage. This feature may be helpful in environments with instore printed labels. Enabling this feature increases the potential of misreads. CAUTION To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Other UPC/EAN Options Price Weight Check Enables/disables calculation and verification of price/weight check digits. Applies to all UPC-A and EAN/JAN-13 labels with eligible1 Number System/First Character digits. Options are: • Disable • 4-digit price/weight • 5-digit price/weight • 4-digit European price/weight • 5-digit European price/weight To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages.
Price Weight Check — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options Price Weight Check — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Enable EAN Two Label Enables/disables the ability of the scanner to decode EAN two-label pairs. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. Table 6-2 Contact Customer Support for details about advanced programming for this feature.
Other UPC/EAN Options Addons The scanner is capable of processing different types of addon codes, including: • 2-Digit Supplemental • 5-Digit Supplemental Options are provided on the following pages for your convenience: • Disable all addons — The scanner will not look for or read addons. • Optional 2-Digit and 5-Digit Supplemental — Bar codes can be read which include 2-Digit or 5-Digit Supplementals, however, it is not required that addons be included in bar codes.
Addons — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options UPC-A and EAN-13 Decoding Levels Decoding levels allow the decoder to be set to perform at one of four selectable levels: • Very Conservative — Slower scan time, virtually eleminates misreads. The most secure setting. • Slightly More Aggressive — Faster scanning, more aggressive, yet minimizes misreads. • Moderately Aggressive — Even faster scanning, even more aggressive. • Very Aggressive — Fastest scan speed, most aggressive.
UPC-A and EAN-13 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options UPC-A and EAN-13 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GTIN Enable Enables/Disables the ability to convert UPCE, UPCA, EAN8, and EAN13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN bar code. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
GTIN Enable GTIN Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN LABEL ID below.
GTIN 2-Digit Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 2-digit supplemental addon bar code labels are converted. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN 2-DIGIT SUPPLEMENTAL LABEL ID below.
GTIN Enable GTIN 5-Digit Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 5-digit supplemental addon bar code labels are converted. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN 5-DIGIT SUPPLEMENTAL LABEL ID below.
GTIN Code 128 Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and Code 128 supplemental addon bar code labels are converted The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN CODE 128 SUPPLEMENTAL LABEL ID below.
RSS-14 Enable RSS-14 Enable Enables/disables the ability of the scanner to decode RSS-14 labels. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RSS-14 Check Character Transmission Enables/disables transmission of the RSS-14 check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS-14 Enable RSS-14/EAN-128 Emulation Enables/disables the ability of RSS-14 to be transmitted as EAN-128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS-14 2D Component Enable When this feature is enabled, and the software reads an RSS-14 bar code that has a 2D component associated with it, the RSS-14 bar code will not be reported to the terminal. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS-14 Enable RSS-14 AIM ID This feature enables/disables transmission of the RSS-14 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS-14 Label ID This feature specifies an RSS-14 label ID to be added to bar code data. To set this feature: The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS-14 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
RSS Expanded Enable RSS Expanded Enable Enables/disables the ability of the scanner to decode RSS-Expanded labels. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
RSS Expanded EAN-128 Emulation Enables/disables EAN-128 emulation for RSS Expanded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS Expanded Enable RSS Expanded 2D Component Enable When this feature is enabled, and the software reads an RSS Expanded bar code that has a 2D component associated with it, the RSS Expanded bar code will not be reported to the terminal. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RSS Expanded AIM ID This feature enables/disables transmission of the RSS Expanded AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS Expanded Enable RSS Expanded Label ID This feature specifies an RSS Expanded label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED LABEL ID below.
RSS Expanded Length Control This feature specifies either variable-length or fixed-length decoding for RSS Expanded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RSS Expanded Enable RSS Expanded Maximum Label Length This feature specifies the maximum allowable length of an RSS Expanded label. Length in this case includes check and data characters. This applies when RSS Expanded Length Control is set to variable-length decoding. NOTE Maximum Label Length should be greater than or equal to Minimum Label Length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED MAXIMUM LABEL LENGTH below.
RSS Expanded Minimum Label Length This feature specifies the minimum allowable length of an RSS Expanded label. Length in this case includes check and data characters. This applies when RSS Expanded Length Control is set to variable-length decoding. NOTE Minimum Label Length should be less than or equal to Maximum Label Length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED MINIMUM LABEL LENGTH below.
RSS Expanded Enable RSS Expanded Fixed Length 1 This feature specifies RSS Expanded first fixed length. This applies when RSS Expanded Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RSS Expanded Fixed Length 2 This feature specifies RSS Expanded second fixed length. This applies when RSS Expanded Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RSS EXPANDED FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 39 Enable Code 39 Enable Enables/disables the ability of the scanner to decode Code 39 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Start Stop Character Transmission Enables/disables transmission of Code 39 start and stop characters. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 Check Character Calculation Enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in label is treated as a data character. If check calculation is disabled, the risk is increased that a misread can occur. NOTE In particular, if you are using variable length stitching, it is important to use check character calculation to prevent misreads. To set this feature: 1. Scan the SWITCH bar code. 2.
Code 39 Check Character Transmission Enables/disables transmission of optional Code 39 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 Full ASCII Enables/disables the ability of the scanner to translate to Code 39 full ASCII labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 AIM ID This feature enables/disables transmission of the Code 39 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 Label ID This feature specifies a Code 39 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 39 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 Maximum Label Length This feature specifies the maximum allowable length of a Code 39 label. Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 MAXIMUM LABEL LENGTH below.
Code 39 Minimum Label Length This feature specifies the minimum allowable length of a Code 39 label. Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variable-length decoding. NOTE Minumum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 MINIMUM LABEL LENGTH below.
Code 39 Enable Code 39 Fixed Length 1 This feature specifies Code 39 first fixed length. This applies when Code 39 Length Control is set to fixed-length decoding. NOTE The minimum decodable length is four when an optional check character is present. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 39 Fixed Length 2 This feature specifies Code 39 second fixed length. This applies when Code 39 Length Control is set to fixed-length decoding. If Fixed Length 2 is set to 00, then Fixed Length 1 will apply NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 39 Enable Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Pharmacode 39 Enable Enables/disables the ability of the scanner to decode Italian Pharmacode 39 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Pharmacode 39 Enable Pharmacode 39 Start Stop Character Transmission Enables/ disables transmission of start and stop characters for Pharmacode 39. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Pharmacode 39 Check Character Transmission Enables/disables transmission of Pharmacode 39 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Pharmacode 39 Enable Pharmacode 39 Label ID This feature specifies a Pharmacode 39 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET PHARMACODE 39 LABEL ID below.
Code 128 Enable Enables/disables1 the ability of the scanner to decode Code 128 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. CODE 128 = DISABLE CODE 128 = ENABLE 1.
Code 128 Enable Code 128 Transmit Function Characters Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4. Disabled is the recommended setting for all interfaces. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Convert Code 128 to Code 39 Enables/disables conversion of Code 128 labels to Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Enable Code 128 AIM ID This feature enables/disables transmission of the Code 128 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Label ID This feature specifies a Code 128 label ID to be added to bar code data.. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 128 Enable Code 128 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Maximum Label Length This feature specifies the maximum allowable length of a Code 128 label. Length in this case includes function characteres and data characters, but does not include function code change or check character. This feature applies when Code 128 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Code 128 Enable Code 128 Minimum Label Length This feature specifies the minimum allowable length of a Code 128 label. Length in this case includes function characteres and data characters, but does not include function code change or check character. This feature applies when Code 128 Length Control is set to variable-length decoding. NOTE Minumum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Code 128 Fixed Length 1 This feature specifies Code 128 first fixed length. This applies when Code 128 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 128 Enable Code 128 Fixed Length 2 This feature specifies Code 128 second fixed length. This applies when Code 128 Length Control is set to fixed-length decoding. If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 128 Stitching Enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
EAN-128 Enable EAN-128 Enable Enables/disables the ability of the scanner to decode EAN-128 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-128 AIM ID This feature enables/disables transmission of the EAN-128 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-128 Enable EAN-128 Label ID This feature specifies an EAN-128 label ID to be added to bar code data.. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-128 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 of 5) Enable Enables/disables the ability of the scanner to decode Interleaved 2 of 5 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Check Character Calculation Enables/disables calculation and verification of an optional Interleaved 2 of 5 check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
I 2 of 5 Check Character Transmission Enables/disables transmission of an optional Interleaved 2 of 5 check character. This feature applies only when I 2 of 5 Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 AIM ID This feature enables/disables transmission of the I 2 of 5 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
I 2 of 5 Label ID This feature specifies an I 2 of 5 label ID to be added to bar code data.. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 of 5 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for I 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
I 2 of 5 Maximum Label Length This feature specifies the maximum allowable length of an I 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when I 2 of 5 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 MAXIMUM LABEL LENGTH below.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Minimum Label Length This feature specifies the minimum allowable length of an I 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when I 2 of 5 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
I 2 of 5 Fixed Length 1 This feature specifies I 2 of 5 first fixed length. This applies when I 2 of 5 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Fixed Length 2 This feature specifies I 2 of 5 second fixed length. This applies when I 2 of 5 Length Control is set to fixed-length decoding. If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 OF 5 FIXED LENGTH 2 below.
I 2 of 5 Stitching Enables/disables stitching for I 2 of 5 labels. When parts of an I 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Codabar Enable Codabar Enable Enables/disables the ability of the scanner to decode Codabar labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Start Stop Character Transmission Enables/disables transmission of Codabar start and stop characters. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Start Stop Character Set This feature selects the format of transmitted Codabar start/stop characters. Options are: • ABCD/TN* E • ABCD/ABCD • abcd/tn* e • abcd/abcd To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below or from the following page representing the desired option. You’ll need to cover any unused bar codes and facing pages to ensure that the scanner reads only the bar code you intend to scan. 3.
Codabar Start Stop Character Set — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Codabar Enable Codabar Start Stop Character Match Enables/disables the requirement that start and stop characters match. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Check Character Calculation Enables/disables calculation and verification of an optional Codabar check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Codabar Enable Codabar Check Character Transmission Enables/disables transmission of an optional Codabar check character. Applies only when Codabar Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Codabar AIM ID This feature enables/disables transmission of the Codabar AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Label ID This feature specifies a Codabar label ID to e added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Codabar Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Codabar. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Maximum Label Length This feature specifies the maximum allowable length of a Codabar label. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Codabar Minimum Label Length This feature specifies the minimum allowable length of a Codabar label. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR MINIMUM LABEL LENGTH below.
Codabar Enable Codabar Fixed Length 1 This feature specifies Codabar first fixed length. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to fixed-length decoding. NOTE Decodable length is four when the optional check character is present. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR FIXED LENGTH 1 below.
Codabar Fixed Length 2 This feature specifies Codabar second fixed length. Length in this case includes start, stop or check and data characters, but does not include full ASCII shift characters. This feature applies when Codabar Length Control is set to fixed-length decoding. NOTE Decodable length is four when the optional check character is present. If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2.
Codabar Enable Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Code 93 Enable Enables/disables the ability of the scanner to decode Code 93 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Enable Code 93 AIM ID This feature enables/disables transmission of the Code 93 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Label ID This feature specifies a Code 93 label ID to be added to bar code data.. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 93 Enable Code 93 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 93. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Maximum Label Length This feature specifies the maximum allowable length of a Code 93 label. Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 MAXIMUM LABEL LENGTH below.
Code 93 Enable Code 93 Minimum Label Length This feature specifies the minimum allowable length of a Code 93 label. Length in this case includes data characters, but does not include start, stop, full ASCII shift, or check characters. This feature applies when Code 93 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Code 93 Fixed Length 1 This feature specifies Code 93 first fixed length. This applies when Code 93 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length.
Code 93 Enable Code 93 Fixed Length 2 This feature specifies Code 93 second fixed length. This applies when Code 93 Length Control is set to fixed-length decoding. If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 93 Stitching Enables/disables stitching for Code 93 labels. When parts of a Code 93 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
MSI/Plessey Enable MSI/Plessey Enable Enables/disables the ability of the scanner to decode MSI/Plessey labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Check Character Calculation Enables/disables calculation and verification of optional MSI/Plessey check characters. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
MSI/Plessey Enable MSI/Plessey Number of Check Characters Specifies number of MSI/Plessey check characters to be calculated and verified. Check characters are always modulus 10. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired number of MSI/ Plessey check characters to be calculated and verified. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Check Character Transmission Enables/disables transmission of optional MSI/Plessey check characters. This feature applies only when MSI/Plessey Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
MSI/Plessey Enable MSI/Plessey AIM ID This feature enables/disables transmission of the MSI/Plessey AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Label ID This feature specifies an MSI/Plessey label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Enable MSI/Plessey Length Control This feature specifies whether variable-length or fixed-length decoding will be set for MSI/Plessey. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Maximum Label Length This feature specifies the maximum allowable length of an MSI/Plessey label. Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This feature applies when MSI/ Plessey Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
MSI/Plessey Enable MSI/Plessey Minimum Label Length This feature specifies the minimum allowable length of an MSI/Plessey label. Length in this case includes check and data characters, but does not include start, stop or full ASCII shift characters. This applies when MSI/Plessey Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
MSI/Plessey Fixed Length 1 This feature specifies MSI/Plessey first fixed length. This applies when MSI/Plessey Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Enable MSI/Plessey Fixed Length 2 This feature specifies MSI/Plessey second fixed length. This applies when MSI/Plessey Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey labels. When parts of an MSI/ Plessey bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Standard 2 of 5 Enable Standard 2 of 5 Enable Enables/disables the ability of the scanner to decode Standard 2 of 5 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 Check Character Calculation Enables/disables calculation and verification of an optional Standard 2 of 5 check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check character in a bar code is treated as data character. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Standard 2 of 5 Enable Standard 2 of 5 Check Character Transmission Enables/disables transmission of an optional Standard 2 of 5 check character. This feature applies only when Standard 2 of 5 Check Character Calculation is enabled. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Standard 2 of 5 AIM ID This feature enables/disables transmission of the Standard 2 of 5 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 Enable Standard 2 of 5 Label ID This feature specifies an Standard 2 of 5 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 of 5 LABEL ID below.
Standard 2 of 5 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Standard 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 Enable Standard 2 of 5 Maximum Label Length This feature specifies the maximum allowable length of a Standard 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when Standard 2 of 5 Length Control is set to variable-length decoding. NOTE Maximum label length should be greater than or equal to minimum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Standard 2 of 5 Minimum Label Length This feature specifies the minimum allowable length of an Standard 2 of 5 label. Length in this case includes check and data characters, but does not include start or stop characters. This feature applies when Standard 2 of 5 Length Control is set to variable-length decoding. NOTE Minimum label length should be less than or equal to maximum label length. To set this feature: 1. Scan the SWITCH bar code. 2.
Standard 2 of 5 Enable Standard 2 of 5 Fixed Length 1 This feature specifies Standard 2 of 5 first fixed length. This applies when Standard 2 of 5 Length Control is set to fixedlength decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 OF 5 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Standard 2 of 5 Fixed Length 2 This feature specifies Standard 2 of 5 second fixed length. This applies when Standard 2 of 5 Length Control is set to fixed-length decoding. NOTE If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 OF 5 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Standard 2 of 5 Enable Standard 2 of 5 Stitching Enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. This applies when Standard 2 of 5 Length Control is set to fixed-length decoding. NOTE To set this feature: 1. Scan the SWITCH bar code. 2.
NOTES 6-280 Magellan® 9500
Appendix A LED/Beeper Indications & Controls Figure A-1 shows the operator’s controls and indicators. The descriptions following identify the use or function of each component. Figure A-1.
Controls and Indicators The control panel consists of three indicator LEDs and three push buttons as described in the following pages. The unit also includes a beeper which can be configured to sound indications of scanning, weighing, and deactivation activities. Since beeper indications are configurable, your unit may not be programmed to sound all the indications listed. For more information, see the Programming chapter of this manual.
Controls and Indicators Table A-1. Scanner and Scale LED Indications LED INDICATION Host Disabled DURATION Scanner (Green) LED 1-second off, 1/ 10-second on Audible low tone 1 second. Field Replaceable Unit (FRU) Warning (Error Mode) FRU Indication Alternating Scanner/Scale (Green/ Yellow) LEDs flash continuouslyb. Scanner (Green) LED flashes a coded sequence in concert with the speaker. COMMENT Host has disabled scanning. Serves notice that a fatal FRU failure has been detected.
Deactivator LED EAS (Tri-Color) LED The Deactivator LED (tri-color, bottom-most) designates EAS deactivation status (see Table A-2). The table also provides information about special beeper indications which can be sounded in response to changes in deactivation status. Table A-2. EAS Indications EAS DEACTIVATION DISABLED INDICATION Deactivation Disabled LED DURATION Deactivation (Tri-color) LED is OFF EAS BEEPER COMMENT OFF Deactivation mode must be selected via programming. Reference EAS Mode.
Controls and Indicators Table A-2. EAS Indications COUPLED MODE ONLY Deactivation Indicated Manual Deactivation in Progress Manual Deactivation Successful Deactivate EAS System When Failed Deactivation (Tri-color) LED flashes Red, then Orange, then returns to Green. Deactivation (Tri-color) LED is lit steadily Green. Deactivation (Tri-color) LED flashes Red, then Orange, then returns to Green. Deactivation (Tri-color) LED is flashing slowly Red.
Table A-2. EAS Indications HYBRID MODE Deactivation (Tri-color) LED flashes Red, then Orange, then returns to Green. Deactivation Indicated High frequency beep An EAS tag has been successfully deactivated. a. Additionally, the FRU LED (7-segment display located in the bottom of the optic cavity — visible through the horizontal scan window) blinks the number ‘9’.
Controls and Indicators Table A-3. Volume/Tone Push Button Functions (Continued) PRESS DURATION FUNCTION COMMENT Increments tone Press the push button for approximately 2 seconds, then release. Each time this is done, the beeper will sound at one of three tones. Stop when the desired tone (high, medium or low) is sounded. 4 Seconds Scanner Diagnostics Modea This mode allows system support personnel to troubleshoot problems with the scanner.
Manual EAS Deactivation Push Button Using the programming bar codes contained in the Product Reference Guide (PRG) the button can be configured to operate always, or only function when the scanner is enabled. PRESS DURATION Momentarya 3 Seconds upon EAS error FUNCTION COMMENT Manually initiates EAS deactivation Place the item with the EAS tag downstreamb of the horizontal scan window and push the button.
Controls and Indicators Scale Zero Push Button The Scale Zero Push Button is used for multiple functions as listed in Table A-4. The Scale Zero Push Button has no function in a “scanner only” model. NOTE Table A-4. Scale Zero Push Button Functions PRESS DURATION FUNCTION COMMENT Momentary Zero Scale When programmed to do so, the yellow LED should be lit when no weight is on the scale, indicating scale at zero. If it is not, press the switch to zero the scale.
Calibration Switch This switch initiates the scale’s calibration routine. A certified weight set is needed to perform the scale calibration steps detailed in Chapter 5, Calibration. This switch is not included in scanners without scale modules. Calibration Switch Seal This seal allows you to secure the Calibration Switch access cover and restrict access to the Calibration Switch. If the calibration seal is broken or missing, you may be prohibited from operating the scale without recertification.
Appendix B Cable Information Introduction The following pages contain pinout information, enabling you to create standard interface cables for use in interconnecting the scanner, scale, external handheld scanner, and POS terminal. General Specifications Wire Requirements • Cable length should not exceed 15 feet. • Wire gauge = Standard for RJ-45 connectors (28-26 AWG). • If run exceeds 15 feet, we recommend 26 AWG wire size.
RS-232 Cable Pinout Scanner Connector Hardware RJ45, 10 Position Cable Pinout Table B-1RS-232 Cable Pinouts B-2 PIN # FUNCTION DESCRIPTION 1 N/C 2 CTS in 3 N/C 4 RTS out Request To Send (output) 5 RxD in Receive Data (Input) 6 TxD out Transmit Data (output) 7 N/C 8 +5V out 9 GND Signal Ground 10 N/C No Connection No Connection Clear To Send (input) No Connection No Connection +5V out Magellan® 9500
RS-232 Cable Pinout — continued RS-232 Cable Pinout — continued Scale Connector Hardware RJ45, 10 Position Cable Pinout Table B-2RS-232 Scale Cable Pinouts PIN # FUNCTION 1 +5V pullup 2 CTS IN 3 N/C 4 RTS OUT 5 RxD IN Receive Data (Input) 6 TxD OUT Transmit Data (output) 7 N/C 8 +5V out 9 Gnd Signal Ground 10 N/C No Connection Product Reference Guide DESCRIPTION +5V pullup Clear To Send (input) No Connection Request To Send (output) No Connection +5V out B-3
IBM Cable Pinout Scanner and Scale Connector Hardware RJ45, 10 Position Cable Pinout Table B-3IBM Cable Pinouts B-4 PIN # FUNCTION DESCRIPTION 1 N/C No Connection 2 N/C No Connection 3 N/C No Connection 4 LINEB 5 N/C 6 LINEA 7 N/C 8 +5V out 9 GND Signal Ground 10 N/C No Connection Line B No Connection Line A No Connection +5V out Magellan® 9500
IBM USB Cable Pinout IBM USB Cable Pinout Scanner and Scale Connector Hardware RJ45, 10 Position Cable Pinout Table B-4IBM USB Cable Pinouts PIN # FUNCTION 1 N/C No Connection 2 N/C No Connection 3 N/C No Connection 4 USB D- 5 N/C 6 USB D+ 7 N/C 8 +5V out 9 GND Signal Ground 10 N/C No Connection Product Reference Guide DESCRIPTION USB DNo Connection USB D+ No Connection +5V out B-5
Auxilliary Port External Handheld Input Connector Hardware RJ45, 10 Position Cable Pinout Table B-5Auxilliary Port Cable Pinouts B-6 PIN # FUNCTION DESCRIPTION 1 +5V pullup 2 CTS in 3 N/C No Connection - Reserved 4 RTS out Request To Send (output) 5 RxD in Receive Data (Input) 6 TxD out Transmit Data (output) 7 N/C 8 +5V out (500mA max) 9 GND Signal Ground 10 N/C No Connection +5V pullup Clear To Send (input) No Connection +5V out Magellan® 9500
Power Cable Power Cable Connector Hardware 6 pin Molex Cable Pinout Table B-6Power Cable Pinouts PIN # FUNCTION 1 EARTH GND Earth Ground 2 SIGNAL GND Signal Ground 3 +5V IN 4 N/C No Connection 5 N/C No Connection 6 +12V IN Product Reference Guide DESCRIPTION +5V in +12V in B-7
Remote Display Connector Hardware 4 pin SDL Cable Pinout Table B-7Remote Display Cable Pinouts B-8 PIN # FUNCTION DESCRIPTION 1 +12V OUT 2 LINE_A_DSPLY LINE A Display 3 LINE_B_DSPLY LINE B Display 4 GND +12V out Ground Magellan® 9500
EAS Comm Port EAS Comm Port EAS Deactivator Control Box Connection Connector Hardware RJ10 Cable Pinout Table B-8EAS Comm Port Cable Pinouts PIN # FUNCTION 1 VCC5 2 EAS DEACT EN~ 3 VCC5 4 EAS DETECT EN~ EAS Detection 5 EAS LBL DETECT EN~ EAS tag Detect 6 GND Signal Ground 7 N/C No Connection 8 EAS TXD EAS Transmit Data 9 EAS RXD EAS Receive Data 10 GND Product Reference Guide DESCRIPTION VCC5 EAS Deactivation VCC5 Signal Ground B-9
NOTES B-10 Magellan® 9500
Appendix C Keypad Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Appendix D Host Commands Accepting Commands from an RS-232 Scanner Host The scanner responds to the following RS-232 commands: COMMAND ASCII HEX COMMENT Enable Scanner E 0x45 Disable Scanner D 0x44 Reset Scanner R 0x52 Not On File Indication F 0x46 Long series of beeps Beep Good Read Tone B 0x42 Beeps if Good Read Beep is enabled Force Good Read Tone 0x01 Beeps regardless of beep setting Bel 0x07 Force Good Read Tone Identification request i 0x69 Returns long responsea Health
NOTES D-2 Magellan® 9500
Appendix E Factory Defaults The following table provides a listing of the most common factory settings for the interfaces shown. Table E-1Factory Default Settings Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) 60 (600ms) Laser Timeout 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) 20 (5 min.) Motor Timeout 40 (10 min.) 40 (10 min.) 40 (10 min.) 40 (10 min.) 40 (10 min.) 40 (10 min.
Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB 1 (after transmit) 1 (after transmit) 1 (after transmit) 1 (after transmit) 1 (after transmit) 1 (after transmit) 0 (disable) 1 (enable) 0 (disable) 1 (enable) 1 (enable) 1 (enable) Scale Country Mode 0 (US) 0 (US) 0 (US) 0 (US) 0 (US) 0 (US) Scale Enforced Zero Return 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Scale Interface Type 4 (RS-232 SASI) 4 (RS-232 SASI) 4 (RS-232 SASI) 7 (RS-232 si
Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB EAS Deactivation Duration — Coupled 50 (500ms) 50 (500ms) 50 (500ms) 50 (500ms) 50 (500ms) 50 (500ms) EAS Deactivation Duration — Retry 50 (500ms) 50 (500ms) 50 (500ms) 50 (500ms) 50 (500ms) 50 (500ms) EAS Deactivation Duration — Manual 100 (5sec) 100 (5sec) 100 (5sec) 100 (5sec) 100 (5sec) 100 (5sec) Maximum HostTransmitted Message Length 0 (no limit) 0 (no limit) 0 (no limit) 0 (no limit) 0 (no limit) 0 (no limit) Numbe
Aux RS-232 WincorNixdorf Single Cable RS-232 Number of Stop Bits 0 (1 stop bit) 0 (1 stop bit) 0 (1 stop bit) 0 (1 stop bit) RS-232 Parity 0 (none) 0 (none) 2 (odd) 2 (odd) 0 (disable) 0 (disable) 1 (enable CTS flow) 0 (none) 0 (none) 0 (none) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) RS-232 Hardware Control RS-232 Intercharacter Delay RS-232 Software Flow Control RS-232 Host Echo RS-232 Host Echo Quiet Interval 1 (10ms) 1 (10ms) RS-232 Ignore Host Commands 0 (
Aux RS-232 WincorNixdorf RS-232 Retry on ACK NAK Timeout 1 (enable) 1 (enable) 1 (enable) RS-232 ACK NAK Timeout Value 1 (200ms) 1 (200ms) 1 (200ms) RS-232 ACK NAK Retry Count 3 resets 3 resets 3 resets RS-232 ACK NAK Error Handling 0 (ignore errors) 0 (ignore errors) 0 (ignore errors) RS-232 Label ID Control 1 (enable as prefix) 1 (enable as prefix) 1 (enable as prefix) Single Cable RS-232 Scanner Only Protocol IBM 17 IBM USB 1 (enable) 1 (enable) 1 (enable as prefix) 0 (scanne
Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB UPC-A Number System Character Transmission 0 (disable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) UPC-A Check Character Transmission 1 (enable) 1 (enable) 1 (enable) 0 (disable) 1 (enable) 1 (enable) Expand UPC-A to EAN-13 0 (disable) 0 (disable) 1 (enable) 0 (disable) 0 (disable) 0 (disable) UPC/EAN AIM ID 0 (disable) 0 (disable) 0 (disable) UPC-A Label ID 4100("A") 4100("A") 4100("A") 4100("A") UPC-A 2-Dig
Aux RS-232 WincorNixdorf Single Cable UPC-E 128 Supplemental Label ID 4500("E") 4500("E") 4300("C") 4500("E") EAN-13 Enable 1 (enable) 1 (enable) 1 (enable) EAN-13 First Character Transmission 1 (enable) 1 (enable) EAN-13 Check Character Transmission 1 (enable) EAN-13 ISBN Conversion Enable IBM 17 IBM USB 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 1 (enable) 0 (disable) 1 (enable) 1 (enable) 0 (disable) 0 (disable) 0 (disable)
Aux RS-232 WincorNixdorf Single Cable 4646 ("FF") 4646 ("FF") 4200 ("B") 4646 ("FF") EAN-8 Decoding Levels 2 (Slightly More Aggresive) 2 (Slightly More Aggresive) 2 (Slightly More Aggresive) UPC/EAN Reconstruction 0 (disable) 0 (disable) Price Weight Check 0 (disable) Enable EAN Two Label IBM 17 IBM USB 2 (Slightly More Aggresive) 2 (Slightly More Aggresive) 2 (Slightly More Aggresive) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disabl
Aux RS-232 WincorNixdorf Single Cable 5234 ("R4") 5234 ("R4") 4500 ("E") 5234 ("R4") RSS Expanded Enable 0 (disable) 0 (disable) 0 (disable) RSS Expanded EAN128 Emulation 0 (disable) 0 (disable) RSS Expanded 2D Component Enable 0 (disable) RSS Expanded AIM ID RSS Expanded Label ID IBM 17 IBM USB 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable)
Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB Code 39 Full ASCII 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Code 39 AIM ID 0 (disable) 0 (disable) 0 (disable) Code 39 Label ID 2A00 ("*") 2A00 ("*") 4D00 ("M") 4231 ("B1") Code 39 Length Control 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) 0 (variable) Code 39 Maximum Label Length 50 50 50 50 50 50 Code 39 Minimum Label Length 2 2 2 2 2 2 Code 39 Fixed Length 1
Aux RS-232 WincorNixdorf Single Cable Code 128 AIM ID 0 (disable) 0 (disable) 0 (disable) Code 128 Label ID 2300 ("#") 2300 ("#") 4B00 ("K") 4233 ("B3") Code 128 Length Control 0 (variable) 0 (variable) 0 (variable) Code 128 Maximum Label Length 80 80 Code 128 Minimum Label Length 2 Code 128 Fixed Length 1 Code 128 Fixed Length 2 IBM 17 IBM USB 0 (variable) 0 (variable) 0 (variable) 80 80 80 80 2 2 2 2 2 8 8 8 8 8 8 14 14 14 14 14 14 Code 128 Stitching 1 (en
Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB I 2 of 5 Maximum Label Length 50 50 50 50 50 50 I 2 of 5 Minimum Label Length 6 6 6 6 6 6 I 2 of 5 Fixed Length 1 10 10 10 10 10 10 I 2 of 5 Fixed Length 2 0 0 0 0 0 0 I 2 of 5 Stitching 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Codabar Enable 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Codabar Start Stop Character Transmission 0 (disable) 0 (disabl
Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB Codabar Fixed Length 1 8 8 8 8 8 8 Codabar Fixed Length 2 14 14 14 14 14 14 Codabar Stitching 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Code 93 Enable 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Code 93 AIM ID 0 (disable) 0 (disable) 0 (disable) Code 93 Label ID 2600 ("&") 2600 ("&") 4C00 ("L") 2600 ("&") Code 93 Length Control 0 (variable) 0 (variable)
Aux RS-232 WincorNixdorf Single Cable 4000 ("@") 4000 ("@") 4F00 ("O") 4000 ("@") MSI/Plessey Length Control 0 (variable) 0 (variable) 0 (variable) 0 (variable) MSI/Plessey Maximum Label Length 16 16 16 16 MSI/Plessey Minimum Label Length 4 4 4 4 MSI/Plessey Fixed Length 1 7 7 7 7 MSI/Plessey Fixed Length 2 8 8 8 8 MSI/Plessey Stitching 0 (disable) 0 (disable) 0 (disable) 0 (disable) Standard 2 of 5 Enable 0 (disable) 0 (disable) 0 (disable) Standard 2 of 5 Check Ch
Aux RS-232 WincorNixdorf Single Cable IBM 17 IBM USB Standard 2 of 5 Minimum Label Length 6 6 6 6 6 6 Standard 2 of 5 Fixed Length 1 10 10 10 10 10 10 Standard 2 of 5 Fixed Length 2 0 0 0 0 0 0 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) 0 (disable) Standard 2 of 5 Stitching Product Reference Guide E-15
NOTES E-16 Magellan® 9500
Appendix F Handheld Data Format Requirements This appendix provides application notes to describe the general format of data that can be accepted by the scanner through the auxilliary port as transmitted from a handheld scanner. Handheld Data Format Requirements General • 9600 bps, 8 data bits, 1 stop bit, no parity. • RTS is used to "bracket" the data received from the handheld: RTS must be asserted high during data transmission, and de-asserted after label transmission is complete.
Datalogic Handheld Data Format Requirements The following sections describe label transmission formats that are typically observed in factory configurations of Datalogic handheld scanners. RSS-14 • Prefix must be ASCII characters ‘R4’ • Check character must be included in label • Application identifier “01” must follow the prefix and preceed the base label • Label length excluding prefix characters must be 16 characters.
UPC-A with 5-Digit Supplemental • Number system must be included in label data • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII character 'A' - total length including prefix must be 18 • Example: 'A06099201118712345' UPC-A with Code 128 Supplemental • Number system must be included in label data. • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label.
UPC-E with 2-Digit Supplemental • Number system must be included in label data. • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label. • Prefix must be an ASCII character 'E' - total length including prefix must be 11. • Example: 'E0998875012'. UPC-E with 5-Digit Supplemental • Number system must be included in label data. • Check digit must be included in label data and is assumed to be correct.
EAN-8 • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII characters 'FF' - total length including prefix must be 10 • Example: 'FF00210126' EAN-8 with 2-Digit Supplemental • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label. • Prefix must be an ASCII characters 'FF' - total length including prefix must be 12. • Example: 'FF0021012612'.
EAN-13 • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII character 'F'- total length including prefix must be 14 • Example: 'F1101234567891' EAN-13 with 2-Digit Supplemental • Check digit must be included in label data and is assumed to be correct • Supplemental data is appended to base label • Prefix must be an ASCII character 'F'- total length including prefix must be 16 • Example: 'F110123456789112' EAN-13 with 5-Digit Supplemental • Check
Code 39 • Check character must be included in label data. • Label length including start, stop and check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Start and stop characters "*" must be included in label. • Prefix must be an ASCII character '*'. • Example : '**Code 39.TEST*'. Code 39-Pharmacode • Check character must be included in label data.
Codabar • Check character must be included in label data. • Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character '%'. • Start stop character sets must meet the matching requirement set forth by the scanner configuration item Codabar Start Stop Character Match.
MSI/Plessey • Check character must be included in label data. • Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character '@'. • Example: '@144769254'. Code 93 • Prefix must be an ASCII character '&'.
AIM Formats AIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM specifies one identifier for UPC-A, UPC-E and EAN-13 labels, UPC-A, UPC-E and EAN-13 will be received from the handheld and transmitted by the scanner as EAN-13. The ']' character must be the first character received in the label transmission from the handheld. The following sections describe the prefix strings and identify what specific label characteristics can be supported.
2-Digit Supplemental • Supplemental data is appended to any EAN base label. • Prefix must be ASCII characters ']E1'. • length of Supplemental data including prefix must be 5. Total required length is 21 for EAN-13 and 16 for EAN-8. • Examples: addon portion is highlighted data is underlined.
Code 128 Supplemental • Supplemental data is appended to any EAN base label. • Prefix must be ASCII characters ']C0'. • length of Supplemental data including prefix is variable but must be at least 9. • Examples: addon portion is highlighted data is underlined.
Codabar • Check character must be included in label data. • Label length including check character and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be ASCII characters ']F0'. • Start stop character sets must meet the matching requirement set forth by the scanner configuration item Codabar Start Stop Character Match.
RSS-14 • Prefix must be ASCII characters ']e0'. • Check character must be included in label. • Label length excluding prefix characters must be 14 characters. • Example: ']e001044123456789'. RSS Expanded • Prefix must be ASCII characters ']e0'. • Label length excluding prefix characters must be at least 1 character. Maximum length is the maximum label size supported by the scanner. • Example: ']e001900123456789083103001750'. I 2 of 5 F-14 • Check character must be included in label data.
Code 128 / EAN128 • Prefix must be either ASCII characters ']C0', ']C1' or ']C2'. • Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • If EAN-128 Symbology is Enabled and prefix is ']C1', label will be identified as an EAN128 otherwise it is identified as a Code 128. • A prefix of ']C0' designates that no function code is present in the 1st or 2nd character position.
NOTES F-16 Magellan® 9500
ASCII Character Set The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters. Table 1 ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No.
Australia Japan Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Latin America Datalogic Scanning Sarl Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Singapore Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.