GRYPHON™ BT Quick Reference 1
DATALOGIC UK/US USING GRYPHON™ BT SERIES READERS Gryphon™ BT series readers, together with a Bluetooth® compatible remote device, build a Cordless Reading System for the collection, decoding and transmission of barcoded data. The Gryphon™ BT (Gryphon™ Bluetooth®) reader is a CCD wireless barcode scanner communicating in the 2.4 GHz ISM band and using the Serial Port Profile (SPP).
GRYPHON™ BT UK/US CHARGING THE BATTERIES By placing the reader onto the C-GRYPHON battery charger it is possible to charge the Gryphon™ BT batteries. Make sure the charging LED goes on. The LEDs positioned on the cradle signal the charge status, as described in the following table: LED STATUS Red On = C-GRYPHON is powered. Blinking = C-GRYPHON receives commands from the Host. On = the battery charge is in progress. Green On = the battery is completely charged.
DATALOGIC UK/US Changing the Batteries When the above procedure is no longer effective, the batteries must be changed. To change the batteries of your reader, unscrew the battery cover screw, replace the old batteries with new ones, then insert the cover in the handle and screw it back into place. (See the following figures). + CAUTION Dispose of the batteries as required by the relevant laws in force.
GRYPHON™ BT UK/US GRYPHON™ BT OPERATION RADIO CONNECTION Gryphon™ BT as Slave A Gryphon™ BT is Slave when it sends barcodes to a Master remote Bluetooth® device such as a PC, Laptop, PDA, etc, which has initialized the communication. Once set as Slave, a Gryphon™ BT reader requires no particular configuration for communication, however some radio parameters can be set to increase system performance and data transmission security, see the Gryphon™ BT Reference Manual on the configuration CD-ROM.
DATALOGIC UK/US Gryphon™ BT as Master A Gryphon™ BT is Master when the remote Bluetooth® device is Slave, i.e. with a Bluetooth® barcode printer. Once set as Master, a Gryphon™ BT reader must be configured to recognize the address of the Slave device to which it wants to communicate. By default, at startup the reader initializes the communication with the Slave. If the connection is successful, the reader can send barcodes to the Slave device.
GRYPHON™ BT UK/US GRYPHON™ BT CONFIGURATION Configure the Gryphon™ BT by choosing one of the two procedures below and reading the codes in the given sequence. GRYPHON™ BT AS SLAVE 1. Restore Gryphon™ BT default i i i 2. Pk Pk Pk Set Gryphon™ BT as Slave i i i 25 ?k 25 ?k 25 ?k YOUR READER IS NOW READY TO BE DISCOVERED (CONNECTED VIA RADIO) BY A BLUETOOTH® MASTER DEVICE AND READ BARCODES.
DATALOGIC UK/US GRYPHON™ BT AS MASTER Note: for the hexadecimal character selection of step 4, use the table at the end of this manual. 1. Restore Gryphon™ BT default i i i 2. 25 Dk 25 Dk 25 Dk Enter configuration i i i 4. Pk Pk Pk Set Gryphon™ BT as Master i i i 3. k k k Set Remote Bluetooth® Device Address (slave) i242k i242k i242k + 12 hexadecimal characters for the remote Bluetooth® device address 5. Exit and Save configuration i i i 6.
GRYPHON™ BT UK/US GRYPHON™ BT DEFAULT CONFIGURATION DATA FORMAT code identifier disabled, field adjustment disabled, code length tx not transmitted, character replacement disabled, address stamping = disabled, address delimiter = disabled. POWER SAVE scan rate 270 scans/s. READING PARAMETERS operating mode hand-held, hardware trigger, trigger active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per cycle, safety time 0.
UK/US DATALOGIC ADVANCED FORMATTING PARAMETERS concatenation disabled, no advanced formats defined, Zebra printer formatting = disabled. RADIO PARAMETERS radio protocol timeout = 3 seconds, transmission retry = none, no ACK/NACK protocol nor frame packing, power-off timeout = 4 hours, userfriendly name = "Gryphon BTx00 ", beeper control for radio response = good decode and good reception, Bluetooth® role = Slave, destination address = 000000000000, auto-connection = enabled, auto-reconnection = enabled.
GRYPHON™ BT UK/US SERIAL CONFIGURATION OPTIONS In addition to the battery charge function C-GRYPHON can be connected to a PC by means of an RS232 interface to send new configuration strings from the PC to the reader (i.e. using DL Sm@rtSet™), to upgrade application software onto the Gryphon™ BT reader or optionally when performing the copy configuration procedure (see the Gryphon™ BT Reference Manual).
DATALOGIC UK/US TECHNICAL FEATURES Electrical Features Battery Type Time of recharge NiMh Operating autonomy (typ. continuous reading) Max scan rate Indicators Optical Features Sensor Illuminator Wavelength Max. LED Output Power LED Safety Class Reading field Max. resolution PCS minimum 2 AA NiMh* batteries 1.2 V – 1850 mAh 4 hours 25.000 reads - NiMh 270 scans/sec LED, Good Read Spot, Beeper CCD solid state (3648 pixels) LED array 630 ~ 670 nm 0.33 mW Class 1 EN 60825-1 see reading diagram (p.47) 0.
GRYPHON™ BT UK/US C-GRYPHON Electrical Features Supply voltage Power consumption Indicators Time of recharge Environmental Features Working temperature Storage temperature Humidity Protection class Communications Interface Baud Rate Data Bits Stop Bit Parity Mechanical Features Weight Dimensions Material * 9..28 Vdc max.
DATALOGIC UK/US TROUBLESHOOTING PROBLEM A beep or a LED blink signals an interruption of the radio communication with the remote Bluetooth® device. SOLUTION • It is possible that the distance from the remote Bluetooth® device is more than 10 m or that an obstacle interrupted the communication. • Restart the radio communication. PROBLEM The reader is Master and is not able to initialize radio communication with the remote Bluetooth® device server.
GRYPHON™ BT UK/US PROBLEM The remote Bluetooth® device discovers a Gryphon™ BT within its range of radio communication but is not able to communicate with it. SOLUTION • Make sure that: - the remote Bluetooth® device has not any communication protection (i.e. a password); - the protocol version is compatible with Gryphon™ BT's. PROBLEM It seems that the Gryphon™ BT radio communication range is less than 10 m. SOLUTION • Check that there are no obstacles to radio transmission between the devices.
UK/US DATALOGIC SERVICES AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.
GRYPHON™ BT UK/US COMPLIANCE This device must be opened by qualified personnel only. The batteries must be removed before opening the device. Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules.
DATALOGIC UK/US GRYPHON™ BT SERIES GRYPHON BT100 (STANDARD) M100 (STD) - Reading Zones (10° skew angle) 15 0.13 mm (5 mils) 10 5 CODE 39 0.076 mm (3 mils) 0 CODE 39 0.13 mm (5 mils) EAN13 M=1 0.33 mm (13 mils) CODE 39 0.50 mm (20 mils) -5 -10 -15 0 5 10 15 20 25 30 35 (cm) GRYPHON BT200 (PDF) M200 (PDF) - Reading Zones (10° skew angle) 10 0.13 mm (5 mils) 5 CODE39 CODE39 0.076 mm 0.13 mm (3 mils) (5 mils) 0 EAN13 M=1 0.33 mm (13 mils) CODE39 0.
GRYPHON™ BT UK/US HEX NUMERIC TABLE i k i k i k i k i k i k 0 1 i k i k i k i k i k i k 2 3 i k i k i k i k i k i k 4 5 i k i k i k i k i k i k 6 7 i k i k i k i k i k i k 8 9 i"#k i"#k i"#k i#$k i#$k i#$k A B i$%k i$%k i$%k i%&k i%&k i%&k C D i&'k i&'k i&'k i'(k i'(k i'(k E F 19
DATALOGC S.p.A.