OM-GRYPHON™ SERIES QUICK REFERENCE
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy OM-GRYPHON™ Ed.: 11/2005 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
CONTENTS Updates and Language Availability.....................................................................iv Using OM-GRYPHON™ Radio Cradle ............................................................... 1 System Connections ........................................................................................... 2 Connecting and Disconnecting the OM-GRYPHON™ Interface Cable ............. 2 OM-GRYPHON™ Configuration .........................................................................
UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to : www.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a : www.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française.
OM-GRYPHON™ USING OM-GRYPHON™ RADIO CRADLE The OM-GRYPHON™ cradle, paired with one Gryphon™ M series reader, builds a Cordless Reading System for the collection, decoding and transmission of barcoded data. USB multi-standard interface models can be connected to a Host PC through a USB, RS232, Wedge or Pen emulation cable. IBM models can be connected to an IBM 46xx Terminal, a USB or an RS232 interface. All models are suited for single-cradle layouts.
DATALOGIC SYSTEM CONNECTIONS Connections should always be made with power off! CAUTION You can connect the OM-GRYPHON™ cradle to the Host through the dedicated connector, using the cable corresponding to the desired interface type. CONNECTING AND DISCONNECTING OM-GRYPHON™ INTERFACE CABLE THE To connect the OM-GRYPHON™ : 1. Connnect the OM-GRYPHON™ to the appropriate interface cable which must be simply plugged into the Host connector on the base of the cradle. 2.
OM-GRYPHON™ RS232 CONNECTION USB CONNECTION IBM USB POS CONNECTION WEDGE CONNECTION 3
DATALOGIC WEDGE CONNECTION PEN CONNECTION IBM 46XX TERMINALS – PORT 9B/PORT 5B CONNECTION 4
OM-GRYPHON™ OM-GRYPHON™ CONFIGURATION The OM-GRYPHON™ configuration can be performed in two ways: either by sending configuration strings from the Host via the RS232 or USB-COM interface or by reading configuration barcodes with the Gryphon™ M reader. SERIAL/USB COM CONFIGURATION By connecting the OM-GRYPHON™ to a PC through an RS232 or USB interface cable it is possible to send configuration strings from the PC to OMGRYPHON™.
DATALOGIC USB INTERFACE CONFIGURATION The USB interface is compatible with: - Windows 98 (and later) Mac SO 8.0 (and later) IBM POS for Windows 4690 Operating System START-UP As with all USB devices, upon connection, the Host performs several checks by communicating with the OM-GRYPHON™. Before the OM-GRYPHON™ is ready, the correct USB driver must be loaded.
OM-GRYPHON™ USB INTERFACE SELECTION USB-KBD (default) Ì$+UA03$-:Î USB-KBD-ALT-MODE Ì$+UA04$-@Î USB-KBD-APPLE Ì$+UA05$-FÎ USB-COM* Ì$+UA02$-4Î USB-IBM-Table Top Ì$+UA00$-(Î USB-IBM-Hand Held Ì$+UA01$-.Î * When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web site http://www.datalogic.com.
DATALOGIC USB KEYBOARD NATIONALITY USB-KBD users should NATIONALITY codes. select one of the following Belge Ì$+FJ7$-8Î Deutsch Ì$+FJ3$-$Î English Ì$+FJ4$-)Î Español Ì$+FJ6$-3Î Français Ì$+FJ2$-ÊÎ Italiano Ì$+FJ1$-ÅÎ Japanese Ì$+FJ8$-.
OM-GRYPHON™ RS232 INTERFACE SELECTION Read the OM-GRYPHON™ restore default code, then read the interface selection code for your application: RESTORE OM-GRYPHON™ DEFAULT Ì$+RX0$-qÎ RS232 INTERFACE Standard Ì$+CP0$-$Î POS TERMINALS Nixdorf Mode A Ì$+CM2EC0$->Î Fujitsu Ì$+CM1$-ÈÎ ICL Mode Ì$+CM0$-ÃÎ 9
DATALOGIC WEDGE INTERFACE SELECTION Read the OM-GRYPHON™ restore default code, then read the interface selection code for your application: RESTORE OM-GRYPHON™ DEFAULT Ì$+RX0$-qÎ WEDGE INTERFACE IBM AT or PS/2 PCs Ì$+CP500$-aÎ IBM XT Ì$+CP503$-vÎ PC Notebook Ì$+CP505$-ÈÎ IBM SURE1 Ì$+CP506$-$Î IBM Terminal 3153 Ì$+CP504$-}Î 10
OM-GRYPHON™ WEDGE INTERFACE (CONTINUED) IBM Terminals 31xx, 32xx, 34xx, 37xx: To select the interface for these IBM Terminals, read the correct key transmission code. Select the keyboard type if necessary (default = advanced keyboard).
DATALOGIC WEDGE INTERFACE (CONTINUED) WYSE TERMINALS ANSI Keyboard Ì$+CP509$-9Î PC Keyboard Ì$+CP510$-gÎ ASCII Keyboard Ì$+CP511$-nÎ VT220 style Keyboard Ì$+CP514$-ÇÎ DIGITAL TERMINALS VT2xx/VT3xx/VT4xx Ì$+CP512$-uÎ APPLE APPLE ADB Bus Ì$+CP513$-|Î 12
OM-GRYPHON™ WEDGE KEYBOARD NATIONALITY If you selected the Wedge interface, you should also read among the following codes the one that matches your Keyboard Nationality: Belge Ì$+FJ7$-8Î Deutsch Ì$+FJ3$-$Î English Ì$+FJ4$-)Î Español Ì$+FJ6$-3Î Français Ì$+FJ2$-ÊÎ Italiano Ì$+FJ1$-ÅÎ Svenskt Ì$+FJ5$-.
DATALOGIC PEN INTERFACE SELECTION Read the OM-GRYPHON™ restore default code, then read the interface selection code for your application: RESTORE OM-GRYPHON™ DEFAULT Ì$+RX0$-qÎ PEN INTERFACE Ì$+CP6$-BÎ IBM 46xx TERMINAL INTERFACE SELECTION Read the OM-GRYPHON™ restore default code, then read the interface selection code for your application: RESTORE OM-GRYPHON™ DEFAULT Ì$+RX0$-qÎ PORT 9B 4501 Protocol Ì$+CP800$-pÎ (typical) 1520 Protocol Ì$+CP801$-wÎ PORT 5B 1520 Protocol Ì$+CP801$-wÎ (typical) 4501
OM-GRYPHON™ IBM 46XX TERMINAL DATA FORMATTING To select the data formatting for these IBM Terminals, read one of the code selections below. (default = IBM Standard).
DATALOGIC OM-GRYPHON™ DEFAULT CONFIGURATION USB DEFAULT SETTINGS DATA FORMAT: code identifier disabled, code length not transmitted, character replacement disabled, address stamping disabled, address delimiter disabled. USB KEYBOARD: USA keyboard, inter-character and inter-code delays disabled. USB COM: handshaking disabled, delay disabled, rx timeout 5 sec., ack/nack disabled, FIFO enabled, serial trigger lock disabled.
OM-GRYPHON™ WEDGE DEFAULT SETTINGS USA keyboard, caps lock off, caps lock auto-recognition enabled; num lock unchanged, inter-character and intercode delay disabled. DATA FORMAT: code identifier disabled, code length not transmitted, no header, terminator = ENTER, character replacement disabled, address stamping disabled, address delimiter disabled.
DATALOGIC OPERATING TEST Read the TEST codes below. EAN-8 1234 5670 EAN-13 1 234567 000992 Code 39 (Normal) 1 7 1 6 2 Code 128 t e s t Interleaved 2 of 5 0123456784 PDF417 DATALOGIC PDF417 Test Code YOUR SYSTEM IS NOW READY TO READ CODES AND TO SEND THE DATA TO THE HOST. To change the defaults refer to the "Gryphon™ Software Configuration Manual", part number 90ACC1780, or to the DL Sm@rtSet™ Configuration program, both downloadable from the website.
OM-GRYPHON™ COPY CONFIGURATION This procedure allows using a previously configured Gryphon™ M reader (Master) to send its configuration directly to other devices of the same type (Slaves) by means of a single OM-GRYPHON™. Proceed as follows: 1. With the master Gryphon™ M (correctly configured reader), read the Copy Configuration barcode below. Then, place it onto the OM-GRYPHON™ cradle within 10 seconds. The reader will beep indicating the configuration has been copied. Copy Configuration Ì$+ZZ0$-*Î 2.
DATALOGIC BATTERY SELECTION Battery selection is required only when the Gryphon™ M reader has an Alkaline battery and you want to use OM-GRYPHON™ either for serial configuration, software upgrades or to hold Gryphon™ M. Since this type of battery must not be charged it is necessary to disable the OM-GRYPHON™ charge function by following the procedure: 1.
OM-GRYPHON™ TECHNICAL FEATURES OM-GRYPHON™ Electrical Features Supply voltage Power consumption LED Indicators Time of recharge Radio Features 9..28 Vdc max. 8 W (charging) * Battery charging red Charge completed green Power / Data yellow From 3 to 5 hours European Models USA Models Working Frequency 433.92 Mhz 910 Mhz Bit rate 19200 baud 36800 baud Range (in open air) RF Modulation Max number of devices per base station Max number of devices in the same reading area 30 m. 15 m.
DATALOGIC WARRANTY Datalogic warranties this product against defects in workmanship and materials, for a period of 24 months from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product, these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
OM-GRYPHON™ FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. This device contains FCC ID OMJ0015.
DATALOGIC S.p.A.