OM-GRYPHON™ CONFIGURATION
The OM-GRYPHON™ configuration can be performed in two ways: either by
sending configuration strings from the Host via the RS232 or USB-COM
interface or by reading configuration barcodes with the Gryphon™ M reader.
SERIAL/USB COM CONFIGURATION
By connecting the OM-GRYPHON™ to a PC through an RS232 or USB
interface cable it is possible to send configuration strings from the PC to OM-
GRYPHON™. Using this method you can also send new configuration strings
from the PC to the reader or upgrade application software onto the Gryphon™
M reader.
CONFIGURATION BARCODES
Once you have performed system connection and Gryphon™ M reader
configuration, you can configure the OM-GRYPHON™ cradle by reading
configuration barcodes. Apply power to the OM-GRYPHON™.
For the Gryphon™ M configuration refer to the “Gryphon™ M Quick Reference”.
To configure the OM-GRYPHON™ using the Gryphon™ M reader (the one
paired to the cradle with the Bind command), follow the procedure according to
the Interface selected.
INTERFACE SELECTION
Follow the procedure to configure the interface required by your application.
USB multi-standard interface models:
• USB Interface
• RS232 Interface
• Wedge Interface
• Pen Interface
IBM models:
• USB
• RS232 Interface
• IBM 46xx terminal Interface