READER DEFAULT CONFIGURATION
DATA FORMAT
code identifier disabled (enabled for POS terminals), field adjustment disabled,
code length tx not transmitted, character replacement disabled, address
stamping disabled; address delimiter disabled
POWER SAVE
sleep state/USB suspend disabled, enter sleep timeout = 0.6 sec
READING PARAMETERS
hand-held operation = hardware trigger, stand operation = automatic, trigger
active level, no timeout, Flash On = 1 sec, Flash Off = 0.6 sec, one read per
cycle, safety time 0.5 sec, beeper intensity high, tone 2, beeper type monotone,
beeper length short, good read spot duration medium, automatic operation
aiming light enabled
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control enabled, Puzzle
Solver™ disabled, decoding safety = one read
CODE SELECTION
Enabled codes
EAN 8/EAN 13 / UPC A/UPC E without ADD ON
check digit transmitted, no conversions
Interleaved 2/5
check digit control and transmission, variable length code; 4-99 characters
Standard Code 39
no check digit control, variable length code; 1-99 characters
Code 128
variable length code; 1-99 characters
EAN 128, ISBT128, Code 93, Codabar, pharmaceutical codes, MSI,
Plessey, Telepen, Delta IBM, Code 11, Code 16K, Code 49, RSS Codes
ADVANCED FORMATTING PARAMETERS
concatenation disabled, no advanced formats defined
RADIO PARAMETERS
radio protocol timeout = 2 seconds, power-off timeout = 4 hours, single store
disabled, beeper control for radio response = normal
18