Datalogic Mobile S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara di Reno Bologna - Italy Datalogic Memor™ - User's Manual Ed.: 07/2007 ALL RIGHTS RESERVED Datalogic Mobile reserves the right to make modifications and improvements without prior notification. Datalogic Mobile shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
CONTENTS DATALOGIC END USER LICENSE AGREEMENT ............................v REFERENCES...................................................................................vii Conventions ....................................................................................... vii Reference Documentation ................................................................. vii Services and Support......................................................................... vii SAFETY REGULATIONS ........................
.6.2 3.6.3 3.6.4 3.7 3.7.1 3.7.2 3.7.3 3.8 Registry ............................................................................................. 25 Files Admin ....................................................................................... 26 Wireless Communications................................................................. 28 Windows Connections....................................................................... 29 Microsoft® ActiveSync®..................................................
DATALOGIC END USER LICENSE AGREEMENT BY DOWNLOADING OR INSTALLING THE SOFTWARE, OR BY USING DATALOGIC EQUIPMENT THAT INCLUDES THIS SOFTWARE, YOU ARE CONSENTING TO BE BOUND BY THIS AGREEMENT. IF YOU DO NOT AGREE TO ALL OF THE TERMS OF THIS AGREEMENT, THEN DO NOT DOWNLOAD, INSTALL, USE THE SOFTWARE NOR DATALOGIC EQUIPMENT.
. Protection of Information. Customer agrees that aspects of the Software and associated documentation, including the specific design and structure of individual programs, constitute trade secrets and/or copyrighted material of Datalogic. Customer shall not disclose, provide, or otherwise make available such trade secrets or copyrighted material in any form to any third party without the prior written consent of Datalogic.
REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Datalogic Memor™ mobile computer. “Mobile computer” and "Datalogic Memor™" refer to Datalogic Memor™ mobile computer. “You” refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Datalogic Memor™ mobile computer. REFERENCE DOCUMENTATION For further information regarding Datalogic Memor™ refer to the SDK Help on-Line.
SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Datalogic Memor™ mobile computer. The user is responsible for any damages caused by incorrect use of the equipment or by inobservance of the indication supplied in this manual. GENERAL SAFETY RULES − Use only the components supplied by the manufacturer for the specific Datalogic Memor™ being used.
LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both laser models and the Datalogic Memor™ Imager Aiming System. Laser output window AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE This product complies with 21 CFR Subchapter J CAUTION-CLASS 2 LASER LIGHT WHEN OPEN - DO NOT STARE INTO BEAM LASER LIGHT - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1.
ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mobile computer. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device.
NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu öffnen. Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschrieben werden, können ein gefährliches Laserlicht verursachen. ACHTUNG Der Produkt benutzt eine Laserdiode.
La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede causar una exposición peligrosa a la luz láser visible. ATENCIÓN El aparato utiliza un diodo láser a baja potencia. No son notorios daños a los ojos humanos a consecuencia de una exposición de corta duración. Eviten de mirar fijo el rayo láser así como evitarían cualquiera otra fuente de luminosidad intensa, por ejemplo el sol.
DEUTSCH Wenden Sie sich an die für Radiofrequenzgeräte zuständige Behörde Ihres Landes, um zu prüfen ob es Einschränkungen gibt, oder eine Lizenz erforderlich ist. Weitere Informationen finden Sie auf der Web Seite: http://europa.eu.int/comm/enterprise/rtte/spectr.htm. ESPAÑOL Contacta la autoridad competente para la gestión de los dispositivos de radio frecuencia de tu país, para verificar cualesquiera restricciones o licencias posibles requerida.
Informazione degli utenti ai sensi della Direttiva Europea 2002/96/EC L’apparecchiatura che riporta il simbolo del bidone barrato deve essere smaltita, alla fine della sua vita utile, separatamente dai rifiuti urbani.
Información para el usuario de accuerdo con la Directiva Europea 2002/96/CE Al final de su vida útil, el producto marcado con un simbolo de contenedor de bassura móvil tachado no debe eliminarse junto a los desechos urbanos.
GENERAL VIEW G B K C A H F I D J E A) B) C) D) E) F) Transflective 64K Color Display Good Read or User Programmable LED Charging Status LED Scan Key Keyboard Radio Status LED G) Strap with Stylus Holder H) Laser Safety Label I) Product Label (under battery) J) Battery Pack K) ON/OFF Power Key N O P M L) M) Data Capture/Laser Output Window * DC Charger Connector * Remove protective film cover before use.
INTRODUCTION 1 1.1 1 INTRODUCTION DATALOGIC MEMOR™ DESCRIPTION The Datalogic Memor™ is a pocket-sized Windows powered mobile computer. This extremely compact, lightweight, and versatile device, combines fully integrated automatic data capture (1D bar code) and wireless communication capabilities (Bluetooth® or 802.11 b/g), supporting nearly any application.
DATALOGIC MEMOR™ 1 1.3 PACKAGE CONTENTS The Datalogic Memor™ package contains: − 1 Datalogic Memor™ mobile computer − 1 AC/DC power supply − 1 EU plug adapter − 1 standard Mini USB cable − 1 CD-ROM Datalogic-NET SDK (Windows CE 5.
INTRODUCTION 1.4 1 INSERTING AN SD CARD Datalogic Memor™ provides the possibility to add an SD memory storage card. To access the SD card slot and to insert the card, proceed as follows: 1. Extract the SD card slot cover from side of the mobile computer. Then carefully pull it out till unlocking its base as shown in the picture below: 2. Insert the card with the written part upward and push it in, aided by the back of the stylus, until it clicks into place.
DATALOGIC MEMOR™ 1 1.5 ACCESSORIES Cradles 94A151111 Datalogic Memor™ Single Cradle with spare battery slot; RS232 and USB communications Batteries 94ACC1326 Datalogic Memor™ Standard Battery Pack (Li Polymer battery pack 1000 mAh@3.7 V) + cover 94ACC1325 Datalogic Memor™ Large Capacity Battery Pack (Li Polymer battery pack 2000 mAh@3.7 V) + cover 94ACC1327 Adapter for 3 AAA Alkaline batteries + cover Power Supply 94ACC1324 PG5-30P35 AC/DC Power Supply EU/USA Plug 94ACC1334 PG5-30P35 AUS.
CONNECTIONS 2 2 CONNECTIONS 2.1 CONNECTION TO THE HOST COMPUTER 2.1.1 USB Connection You can use any standard mini USB cable to directly connect the Datalogic Memor™ to a host computer to transfer data through the USB interface. A C B Key: A Host Computer B Standard Mini USB cable C Datalogic Memor™ The Datalogic Memor™ Single Cradle can be connected to the Host by any standard mini USB cable to transfer data through the USB interface.
DATALOGIC MEMOR™ 2 2.1.2 RS232 Connection You can use a cable to directly connect the Datalogic Memor™ to a host computer to transfer data through the RS232 interface. A C B Key: A Host Computer B 94A051022 WIN-NET (HRS ST40X-18S-CV) C Datalogic Memor™ The Datalogic Memor™ Single Cradle can be connected to the Host by any standard 9-pin serial null-modem cable for RS232 communications. Once the Host has been turned on, insert the Datalogic Memor™ mobile computer into the cradle.
CONNECTIONS 2.1.3 2 WLAN Connection Datalogic Memor™ 802.11 b/g radio models can communicate with the host using the on-board radio frequency component and an Access Point connected to the host computer. A B C Key: A) Datalogic Memor™ B) Access Point C) Host – Application Server NOTE In order to avoid wasting power, the radio is off by default. If you need to have the radio working, it must be powered on using the Wireless Communications applet (see par. 3.6.4).
DATALOGIC MEMOR™ 2 2.1.4 WPAN Connections ® Bluetooth Datalogic Memor™ mobile computer models can communicate with ® a Bluetooth device, such as a printer, within a range of 10 m, using the on® board Bluetooth module. B A Key: A) Datalogic Memor™ B) Bluetooth printer NOTE 8 ® In order to avoid wasting power, the Bluetooth® module is off by default. If you need to have Bluetooth® working, the module must be powered on using the Wireless Communications applet (see par. 3.6.
CONNECTIONS 2.2 2 CONNECTION CABLES The following cable contains its order number.
DATALOGIC MEMOR™ 3 3 USE AND FUNCTIONING The use of the Datalogic Memor™ depends on the application software loaded. However there are several parameters that can be set and utilities that can be used to perform some basic functions such as data capture, communications, file management, etc. 3.1 STARTUP The Datalogic Memor™ turns on when the battery pack or the external supply is inserted. After the battery pack is installed, use the [ON/OFF] key to turn the mobile computer on and off.
USE AND FUNCTIONING 3 The mobile computer can also be awakened or turned off by the application program. NOTE 3.1.1 Using the Stylus The stylus selects items and enters information. The stylus functions like a mouse. Tap: Touch the screen once with the stylus to open items and select options. Drag: Hold the stylus on the screen and drag across the screen to select text and images. Drag in a list to select multiple items.
DATALOGIC MEMOR™ 3 3.1.2 Using the Joystick The joystick selects items and enters information. The joystick can work like the directional arrow keys of a PC keyboard or can function like a mouse and control the mouse pointer. It is possible to switch between the two functioning modes by pressing blue modifier + BKSP keys in sequence.
USE AND FUNCTIONING 3 Remove the protective film cover over the Laser Output Window before use. NOTE 3.3 DESCRIPTION OF THE KEYS The Datalogic Memor™ provides a 20-key alphanumeric keyboard + ON/OFF key + joystick. The following image shows this keyboard.
3 14 DATALOGIC MEMOR™
USE AND FUNCTIONING 3 Main Keys Function KEY FUNCTION It starts barcode data capture. The joystick lets you move forwards, backwards, upwards or downwards, scroll through a Menu list, browse among folder files or select functions if pressed down. It can work in two functioning modes: Arrow Keys Mode and Mouse Mode. It’s possible to switch between them by pressing blue modifier + BKSP keys in sequence (See par. 0).
DATALOGIC MEMOR™ 3 Special Function Icons ICON FUNCTION After a yellow modifier key press, it opens the Start menu. After a yellow modifier key press, it opens the file manager. After a yellow modifier key press, it switches ON/OFF the display backlight. After a blue modifier key press, it switches ON/OFF the keyboard backlight. After a blue modifier key press, it locks and unlocks the keyboard.
USE AND FUNCTIONING 3.4 3.4.1 3 STATUS INDICATORS LED Status The Datalogic Memor™ provides three different LEDs signaling the mobile computer status. LED STATUS Good Read and General Purpose (left side) Green It is constant for a configurable time to signal that a successful read has occurred. Green/Red It is also available to the application program. Green constant It is constant once the charging process has been completed. Red constant It is constant while charging.
DATALOGIC MEMOR™ 3 3.4.2 Taskbar The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. ICONS DESCRIPTION Time and Battery Icons It displays the time. They are representative of five different icons indicating the battery level. The icon is partially green when the power left is >20% and partially red colored when the power left is <20%. It indicates that the battery is charging.
USE AND FUNCTIONING 3.5 3 DATA CAPTURE CONFIGURATION From the Taskbar, tap the "Data Capture" icon to open a drop–down menu. Data Capture can also be accessed from the Control Panel. By selecting the Info item from this drop-down menu you can access information about the Scanner and the Software; the Configure item opens the configuration applet (Data Capture Configuration Window), while Capture accesses the data capture applet (Data Capture Window), which enables code reading.
3 DATALOGIC MEMOR™ Data Capture Configuration Window The screen format shows two columns where the left column indicates branches or parameters. Branches have three dots in the right column (...). You can navigate through the tree structure using the stylus or keyboard arrows directly on the item field or from the menu. Parameters have their corresponding current values in the right column. You can edit parameter values using the stylus or keyboard arrows directly on the item field or from the menu.
USE AND FUNCTIONING 3 Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile computer. For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD. Scan Parameters The Scan Parameters are common to all scanner modules and allow control of the scanning device.
DATALOGIC MEMOR™ 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type of scan engine mounted on the mobile computer. For a complete list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.
USE AND FUNCTIONING 3.5.2 3 Capture The Data Capture applet (Capture) enables code reading. Data Capture Window Data Capture can also be enabled through the Configuration applet by selecting File ->Scanner from the main menu, or by enabling the parameter Scan Always On in the Scan Parameters branch.
DATALOGIC MEMOR™ 3 3.6 CONTROL PANEL From the Desktop, double tap on the "Control Panel" icon to open the Windows CE 5.0 control panel main window. The Control Panel can also be launched from Start ->Settings ->Control Panel. APPLET programs are displayed as icons; one icon corresponds to each APPLET. Control Panel 3.6.1 Buttons The BUTTONS Applet allows assigning desired applications to be launched by one of the function keys (F1...F4).
USE AND FUNCTIONING 3.6.2 3 Registry The REGISTRY ADMIN applet provides management of Windows CE 5.0 registry. Select the REGISTRY ADMIN applet by double tapping the Registry Admin icon. The Registry Administration Main window appears. Two functions are available: - Save Registry allows permanently saving the Windows configuration (example: custom configuration of screen desktop background color, or network adapter configuration) to non-volatile memory (SAVE button).
DATALOGIC MEMOR™ 3 3.6.3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the System Folder. Two functions are available on the Files Admin Main window by means of two buttons: Files Admin Main Window Save Session: with this button all files will be permanently saved in the \Windows directory in non-volatile memory.
USE AND FUNCTIONING 3 Safe Setup First Mask Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new files and directories present in the \Windows directory, and will copy them to the \Backup\Windows directory. At the next hardware reset, these files will be restored (see par. 3.8). - Simply skip the first mask either by closing it or by pressing the ESC key.
DATALOGIC MEMOR™ 3 3.6.4 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the ® 802.11 b/g radio and of the Bluetooth module. Select the WIRELESS COMMUNICATIONS applet by double tapping the Wireless Communications icon. The following window will appear: Wireless Communications Window In order to avoid wasting power, all modules are off by default. NOTE Wireless performance may vary according to environmental conditions and infrastructure settings.
USE AND FUNCTIONING 3.7 3 WINDOWS CONNECTIONS To connect the Datalogic Memor™ to another device (i.e. Host PC) from Windows, several programs are available in the "Connections" folder on the Datalogic Memor™ Desktop. These programs require specific electrical connections in order to function properly. From the Desktop, double tap on the "Connections" folder to open the following window: Windows Connections 3.7.
DATALOGIC MEMOR™ 3 ® By default, ActiveSync does not automatically synchronize ® all types of information. Use ActiveSync options to turn synchronization on and off for specific information types. NOTE For example: Synchronize Microsoft Word and Microsoft Excel files between the Datalogic Memor™ and the desktop computer. The files will automatically be converted to the correct format. Visit the following Microsoft Web site for the latest in updates and technical information: http://www.microsoft.
USE AND FUNCTIONING 3. 3 Tap on the “Me” button to enter the related window; then, tap on the “ON” ® button to activate the Bluetooth module. The module activation may be also performed by using the WIRELESS COMMUNICATION applet as described in par. 3.6.4. By tapping on the “HW Details” and “SW Details” buttons, information ® about the mobile computer Bluetooth hardware and software will be displayed, while the “Enable Encryption” button starts encryption of the ® Bluetooth communication data.
DATALOGIC MEMOR™ 3 ® The “Serial Port” button starts communication through the Bluetooth serial port COM 5 (typically used for connection with GPS devices). The “Printer” button starts communication with a printer through the ® Bluetooth serial port COM 5. The “Kbd Emulation” button allows connection with a barcode reader using the keyboard emulation. The “ActiveSync” button starts communication with a PC equipped with a ® Bluetooth antenna and the related ActiveSync. 6.
USE AND FUNCTIONING 3 "DebugOutputChannels"=dword:00000002 "IdleTimeout"=dword:0000012c "AllowAnonymous"=dword:00000001 "AllowAnonymousVroots"=dword:00000001 ® 2. Copy this file to the Datalogic Memor™ using ActiveSync . 3. Launch the .reg file from the Datalogic Memor™. 4. Perform a software reset on the Datalogic Memor™. 5. From the PC > Explorer address bar (or running an FTP Client from the PC), enter the Datalogic Memor™ IP address.
DATALOGIC MEMOR™ 4 4 MAINTENANCE Rechargeable backup batteries and battery packs are not initially charged. Therefore the initial operation to perform is to charge them. See below. NOTE CAUTION 4.1 By default, the backup battery is disconnected at the factory to avoid damage due to excessive draining. If it is not connected (through the backup battery switch) and subsequently charged together with the battery pack, all data will be lost when changing the battery pack.
MAINTENANCE 4 Be careful when using sharp-edged tools to move the switch from the “disconnected” position to the "connected" position and vice versa! CAUTION 4.2 CHARGING THE BATTERY PACK The battery pack autonomy varies according to factors, such as the frequency of barcode scanning, RF usage, etc. The battery icon on the Taskbar indicates when the battery pack is low. It is possible to recharge the battery pack by connecting the power supply directly to the Datalogic Memor™.
DATALOGIC MEMOR™ 4 4.3 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Datalogic Memor™. 2. Use the back of the stylus to rotate the battery cover screw to the vertical position, then push the battery clips in, as indicated in the figure below. The battery pack cover is now released. 3. Remove the cover and then the battery pack.
MAINTENANCE 4 4. Install the new battery pack, first insert the bottom (contacts) side, then the upper (lock) side as indicated in the following figure: 5. For correct locking, push the battery clips outwards and rotate the screw to the horizontal position. WARNING NOTE Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type.
DATALOGIC MEMOR™ 5 5 5.1 TECHNICAL FEATURES TECHNICAL DATA Datalogic Memor™ Common Features Electrical Features Power DC Supply Battery Pack 5 V ± 5% 1 cell Li Polymer 1000 mAh@3.
TECHNICAL FEATURES Programming Features Operating system Laser Models Decoded barcodes 1D 5 Windows CE 5.0 UPC A, UPC E, EAN 8, EAN 13, Code 39, Code 39 Full ASCII, Code 32, Interleaved 2 of 5, Industrial 2 of 5, Matrix 2 of 5, Code 128, EAN 128, Codabar, MSI, Plessey, Code 93, Code 11 Datalogic Memor™ Laser Optical Features Laser Optical Features Maximum resolution Skew angle Pitch angle Scan rate - bidirectional Light source laser scanner Safety class Datalogic Memor™ XXX 9XX XXX Models 0.
DATALOGIC MEMOR™ 6 6 TEST CODES High Density Codes 0.
TEST CODES 6 Medium Density Codes 0.
DATALOGIC MEMOR™ 6 Low Density Codes 0.
GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile units. Hand-held mobile computers, PDAs or other devices equipped with radio cards, communicate with wired networks using Access Points (AP). The mobile unit (mobile computer) may roam among the APs in the same subnet while maintaining a continuous, seamless connection to the wired network.
Host A computer that serves other mobile computers in a network, providing services such as network control, database access, special programs, supervisory programs, or programming languages. Liquid Crystal Display (LCD) A display that uses liquid crystal sealed between two glass plates. The crystals are excited by precise electrical charges, causing them to reflect light outside according to their bias. They use little electricity and react relatively quickly.
INDEX A Accessories; 4 ActiveSync® Remote; 30 H Hardware and Software Reset; 16 L B Backup Directory File Management; 33 Bluetooth® Manager Device Setup; 30 Buttons; 24 Laser Safety; ix M Maintenance; 35 Microsoft® ActiveSync®; 29 Model Description; 1 C Charging the Batteries; 36 Cleaning the Mobile Computer; 38 Connecting the Backup Battery; 35 Connection Cables; 9 RS232 Direct Connection; 9 Connections; 5 Control Panel; 24 Conventions; vii D Data Capture; 12 Laser Data Capture; 12 Data Capture Configu
Using the Joystick; 12 Using the Stylus; 11 W WEEE Compliance; xiii 46 Windows Connections; 29 Wireless Communications; 28 WLAN Connection; 7 WPAN Connections; 8
Datalogic Mobile S.r.l. Via S.