User's Manual Addendum

DL-Memor™ Regulatory Addendum
RF EXPOSURE INFORMATION (SAR)
This model device meets the government’s requirements for
exposure to radio waves. This device is designed and
manufactured not to exceed the emission limits for exposure
to radio frequency (RF) energy set by the Federal
Communications Commission of the U.S. Government.
The exposure standard for wireless devices employs a unit of
measurement known as the Specific Absorption Rate, or SAR.
The SAR limit set by the FCC is 1.6W/kg. *Tests for SAR are
conducted using standard operating positions accepted by the
FCC with the device transmitting at its highest certified power
level in all tested frequency bands. Although the SAR is
determined at the highest certified power level, the actual SAR
level of the device while operating can be well below the
maximum value. This is because the device is designed to
operate at multiple power levels so as to use only the poser
required to reach the network. In general, the closer you are to
a wireless base station antenna, the lower the power output.
The highest SAR value for the model device as reported to the
FCC are the following:
DL-Memor + 802.11g + BT models: for use at the head is
0.029 W/kg and when worn on the body, as described in
the user guide, is 0.00412 W/kg. (Body-worm
measurements differ among device models, depending
upon available enhancements and FCC requirements);
DL-Memor + EdgeA + BT models: for use at the head is
1 W/kg (GSM 850 Band) and 1.08 W/kg (GSM 1900
Band). When worn on the body, as described in the user
guide, is 0.79W/kg (GSM 850 Band) and 0.198W/kg
(GSM 1900 Band). (Body-worm measurements differ
among device models, depending upon available
enhancements and FCC requirements).
While there may be differences between the SAR levels of
various devices and at various positions, they all meet the
government requirement.
852000500
The FCC has granted an Equipment Authorization for this
model device with all reported SAR levels evaluated as in
compliance with the FCC RF exposure guidelines. SAR
information on this model device is on file with the FCC and
can be found under the Display Grant section of
http://www.fcc.gov/oet/fccid after searching on the below FCC
IDs:
FCC ID: U4G0030 for DL-Memor+802.11g+BT models;
FCC ID: U4G0033 for DL-Memor+EdgeA+BT models.
This device is compliant with SAR for general population
/uncontrolled exposure limits in ANSI/IEEE C95.1-1999 and had
been tested in accordance with the measurement methods and
procedures specified in OET Bulletin 65 Supplement C.
For body worn operation, this device has been tested and meets
the FCC RF exposure guidelines for use with an accessory that
contains no metal and the positions the handset a minimum of
1.5 cm from the body. Use of other enhancements may not
ensure compliance with FCC RF exposure guidelines.
If you do not use a body-worn accessory and are not holding the
device at the ear, position the handset a minimum of 1.5 cm from
your body when the device is switched on.
INDUSTRY CANADA COMPLIANCE
Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES-
003. Cet appareil numérique de la classe B est conforme à la
norme NMB-003 du Canada.
This device and its antenna(s) must not be co-located or
operating in conjunction with any other antenna or transmitter.
The County Code Selection feature is disabled for products
marketed in the US/Canada.
IMPORTANT NOTE:
IC Radiation Exposure Statement
This EUT is compliant with SAR for general
population/uncontrolled exposure limits in IC RSS-102 and had
been tested in accordance with the measurement methods and
procedures specified in IEEE 1528. This equipment should be
installed and operated with minimum distance 1,5cm between
the radiator & your body.
CTIA COMPLIANCE
Do not disassemble or open crush, bend or deform,
puncture or shred.
Do not modify or remanufacture, attempt to insert foreign
objects into the battery, immerse or expose to water or
other liquids, expose to fire, explosion or other hazard.
Only use the battery for the system for which it is specified.
Only use the battery with a charging system that has been
qualified with the system per this standard. Use of an
unqualified battery or charger may present a risk of fire,
explosion, leakage, or other hazard.
Do not short circuit a battery or allow metallic conductive
objects to contact battery terminals.
Replace the battery only with another battery that has been
qualified with the system per this standard, IEEE-Std-1725-
2006. Use of an unqualified battery may present a risk of
fire, explosion, leakage or other hazard.
Promptly dispose of used batteries in accordance with local
regulations.
Battery usage by children should be supervised.
Avoid dropping the phone or battery. If the phone or battery
is dropped, especially on a hard surface, and the user
suspects damage, take it to a service center for inspection.
Improper battery use may result in a fire, explosion or other
hazard.
The device shall only be connected to products that bear
the USB-IF logo or have completed the USB-IF compliance
program.
only applicable to EdgeA + Bluetooth® models