1 5
Humidity: 90% non condensing
Cabinet
The cabinet must not have any exposed sharp edges, which could represent a
danger to customers.
The requirements for air passages to cool both the JoyaCradle Dispensers and
the power supplies must be adhered to in order to avoid overheating problems
for the components inside the cabinet.
All components having dangerous voltage levels must be protected from
unauthorized access. Only qualified personnel should be authorized access for
maintenance purposes.
In particular, the opening at the top of the cabinet must be closed with a grill or
mesh that prevents access from the outside to the power supplies below. In
addition, the plastic protection covers must be mounted over the power supply
terminals to avoid accidental contact by maintenance personnel when the
cabinet is open.
Wiring
The wires used for cabling must have flame retardant insulation.
The cables must be affixed to the cabinet avoiding types of cable clamps that
use screws or have moving parts that press directly upon the cable itself. Cable
clamps must also be applied close to the wires coming from the power supplies
so that they won't be accidentally pulled out of the power supply terminals to
which they are connected.
Avoid running cables with sharp bends or that rest on sharp edges which can
damage them over time and in the long run pose a danger inside the cabinet.
After making all the wiring connections, if some connections have wire exposed
without insulation, they must be insulated.
5.3.11 Connection to AC Line Voltage
If connection to the AC power line is made with a plug at the end of the cable,
The outlet to which it is inserted must be close by and easily accessible. The
outlet must also be rated for the maximum power consumption, which can be
considered equal to the nominal power of the connected power supplies.
If the Terminal Distributor is connected in a fixed electrical plant, a circuit
breaker must be provided in order to completely disconnect the AC line voltage
form the Cradle Dispenser cabinet. This circuit breaker must be positioned
close to the cabinet and be easily accessible. It must also be rated for the
maximum power consumption and must meet the Safety Normatives currently in
force.