User's Manual

DECODING PARAMETERS
This section contains information about programmable settings for the Lynx™. Use
the Lynx™ Management Utility (FMU), the Scanner Control Panel applet, the
Imaging Control Panel applets to program the Lynx™.
It provides the following information:
Code Parameter is the “human” name for the programming option.
I.D. # is the “decoder” name for the programming option. For example, to set a
Code 39 minimum label length, use I.D. 0120. Programming I.D. numbers given
in this appendix can be used with all programming methods. Note that the
Programming I.D. numbers are provided in hexadecimal notation.
Type tells what kind of setting to use for each code parameter.
On/Off is a toggle. 1 turns the parameter on, and 0 turns it off.
Acceptable Input gives the settings or range of settings for each code
parameter.
Defaults indicates how the parameter is set when the predefined default FF39,
FF3A, or FF3B is selected.
Minimum (FF39) turns every on/off parameter off and sets all minimum and
Maximum Label Lengths to the lowest values.
Maximum (FF3A) turns every on/off parameter on, sets all Minimum Label
Lengths to the lowest values, and sets all Maximum Label Lengths to the highest
values. Use this default for troubleshooting; it provides the best settings for
reading an unknown code symbology and can identify the symbology of scanned
bar codes.
Factory (FF3B) is the factory setting installed on the Lynx™. This default set will
work for most applications. To reset the Lynx™ the original defaults, scan the
Factory bar code
Scanner Type shows, with a checkmark, which modules support the
specified parameter.