PROGRAMMING CODES WITHOUT PARAMETERS
The following table describes the functions of special bar codes that take no
parameters:
Code
Parameter
I.D. # Function
Defaults
Minimum
FF39
Turns every On/Off parameter off and sets all minimum and
Maximum Label Lengths to the lowest values.
Defaults
Maximum
FF3A
Turns every On/Off parameter on and sets all minimum and
Maximum Label Lengths to the highest values. This default set is
normally used only for troubleshooting. It gives the best chance of
reading an unknown bar code symbology and also identifies the
symbology of each bar code scanned.
Defaults
Factory
FF3B
This is the default parameter settings that was installed at the
factory. This default set will work for most applications.
Defaults
Registry
FF3C
This restores all parameter settings to the values that exist in the
registry. This is useful for restoring parameters to a known working
set of values which have been saved using code parameter FF3F.
Exit and
Restore
FF3D
Stops a label programming sequence and restores all parameter
settings to the values that exist in the registry.
Exit and
Save
FF3E
Stops a label programming sequence. The last valid parameter
settings are left intact.
Exit and
Commit
FF3F
Stops a label programming sequence and writes all parameter
settings into the registry. This can be used to save a customized
set of parameter settings for restoring later via parameter FF3C.