BAR CODE PARAMETERS
The following table lists the standard customer programmable settings for the
Lynx™:
Codabar
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the
Codabar symbology.
0300 On or Off Off On On
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0301 On or Off Off On Off
Enable
Checksum
Requires the use of
checksum characters to
verify a bar code.
0302 On or Off Off Off Off
Send
Checksum
Instructs the terminal to
include the checksum in
the label transmission.
0303 On or Off Off Off Off
Send Start/
Stop
Instructs the decoder to
transmit the decoded start
and stop characters of
Codabar labels. The start
and stop characters will
both be translated as A, B,
C, or D.
0305 On or Off Off On Off
Convert to
CLSI
Restricts the Codabar
decoder to only read
labels that conforms to
CLSI specifications. Label
length must be 14, and the
data is split into fields of 1,
4, 5, and 4 characters
separated by spaces.
0306 On or Off Off Off Off
Allow Wide
Intercharacter
Gaps
Allows wide gaps to
appear between
characters in a label.
0307 On or Off Off On On
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0320 01 - 50 01 01 04