Trioptic
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the
Trioptic symbology
.
0108 On or Off
Off On Off
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0109 On or Off Off On Off
Read
Verification
Sets the number of times a
label must be read before
it is transmitted.
0124 01 - 04
01 02 01
User ID
Specifies the symbology
identifier (if any) that is
sent when parameter
Send Code ID (Index
0025) is set to 3. ASCII
code zero (null) is used to
indicate that an identifier is
not to be sent for the
symbology.
0125
Any
single
ASCII
character
(00 = Off)
‘X’ ‘X’ ‘X’