User's Manual

Code 93
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the Code
93 symbology.
0400 On or Off Off On Off
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0401 On or Off Off On Off
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0420 01 - 50 01 01 02
Maximum
Label
Length
This feature specifies the
maximum allowable length
of a Code 93 label.
The length includes check
and data characters.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0421 01 - 50 01 50 20
Read
Verification
Sets the number of times a
label must be read before
it is transmitted.
0422 01 - 04 01 02 01
User ID
Specifies the symbology
identifier (if any) that is
sent when parameter
Send Code ID (Index
0025) is set to 3. ASCII
code zero (null) is used to
indicate that an identifier is
not to be sent for the
symbology.
0423
Any
single
ASCII
character
(00 = Off)
‘L’ ‘L’ ‘L’