Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the
Standard 2 of 5 symbology.
0200 On or Off Off On Off
Enable
Aggressive
Decoding
Enables more aggressive
decoding algorithms to be
used in order to scan hard
to read labels.
0201 On or Off Off On Off
Enable
Checksum
Requires the use of
checksum characters to
verify a bar code.
0202 On or Off Off Off Off
Send
Checksum
Instructs the terminal to
include the checksum in
the label transmission.
0203 On or Off Off Off Off
Use 2-bar
Start/Stop
Allows the terminal to
recognize labels that are
printed using only two bars
for start/stop characters.
0204 On or Off Off Off Off
Minimum
Label
Length
Set the minimum label
length to be less than or
equal to maximum label
length.
0220 01 - 50 01 01 06
Maximum
Label
Length
This feature specifies the
maximum allowable length
of a Standard 2 of 5 label.
The length includes check
and data characters.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0221 01 - 50 01 50 10
Read
Verification
Sets the number of times a
label must be read before
it is transmitted.
0222 01 - 04 01 02 01
User ID
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is
set to 3. ASCII code zero
(null) is used to indicate
that an identifier is not to
be sent for the symbology.
0223
Any
single
ASCII
character
(00 = Off)
‘F’ ‘F’ ‘F’