User's Manual

GS1 DataBar Expanded
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults Scanner Type
Min
Max
Factory
Laser
2D Imager
Lorax
Enter 1 for On and 0 for Off
Enable
Enables/disables the GS1
DataBar Expanded
symbology.
0810 On or Off Off On On
Convert to
UCC-EAN 128
Instructs the decoder to
transmit the label data as
one or more UCC-128
labels. The transmission
will use the UCC-128 AIM
identifier.
0814 On or Off Off On Off
Minimum
Sets the minimum bar
code label length to be
less than or equal to
maximum label length.
0824 1 - 74 01 74 01
Maximum
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0825 1 - 74 01 74 74
User Code ID
Specifies the symbology
identifier (if any) that is
sent when parameter Send
Code ID (Index 0025) is
set to 3. ASCII code zero
(null) is used to indicate
that an identifier is not to
be sent for the symbology.
0827
Any
single
ASCII
character
(00 = Off)
‘R’ ‘R’ ‘R’