User's Manual

QR Code
Code
Parameter
Description
I.D.#
Accept.
Input
Defaults
Scanner
Type
Min
Max
Factory
2D Imager
Enter 1 for On and 0 for Off
QR Code
Enable
Enables/disables QR Code
symbology.
0B10 On or Off Off On Off
QR Code
Minimum
Set the minimum bar code
label length to be less
than or equal to maximum
label length.
0B28 1 - 3500 1 3500 1
QR Code
Maximum
This feature specifies the
maximum allowable length
of a label. The length
includes check and data
characters, if applicable.
Maximum Label Length
should be greater than or
equal to Minimum Label
Length.
0B29 1 - 3500 1 3500 3500
QR Code
User ID
Specifies the symbology
identifier (if any) that is
sent when parameter
Send Code ID (Index
0025) is set to 3. ASCII
code zero (null) is used to
indicate that an identifier
is not to be sent for the
symbology.
0B2B
Any
single
ASCII
character
(00 = Off)
‘c’ ‘c’ ‘c’
Micro QR Code
Enable
Enables/disables Micro
QR Code symbology.
0B14 On or Off Off On Off