Technical information

96 Operations AccuLazr™ AL5010 Product Line Manual
NETWORK LED during Normal Operations
Mode Description
Single TCP/IP Solid GREEN – AL5010 connected to a host.
NOTE: If both Host 1 and Host 2 are used, the LED will be
solid GREEN if either port is connected.
Off – No host connection.
NOTE: If UDP messaging is used (unconnected messages)
the Network LED will be off.
EtherNet/IP Solid GREEN – AL5010 made a connection to the PLC
Flashing GREEN – No connection made with the network
Flashing RED – Lost network connection
Controller/Client Controller
Solid GREEN – The correct number of client(s) with the
same group number have been found.
Flashing RED – All the client(s) with the same group
number have NOT been found
Client
Solid GREEN – Connected to a controller with the same
group number.
Off – Not connected to a controller with the same group
number.
NOTE: The mode indicated by the Network LED is dependent on the AL5010
configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode
operation is the lowest.
Using Control Panel Buttons to Check Normal Operations
Ref Button Description
Restore to Scan
Head
Restores parameters from Mounting base to Scan
Head
Button must be pressed twice to initiate action.
See page 99 for procedure.
Backup to
Mounting Base
Downloads parameters from Scan Head to Mounting
base
Button must be pressed twice to initiate action.
See page 99 for procedure.
Test /Diagnostic
(Laser Shutoff)
Enables the AL5010 test mode.
(Test mode can also be selected remotely using
Tools > Commands > Test Mode.)
Use to perform laser shutoff. (See page 107.)
REMEMBER: AL5010’s control panel buttons can be enabled / disabled
through the use of the browser-based setup application.
(See Modify > AL5010 Configuration, Enable AL5010 Control Panel
Buttons.)
Accu-Sort Systems, Inc. 06-AL5010_Operations_R20.doc