Technical information

AccuLazrâ„¢ AL5010 Product Line Manual Operations 99
Backup / Restore Procedures
To backup parameters from scan head to mounting base:
1. Press the backup button for about 1 second.
2. Release button. The bar graph LEDs continuously flash to indicate the
button has been pressed long enough. If the LEDs flash only once, the
button was not pressed long enough.
3. Press button a second time while LEDs are flashing. Hold for about 1
second.
4. Release button. The bar graph LEDs strobe from 5 to 1 indicating
parameters are being backed up from scan head to mounting base.
5. When the LEDs stop strobing, the backup is complete.
To restore parameters from mounting base to scan head:
NOTE: The restore parameters function can cause the
scanner to reboot.
1. Press the restore button for about 1 second.
2. Release button. The bar graph LEDs continuously flash to indicate the
button has been pressed long enough. If the LEDs flash only once, the
button was not pressed long enough.
3. Press button a second time while LEDs are flashing. Hold for about 1
second.
4. Release button. The bar graph LEDs strobe from 1 to 5 indicating
parameters are being uploaded from mounting base to scan head.
5. When the LEDs stop strobing, the upload is complete.
Button and LEDs involved with Backup / Restore
Restore
Backup
06-AL5010_Operations_R20.doc Accu-Sort Systems, Inc.