Technical information

108 Maintenance AccuLazr™ AL5010 Product Line Manual
Maintenance Tasks
Perform the maintenance tasks on an “as needed” basis to assure proper
operation of the AL5010. Task schedule frequency depends upon the
application environment conditions. It only requires a few minutes to
complete each maintenance task.
Exterior Cleaning
WARNING: Shut down the reader before performing this maintenance
task. Do not stare into the reader’s exit window at the laser light. Avoid
direct eye exposure. The laser light level does not constitute a health
hazard, however staring at the laser light for prolonged periods could result
in eye damage.
WARNING: There are no user serviceable parts inside the AL5010. No
internal components of the AL5010 are field replaceable units (FRUs).
Opening the unit will potentially expose the user to emitted laser radiation,
high voltage, and could reduce the effectiveness of the device’s IP rating.
DO NOT REMOVE the faceplate from the scan head enclosure. Opening
the AL5010 will also void the factory warranty.
CAUTION: CLASS 3R LASER RADIATION. WHEN OPEN AVOID
DIRECT EYE EXPOSURE. See warning above.
CAUTION: Do not use any chemical on the reader that is unsafe for
plastics, such as benzene, acetone, or similar products. Before performing
this maintenance task, be sure to shutdown the reader.
The exterior cleaning procedure may be performed without removing the
reader from the mounting structure.
1. Turn off the reader’s lasers.
2. Clean the exterior (except the exit window) with a clean, soft-bristle
brush. Be sure not to brush any dust, dirt, or debris onto the exit window.
3. Carefully remove any debris in or around the exit window.
4. Wipe the exterior (except the exit window) with a clean, soft cloth
dampened slightly with a mild detergent solution.
5. The exit window should be cleaned after this task is completed.
Accu-Sort Systems, Inc. 07-AL5010_Maintenance_R20.doc