Technical information

AccuLazr™ AL5010 Product Line Manual Troubleshooting 115
Control Panel LED Fault Detect Descriptions
LED Description
STATUS RED indicates a problem regarding the overall "health" of the
reader.
TRIGGER
Indicates the trigger input.
The LED is controlled through software no matter the trigger
source (including software trigger).
READ RED identifies a No Read condition.
Check bar code print quality, trigger configuration, and bar code
parameters.
RX/TX
If bar codes are being read, but the LED is NOT illuminated, data
is not being transmitted on serial port 1.
NETWORK
(See Network LED – Fault Detection.)
LINK
If the LED is not flashing, there is no network connection.
Bar Graph
(LED 1 – 5)
(Laser Shutoff)
Read quality indicator (5 = Good, 1 = Poor).
5 = 81-100%
4 = 61-80%
3 = 41-60%
2 = 21-40%
1 = 00-20%
NOTES: Also flashes during parameter upload/backup.
LEDs stay on when Test/Diagnostic button C is pressed during
the laser shutoff procedure.
08-AL5010_Troubleshooting_R20.doc Accu-Sort Systems, Inc.