Technical information

116 Troubleshooting AccuLazr™ AL5010 Product Line Manual
NETWORK LED – Fault Detection Only
Mode Description
Single TCP/IP
LED is Off – No host connection or UDP messaging is used.
NOTE: If UDP messaging is used (unconnected messages)
the Network LED will be off.
EtherNet/IP Flashing GREEN – No connection made with the network
Flashing RED – Lost network connection
Controller/Client Controller
Flashing RED – All the client(s) with the same group
number have NOT been found or a client’s tracking does
not match the controller.
Client
Off – Not connected to a controller with the same group
number. Match the client to the controller’s group number.
Solid RED – Client’s tracking does not match the controller.
NOTE: The mode indicated by the Network LED is dependent on the AL5010
configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode
operation is the lowest.
NOTE: See Network LED during Normal Operations.
Control Panel Buttons – Uses during Troubleshooting
Ref. Button Description
Restore to Scan
Head
Use to restore a set of parameters from the wiring
base to a replacement scan head.
NOTE: This only works if the Backup to Base button
has been used earlier to assure the correct parameters
are stored in the wiring base.
Backup to Base
When it becomes necessary to replace a scan head,
be sure to use this button to download a backup set of
parameters from the scan head to the wiring base. By
doing this, it is easy to configure your replacement
scan head by using the Upload to AL5010 button.
Test /Diagnostic
(Laser Shutoff)
Enables the AL5010 test mode.
(Test mode can also be selected remotely using
Tools > Commands > Test Mode On.)
Use to perform laser shutoff.
NOTE: Keep in mind that the buttons on the reader’s control panel can be
enabled/disabled through the use of the AccuLazr user interface.
(For details, see Chapter 5.)
Accu-Sort Systems, Inc. 08-AL5010_Troubleshooting_R20.doc