Technical information

AccuLazr™ AL5010 Product Line Manual Appendix A: Specifications 135
Power Supply for AL5010
Characteristic Description
Dimensions L 4.65” [118 mm] x W 1.36” [34.5 mm] x H 2.05” [52 mm]
Weight 0.6 lbs. [0.275 kg]
Temperature Operating: 0° to +70° C
Storage: -40° to +85° C
Relative Humidity 5-95% non-condensing
Enclosure ABS plastic, Rated for IP40
Power Requirements Input: 90-264 VAC / 0.5A typical, 1.0A max. @ 120 VAC
Output: Max. 250mA Load
Power Consumption < 40 W
Connections Male IEC (available with either domestic or international power cord)
Compliance UL, cUL, CE, FCC (Class A) (See Compliance table.)
Output Modules
Part Number 1000056136 1000056137
Maximum Line Voltage 60 VDC 42 VAC
Minimum Line Voltage 3.0 VDC 12 VAC
Maximum Peak Off State Voltage 60 VDC 42 VAC peak
Maximum Peak Off State Leakage 1.0 mA 2.5 mA RMS
Static off–state dv/dt -- 200 V/usec
Maximum On–State Current 0.5 A DC 0.5 A RMS
Minimum On–State Current 10 mA DC 50mA RMS
Maximum 1 Cycle Surge -- 4 A peak
Maximum 1 Second Surge 1.5 A DC --
Peak On–State Voltage 1.5 V DC 1.6 V peak
*NOTE: Relay modules are only for connection to SELV, LPS power source and shall also meet
the requirements for Class 2.
Input Module
Part Number 1000056135 *
Maximum Input Voltage 32 VDC
Minimum Input Voltage 3.3 VDC
Input Resistance 1 k ohm
Maximum Input Current 32mA DC@ 32 VDC
Drop Out Current 1.0 mA DC
Allowable Off–State Input Current 1.0 mA DC
Allowable Off–State Input Voltage 2.0 VDC
* NOTE: Compatible with TTL level voltages.
A1-AL5010_Specifications_R2.doc Accu-Sort Systems, Inc.