Technical information

168 Appendix C: AccuLazr User Interface AccuLazr
AL5010 Product Line Manual
Modify Settings > Network (Message
Definition Tab)
Selection Definition
Header - Character string specified for the header. Sent at
beginning of every message.
Trailer - Character string specified for the trailer. Use to
terminate every message.
Sequence - When enabled, a sequence number consisting of
the specified number of digits is inserted just after the header.
Check Digits - When enabled, a two-character hexadecimal
check character is inserted just prior to the trailer.
Include All Bar Codes In One Message (checkbox) - Affects
how the reader handles multiple bar code transmissions. If
enabled, the bar codes are sent in one message (between one
header and trailer) and each bar code is separated by the
specified “separator.” If disabled, all bar codes are always sent
as a complete message (with a header and trailer).
Bar Code Separator - String used to separate multiple bar
codes (see above).
Network 1
Framing
Power Up Message - String that is always sent on reader
initialization. Note that for a Network connection, this string is
always sent when the socket connection is made.
Read – Select None, Send Bar Code, or User Defined from
the drop-down list.
None: Nothing is sent for a valid read.
Send Bar Code: The bar code is sent.
User Defined: A user specified message.
Network 1
Messages
No Read – Select None, Repeat Character, or User Defined
from the drop-down list.
Accu-Sort Systems, Inc. A3-AL5010_User Interface_R20.doc