Technical information

172 Appendix C: AccuLazr User Interface AccuLazr
AL5010 Product Line Manual
Modify Settings > Relay
I/O 1 Configuration = Used as input
Selection Definition
Custom Input
Select this for use with applications involving custom software
to select a customized input option.
Learn Match
Code
When this input is selected, the AL5010 is placed into Test
Mode in order to "learn" a match code. When the line is
deactivated, Test Mode is exited. When this option is enabled,
the last code read is stored in the first entry of the Match Table.
End Trigger
Active as end of trigger signal.
NOTE: Available only at I/O#1 if the Trigger Source is set to
Hardware Start/End Trigger.
Height Tracking
Photoeye
Used for applications that require Height Tracking Photoeyes.
Up to three photoeyes may be used to divide the reader's depth
of field into up to four zones. The Distance from reader (in
inches) must also be set.
If an error message is displayed when saving or retrieving
parameters, be sure that the proper dimensions are entered in
the Reader Mounting (near/far) and I/O Configuration (distance
from scanner).
For installation details, reference the AL5010 Product Manual,
Chapter 3, Mounting the Height Tracking Photoeyes.
Active Low/
Active High
Select Active Low or Active High from the drop-down list.
Active Low: The trigger is active when the input signal is
low.
Active High: The trigger is active when the input signal is
high.
Accu-Sort Systems, Inc. A3-AL5010_User Interface_R20.doc