Technical information

AccuLazr™ AL5010 Product Line Manual Appendix D: Networking Guide 205
Discrete Output Data Object (72
HEX
– 1 Instance)
Class Attributes
Attribute ID Name Data Type Data Value
Access
Rule
1 Revision UINT 1 Get
Instance Attributes
Attribute ID Name Data Type Default
Data Value
Access
Rule
3 Discrete Output Data UINT 0 Get / Set
Discrete Output Word
Bit Bit = 0 Bit = 1
0* Trigger Off Trigger On
1 – 7 Unused Unused
8* AL5010 Relay #1 Off AL5010 Relay #1 On
9* AL5010 Relay #2 Off AL5010 Relay #2 On
10* AL5010 Relay #3 Off AL5010 Relay #3 On
11* AL5010 Relay #4 Off AL5010 Relay #4 On
12-15 Unused Unused
* If enabled on AL5010
Common Services
Implemented for Service Code
Class Level Instance Level
Service Name
0E
HEX
Yes Yes Get_Attribute_Single
10
HEX
No Yes Set_Attribute_Single
A4-AL5010_Networking_Guide_R20.doc Accu-Sort Systems, Inc.