Technical information

38 Electrical Installation AccuLazr™ AL5010 Product Line Manual
Installation Sequence(s)
NOTE: Everything should be MECHANICALLY INSTALLED before
performing any ELECTRICAL INSTALLATION. See Chapter 3 for
mechanical installation details.
Installing a Single Unit
To install a single unit, follow this sequence of steps:
Complete mechanical installation.
See Chapter 3.
Complete electrical installation.
Ground the mounting structure to protective earth (PE) ground.
Connect AL5010 reader to interface module (two connections).
Connect Ethernet network to interface module.
Connect the power supply to interface module.
Connect trigger to interface module.
Connect tachometer to interface module (Enhanced Interface
Module Only).
Connect serial communications to interface module.
Connect wiring for I/O module(s) to interface module (Enhanced
Interface Module Only).
Install Fieldbus if needed- DeviceNet or Profibus (Enhanced
Interface Module Only).
Attach scan head to mounting base.
NOTE: To reduce the possibility of damage to the scan head, install it after
the interface module is mounted, wired, and all wiring is checked for
accuracy. Be sure to perform the polarity check before attaching the scan
head.
Setup your AL5010.
See Chapter 5.
Check operations.
See Chapter 6.
Accu-Sort Systems, Inc. 04-AL5010_Electrical_Installation_R20.doc