Technical information

46 Electrical Installation AccuLazr™ AL5010 Product Line Manual
Power Requirements
IMPORTANT: When planning your installation wiring, remember all power
connections must be quick-disconnect. For PERMANENTLY CONNECTED
EQUIPMENT (i.e., AL5010 using DC power) a readily accessible
disconnect device must be incorporated in the building installation wiring.
For PLUGGABLE EQUIPMENT (i.e., AL5010 using AC power supply with
non-detachable power cord), the socket-outlet must be installed near the
equipment and must be easily accessible.
Power Supply Connections
CAUTION: Follow all safety procedures regarding high-voltage as outlined
in Chapter 2, Safety. No power should be applied to any device until all
wiring is completed and checked for accuracy.
REMEMBER: The socket-outlet must be installed near the AL5010’s
power supply. The outlet must be a readily accessible disconnect device.
Using Accu-Sort Power Supplies
Single Reader The AL5010 reader requires 25 watts (maximum) of power.
The Accu-Sort power supplies are IP54 rated for industrial environments.
The supply includes a power cord for either 125V or 230V applications.
1. Locate the POWER terminal blocks on the interface module.
2. Connect the power supply wiring to the terminal blocks as shown below.
3. Make sure wiring cannot come loose from the terminal blocks.
4. Properly tighten the cord grips.
Multiple Readers When a multiple reader application uses Accu-Sort power
supplies, each AL5010 is powered by a separate power supply. DO NOT
connect power supplies in parallel. (See drawing in Appendix F.)
Power Connections Using Other Power Supplies
IMPORTANT: All non Accu-Sort power supplies, whether for single or
multiple reader applications, must be an LPS or Class 2 power supply. The
supply must provide 25 watts (10-28 VDC) of power to each AL5010.
Accu-Sort Systems, Inc. 04-AL5010_Electrical_Installation_R20.doc