Technical information

AccuLazrâ„¢ AL5010 Product Line Manual Electrical Installation 51
I/O Module Connections
The Enhanced Interface Module supports up to four (4) optional input or
output (I/O) modules. The modules listed in the table below may be used.
These modules function like switches; they do not supply a voltage.
(See Appendix A.)
Connect I/O wiring to the correct terminal blocks. When using DC modules,
observe the polarity of the connections illustrated on the circuit board.
I/O Module Wiring
Available I/O Modules for use with AL5010
Description Color Rating Current Range Part Number
1000056135 DC Input Module white 3.3 to 32 VDC 32 mA
1000056136 DC Output Module red 3 to 60 VDC 3 A max. *
1000056137 AC Output Module black 12 to 42 VACPeak 3 A max. *
NOTE: Relay modules
are only for connection to SELV, LPS power source and shall
also meet the requirements for Class 2.
* Derate 33mA/deg above 25C.
See also: Drawing 113490 in Appendix F.
04-AL5010_Electrical_Installation_R20.doc Accu-Sort Systems, Inc.